Lincoln Electric IM10031-A manual Safety Precautions, Location, High Frequency Protection

Page 11

A-2

INSTALLATION

A-2

 

 

 

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK CAN KILL.

• Turn the input power OFF at the disconnect switch or fuse box before attempting to connect or disconnect input power lines, out- put cables or control cables.

Only qualified personnel should perform this installation.

Do not touch metal portions of the work clip when the welding power source is on.

Do not attach the work clip to the wire feeder.

Connect the work clip directly to the work, as close as possible to the welding arc.

Turn power off at the welding power source before disconnecting the work clip from the work.

Only use on power sources with open circuit voltages less than 110 VDC.

------------------------------------------------------------------------

LOCATION

For best wire feeding performance, place the LN- 25™ PRO on a stable and dry surface. Keep the wire feeder in a vertical position. Do not operate the wire feeder on an angled surface of more than 15 degrees.

Do not submerge the LN-25™ PRO.

The LN-25™ PRO is rated IP23 and is suitable for outdoor use.

The handle of the LN-25™ PRO is intended for moving the wire feeder about the work place only.

When suspending a wire feeder, insulate the hanging device from the wire feeder enclosure.

HIGH FREQUENCY PROTECTION

CAUTION

Locate the LN-25™ PRO away from radio controlled machinery. The normal operation of the LN-25™ PRO may adversely affect the operation of RF con- trolled equipment, which may result in bodily injury or damage to the equipment.

----------------------------------------------------------------------------

WELD CAbLE SIzE

Table A.1 located below are copper cable sizes rec- ommended for different currents and duty cycles. Lengths stipulated are the distance from the welder to work and back to the welder again. Cable sizes are increased for greater lengths primarily for the purpose of minimizing cable drop.

TAbLE A.1

RECOMMENDED CAbLE SIzES (RUbbER COVERED COPPER - RATED 167°F or 75°C)**

 

 

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES

AMPERES

PERCENT

 

 

 

 

 

 

DUTY

0 to 50Ft.

50 to 100Ft.

100 to 150 Ft.

150 to 200 Ft.

200 to 250 Ft.

 

CYCLE

(0 to15m)

(15 to 30m)

(30 to 46m)

(46 to 61m)

(61 to 76m)

 

 

 

 

 

 

 

 

 

 

 

 

 

200

60

2

2

2

1

1/0

200

100

2

2

2

1

1/0

225

20

4 or 5

3

2

1

1/0

225

40 & 30

3

3

2

1

1/0

250

30

3

3

2

1

1/0

250

40

2

2

1

1

1/0

250

60

1

1

1

1

1/0

250

100

1

1

1

1

1/0

300

60

1

1

1

1/0

2/0

325

100

2/0

2/0

2/0

2/0

3/0

350

60

1/0

1/0

2/0

2/0

3/0

400

60

2/0

2/0

2/0

3/0

4/0

400

100

3/0

3/0

3/0

3/0

4/0

500

60

2/0

2/0

3/0

3/0

4/0

 

 

 

 

 

 

 

**Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables larger than recommended, or cables rated higher than 167°F(75°C).

LN-25™ PRO

Image 11
Contents LN-25 Tmpro California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply On-Line Product Registration Vii Please Examine Carton and Equipment For Damage Immediately TAbLE of Contents LN-25 PRO InstallationTechnical Specifications LN-25 PRO K2613-1, K2613-2 Wire SIzESWeld CAbLE SIzE Safety PrecautionsLocation High Frequency ProtectionAnalog Control CAbLE K1797-xx 3INSTALLATIONA-3Power Source Wire FeederShielding GAS Connection Function Pin WiringCAbLE Connections Changing the GUN Receiver bUSHING Wire Drive ConfigurationProcedure to Install Drive Rolls and Wire Guides Fe, CrNi Pressure ARM AdjustmentLoading Spools of Wire GUN ConnectionDescription Power Source to LN-25 PROAcross the ARC SET-UPS Figure A.7 Figure A.9 9INSTALLATIONA-9Operation Safety PrecautionsGeneral Description Figure b.1 Case Front Controls See Figure b.1Extra Torque Wire Feed Speed KNObWire Feed Speed, CV Operation Minimum Arc Volts Maximum WFSPolarity LED Figure b.2 Internal ControlsStep Trigger Step Trigger Interlock SwitchInternal Controls Description Cold Feed PUSHbUTTONFigure b-3 Constant Current Wire WeldingRear Controls ItemdescriptionLiter/Min POWER-UP SequenceGAS Purge PUSHbUTTON Flow MeterElectrode SIzE AccessoriesFactory Installed Equipment Drive Roll KitsOn at all times Accessories K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT CALIbRATION Specification MaintenanceRoutine Maintenance Periodic MaintenanceBOARD LN-25 PRO Wire Feed Speed ValidationTo change the wire feed speed calibration See Figure D.2 Model gearingElectric Shock can kill TROUbLESHOOTINGCause Recommended Course of Action PRObLEMSSymptoms POSSIbLETROUbLESHOOTING Enhanced Diagram DiagramsDimension Print Precaucion Warnung