OPERATION | ||
|
|
|
3.
4.WORK SENSE LEAD
5.THERMAL LED, MOTOR OVERLOAD
The thermal light illuminates when the wire drive motor draws too much current. If the thermal light illuminates, the wire drive will automatically shutdown for up to 30 seconds to allow the motor to cool. To
start welding again, release the gun trigger, inspect the gun cable, liner (and conduit). Clean and make repairs as necessary. Start welding again when the problem has been safely resolved.
For best results, keep the gun cable and conduit as straight as possible. Perform regular maintenance and cleaning on the gun liner, conduit and gun. Always use quality electrode, such as
6.POLARITY LED
The Polarity LED
lights when the wire feeder is connected
for positive polarity.
Use the polarity LED to verify the
wire feeder is connected for the proper polarity.