Lincoln Electric IM10031-A Installation, Technical Specifications LN-25 PRO K2613-1, K2613-2

Page 10

A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS – LN-25™ PRO (K2613-1, K2613-2)

INPUT VOLTAGE and CURRENT

INPUT VOLTAGE ± 10%

INPUT AMPERES

15-110 VDC

4A

RATED OUTPUT @ 104°F (40°C)

DUTY CYCLE

 

 

 

 

 

INPUT AMPERES

 

 

 

 

 

 

 

 

 

 

 

 

 

60% rating

 

 

 

 

450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100% rating

 

 

 

 

325

 

 

 

 

 

 

 

 

 

 

GEARING - WIRE FEED

SPEED RANGE-WIRE SIzE

GEARING

 

 

GMAW

 

 

FCAW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WFS RANGE

 

WIRE SIzES

 

WFS RANGE

 

 

WIRE SIzES

 

 

 

 

 

 

 

 

 

Extra torque

30 – 400 ipm

 

.023 – 1/16"

 

30 – 400 ipm

 

 

.030 - 3/32”

K2613-2

(0.8 – 10.1m/min)

 

(0.6 – 1.6mm)

 

(0.8 – 10.1m/min)

 

(10.3 – 2.4mm)

 

 

 

 

 

 

 

 

 

Standard Speed

50 – 700 ipm

 

.023 – 1/16"

 

50 – 700 ipm

 

.030 - 5/64

 

K2613-1

(1.3 – 17.7m/min)

 

(0.6 – 1.6mm)

 

(1.3 – 17.7m/min)

 

 

(0.8 - 2.0mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

HEIGHT

 

 

 

WIDTH

 

 

DEPTH

 

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

14.8 Inches

 

 

8.7 Inches

 

 

22.2 Inches

 

36 lbs

(376 mm)

 

 

( 221 mm)

 

 

(589 mm)

 

(16 kg)

Handle folded down

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE RANGE

 

 

 

OPERATION:

 

 

 

 

-40°F to 104°F

(-40°C to 40°C)

 

 

 

STORAGE:

 

 

 

 

-40°F to 185°F

(-40°C to 85°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LN-25™ PRO

Image 10
Contents LN-25 Tmpro Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcElectromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply Please Examine Carton and Equipment For Damage Immediately ViiOn-Line Product Registration TAbLE of Contents Wire SIzES InstallationTechnical Specifications LN-25 PRO K2613-1, K2613-2 LN-25 PROHigh Frequency Protection Safety PrecautionsLocation Weld CAbLE SIzEWire Feeder 3INSTALLATIONA-3Power Source Analog Control CAbLE K1797-xxCAbLE Connections Function Pin WiringShielding GAS Connection Procedure to Install Drive Rolls and Wire Guides Wire Drive ConfigurationChanging the GUN Receiver bUSHING GUN Connection Pressure ARM AdjustmentLoading Spools of Wire Fe, CrNiAcross the ARC SET-UPS Power Source to LN-25 PRODescription Figure A.7 9INSTALLATIONA-9 Figure A.9Safety Precautions OperationGeneral Description Case Front Controls See Figure b.1 Figure b.1Minimum Arc Volts Maximum WFS Wire Feed Speed KNObWire Feed Speed, CV Operation Extra TorquePolarity LED Internal Controls Figure b.2Cold Feed PUSHbUTTON Step Trigger Interlock SwitchInternal Controls Description Step TriggerConstant Current Wire Welding Figure b-3Itemdescription Rear ControlsFlow Meter POWER-UP SequenceGAS Purge PUSHbUTTON Liter/MinDrive Roll Kits AccessoriesFactory Installed Equipment Electrode SIzEOn at all times Accessories K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT Periodic Maintenance MaintenanceRoutine Maintenance CALIbRATION SpecificationModel gearing Wire Feed Speed ValidationTo change the wire feed speed calibration See Figure D.2 BOARD LN-25 PROTROUbLESHOOTING Electric Shock can killPOSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLESHOOTING Diagrams Enhanced DiagramDimension Print Precaucion Warnung