Lincoln Electric IM579 manual Operation

Page 23

B-12

B-12

OPERATION

When a pair of welding procedures are recalled from memory, the display window will show the procedure description, wire feed speed, and the preset voltage or arc length trim of the LAST pro- cedure welded with.

With this overlay in place, the wire feed speed and the preset voltage or arc length trim can be changed from the wire feeder. The new values will replace the previous values and become a perma- nent part of the procedure.

If limits have been set on the wire feed speed, volt- age or arc length trim of the selected procedures, these limits will be active when this overlay is in place. They cannot be overridden from this over- lay.

3.THE PROGRAM LIST: The PROGRAM LIST block in the center of this overlay provides a convenient place to record a brief description of each welding procedure stored in memory. A “Dry Erase” mark- er should be used for this purpose.

4.DISPLAY RECALL KEY: To view other information about the active procedure, press the DISPLAY RECALL key. The display window will show the procedure description and gas type of the active procedure for as long as the key is held depressed. When the key is released, the wire size, material type, and process descriptions dis- play for a few seconds.

5.HIGH TEMPERATURE LIGHT: The high tempera- ture light comes on when the internal machine temperature exceeds the allowed limit. Output is disabled until the machine cools down and the high temperature light goes out.

6.MEMORY LIGHTS: A memory light is on when its corresponding memory is selected. This tells you what memory location is active at any given time.

POWER WAVE 450

Image 23
Contents Safety Depends on You Invertec Power WavetmFumes and Gases can be dangerous SafetyElectric Shock can kill ARC Rays can burnFor Electrically pow- ered equipment Welding Sparks can cause fire or explosionCylinder may explode if damaged May be dangerous For Engine powered equipmentElectric and Magnetic Fields Précautions DE Sûreté Please Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Pulse Pulse and Background Current Range Voltage Range InstallationTechnical Specifications Power Wave Select Suitable Location Safety PrecautionsHigh Frequency Precautions Input ConnectionsGround Connections Input Voltage Reconnect ProcedureInput Power Connections Input Fuse and Supply Wire ConsiderationsWater Cooler Connections Wire Feeder ConnectionsOutput Connections Work and Electrode Cable ConnectionsFumes and Gases can be Safety InstructionsOperation Operating InstructionsSave process information if desired Select your process informationRecommended Processes Design Features and AdvantagesOperational Features and Controls Synergic WeldingCase Front Controls Controls and SettingsOverview Installing AN OverlayOperating Overlays Name Overlay TypesOverlay Overlay ID Number = PULSE, GMAW, FCAW, and STICK/TIG Process Selection OverlayOperation Then Memory Location # is Empty Weld from Memory OverlayFigure B.6 Weld from MEMORY, Dual Procedure Overlay Weld from MEMORY, Dual Procedure OverlayOperation Position Procedure Dual Wire FEEDERS, Dual Procedure Overlay OptionalRecall from Memory KEY Memory Location Numbers Limits Overlay OptionalOperation Figure B.9 Setup Overlay Setup OverlayNegative Polarity Voltage Sensing Wire Feeder Setup DescriptionPositive Polarity Voltage Sensing Table B.1 Positive Voltage Sensing OptionsPositive Voltage Sensing Polarity STICK/TIG Procedures Overview of Welding ProceduresFlux Cored ARC Welding Fcaw and Gmaw Procedures Pulse ProceduresExplanation of Table B.3 Pulse processes Pulse WeldingOver Current Protection Overload ProtectionThermal Protection Guns and Cables AccessoriesOPTIONS/ACCESSORIES Wire Feeder SetupWater Cooler Usage Input Filter Capacitor DIS Charge Procedure MaintenanceRoutine and Periodic Maintenance Figure D.1 Resistor Locations Locate the #9 and #12 terminals, identified by Discharge labels, on each of the four SwitchPreventive Maintenance Figure D.4 General Component Locations HOW to USE Troubleshooting Guide TroubleshootingSists, contact your local Lincoln Troubleshooting GuideAuthorized Field Service Facility Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas Wiring Diagram Wiring DiagramsNeed Welding Training? How To Read Shop DrawingsNew Lessons in Arc Welding Precaucion Aviso DE Limited Warranty