K541 - Magnum 400 Short Neck GMAW gun and cable assemblies are rated 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K598 - Magnum 550 GMAW gun and cable assemblies are rated 550 amps, 60% duty cycle . (Consult sales specifications for appropriate models).

K206* - Innershield Linconditioner gun and cable assemblies are rated 350 amps, 60% duty cycle. Maximum size for Synergic 7F Wire Feed unit is 5/64” (2.0 mm). Not recommended for Synergic 7FH Wire Feed unit. (Consult sales specifications for appropriate models).

K289* - Innershield Linconditioner gun and cable assemblies are rated 500 amps, 60% duty cycle. Maximum size for Synergic 7F Wire Feed unit is 5/64” (2.0 mm). Not recommended for Synergic 7FH Wire Feed unit. (Consult sales specifications for appropriate models).

K309* - Innershield Linconditioner gun and cable assemblies are rated 250 amps, 60% duty cycle. Maximum size for Synergic 7F Wire Feed unit is 5/64” (2.0 mm). Not recommended for Synergic 7FH Wire Feed unit. (Consult sales specifications for appropriate models).

The following Lincoln gun and cable assemblies are equipped with a Fast-Mate™ connector. They can be used with Synergic 7F Wire Feed unit by installing a K489-2 Fast-Mate adapter kit.

K684 - Magnum “Super Cool” FM water cooled GMAW gun and cable assemblies are rated 450 amps, 100% duty cycle (CO 2 ) . (Consult sales specifications for appropriate models).

K498 - Magnum 200 FM GMAW gun and cable assemblies are rated for 200 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K534 - Magnum 250L FM GMAW gun and cable assemblies are rated for 250 amps, 30% duty cycle. (Consult sales specifications for appropriate models).

K478 - Magnum 300 FM GMAW gun and cable assemblies are rated for 300 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K479 - Magnum 400 FM GMAW gun and cable assemblies are rated for 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K556 * - GMAW process Magnum 400XA X - TRACTOR gun and cable assemblies are rated at 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K566 * - GMAW process Magnum 250XA X - TRACTOR gun and cable assemblies are rated 250 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

*K179 type vacuum unit not recommended for use with Synergic 7F.

MISCELLANEOUS OPTIONS:

K682 Water Connection Kit - Includes water cooled gun tube fittings and self - sealing outlet and inlet quick - connectors for mounting onto the Synergic 7F Wire Drive mounting bracket.

K659-1 - (Gas Guard Regulator) Adjustable flow regulator with removable adjustor key for CO2 and Argon blend gases.

Mounts onto Wire Drive gas inlet, and reduces gas waste and arc start “blow” by reducing surge caused by excess pressure in supply hose.

K683-1 - (Dual Procedure Switch) Kit includes gun switch and mountings for Lincoln Innershield and Magnum guns with 15 ft (4.6 m) control cable and 3-pin plug.

11

Image 11
Contents Synergic 7F and Synergic 7FH Apr. ‘93 ARC Welding can be hazardousMar. ‘93 Cylinder may explode if damagedSûreté Pour Soudage a L’Arc Précautions DE SûretéTable of Contents Please Examine Carton and Equipment For Damage Immediately Recommended Processes and Equipment Standard FeaturesWire Feed Features General DescriptionControl Features Top to bottom starting from Causes mode lights to sequenceY P a D a N D D I S P L a Y Description Keypad Seven key, membrane type with snap tactile feelDrive Roll and Guide Tube Kits Optional FeaturesMiscellaneous Options Model Specifications for Synergic 7F Synergic 7FHType K678-1 K679-1 K679-2 Wire Speed Range Safety Precautions InstallationAluminum Wire Sizes Procedure to Install Drive Roll and Guide TubesWire Feed Drive Roll and Guide Tube Kits Steel Wire Sizes RollInnershield Guns Gun and Cable Assemblies with Standard L. E. ConnectionsGun Cable Connection Gmaw GunsGmaw Shielding Gas Gun Cable Connections Wire Feeder to GunSynergic 7F Water Connections for Water-Cooled Guns 60% Duty Cycle Up to 100 ft Length 30m Electrical InstallationWork Cable CurrentInstallation section for instructions Optional Features InstallationK648 or K649 Input Cable Assembly See Electrical Current indicated position Power-Down SaveOperation Keys Mode Selection Operating InstructionsDisplay Control Keys Run-In Selection Acceleration SelectionSelection of English or Metric Speed Display Units To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter Step Trigger Mode SelectionFeeding Electrode and Brake Adjustment Feeding Electrode To Mount a 50-60lb 22.7-27.2kg CoilGas Guard Regulator Setting Optional K659-1 Wire Loading of 13-14lb 6kg Innershield CoilsIdle Roll Pressure Setting Making a Weld Wire Reel ChangingWire Feed Overload Protection Explanation of Prompting Error Messages Avoiding Wire Feeding Problems MaintenanceRoutine Maintenance Wire Reel Mounting 50 22.7kg and 60lb 27.2kg CoilsTroubleshooting Guide Communications in control cable ProblemsProblems Gun connector Trigger sockets on gun connector For continuity Refer to WiringWiring & connections When trigger is closed and noProblems Cold Feed key does not turn Defective keypad or Display PC Troubleshooting information. See Dual Procedure is not Gun has not been selected atWith the remote switch open. If a For replacing PC boards Problems with serialHXX Switch Requirements Procedure for Replacing PC Boards Electric Shock can killInside I N InputControl BOX Dimension Print Wire Feed Unit Dimension Print $700.00 How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung