PROBLEMS
|
|
|
|
|
|
|
|
|
|
| PROBLEM |
|
| POSSIBLE CAUSE |
|
| WHAT TO DO |
|
|
|
|
|
|
|
|
|
|
|
|
| 14. Cold Feed key does not turn |
|
| a. Defective keypad or Display PC |
|
| a. Check continuity between sockets 4 |
|
|
| on wire feed motor but trigger |
|
| board is defective. |
|
| and 1 of keypad connector when |
|
|
| closure does. |
|
|
|
|
| Cold Feed key is closed. If not, |
|
|
|
|
|
|
|
|
| then replace keypad, otherwise, |
|
|
|
|
|
|
|
|
| replace Display PC board. (See |
|
|
|
|
|
|
|
|
| Procedure for Replacing PC |
|
|
|
|
|
|
|
|
| boards). |
|
|
|
|
|
|
|
|
|
|
|
|
| 15. Display and/or indicator lights |
|
| \a. Defective keypad or Display PC |
|
| a. Ring out keypad. Replace if |
|
|
| do not change when the arrow |
|
| board. |
|
| defective. If not, then replace |
|
|
| or select keys are pressed. |
|
|
|
|
| Display PC board. (See Procedure |
|
|
|
|
|
|
|
|
| for Replacing PC boards.) |
|
|
|
|
|
|
|
|
|
|
|
|
| 16. Display does not change when |
|
| a. Make sure that the function |
|
| a. Press the function key to light the |
|
|
| WFS and/or Volts/Trim knobs |
|
| select key has been pressed to |
|
| LED next to the display function that |
|
|
| are turned. |
|
| light the LED corresponding to |
|
| corresponds with the knob to be |
|
|
|
|
|
| the Volts/Trim or WFS display |
|
| adjusted. |
|
|
|
|
|
| depending on which knob you |
|
|
|
|
|
|
|
|
| are attempting to adjust. |
|
|
|
|
|
|
|
|
| b. Broken harness wire(s) or |
|
| b. Check harness connections to |
|
|
|
|
|
| harness disconnected from |
|
| encoder and control boards and |
|
|
|
|
|
| encoder boards(s) or control |
|
| continuity between corresponding |
|
|
|
|
|
| board. |
|
| harness leads in P2 and P17. |
|
|
|
|
|
|
|
|
| (Refer to wiring diagram). |
|
|
|
|
|
| c. Defective Encoder boards and/or |
|
| c. If b. is not the problem and neither |
|
|
|
|
|
| control board. |
|
| the WFS or Volts/Trim knobs are |
|
|
|
|
|
|
|
|
| properly adjusting then replace the |
|
|
|
|
|
|
|
|
| control board. If one of the two |
|
|
|
|
|
|
|
|
| knobs are properly adjusting, plug |
|
|
|
|
|
|
|
|
| the P17 harness from the working |
|
|
|
|
|
|
|
|
| board into the nonfunctional board. |
|
|
|
|
|
|
|
|
| If the previously nonfunctional board |
|
|
|
|
|
|
|
|
| is now working, replace the control |
|
|
|
|
|
|
|
|
| board. Otherwise replace the |
|
|
|
|
|
|
|
|
| nonfunctional encoder board. (See |
|
|
|
|
|
|
|
|
| procedure for replacing PC boards). |
|
|
|
|
|
|
|
|
|
|
|
|
| 17. Display is blank. |
|
| a. Power source is OFF. |
|
| a. Turn ON power source. |
|
|
|
|
|
| b. Feeder supply fuse or circuit |
|
| b. Check input cable and feeder unit |
|
|
|
|
|
| breaker at power source is blown |
|
| for short in 41 and 42 circuit. Check |
|
|
|
|
|
| or tripped. |
|
| for shorted motor. Replace fuse or |
|
|
|
|
|
|
|
|
| reset circuit breaker. |
|
|
|
|
|
| c. Display or Control PC board is |
|
| c. Observe LED mounted on Control |
|
|
|
|
|
| bad. |
|
| PC board. It should blink on and off |
|
|
|
|
|
|
|
|
| at a controlled rate of 1 second ON |
|
|
|
|
|
|
|
|
| and 1 second OFF. If so, then |
|
|
|
|
|
|
|
|
| replace Display PC board. If not, |
|
|
|
|
|
|
|
|
| replace Control PC board. (See |
|
|
|
|
|
|
|
|
| Procedure for Replacing PC |
|
|
|
|
|
|
|
|
| boards.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
– 33 –