Lincoln Electric 7FH manual Display Control Keys, 95 MAR

Page 20

Display Control Keys

synergically set by the power source for the process and weld Feed Speed being

VVOLTS / TRIM

RUN-IN

WFS

The function select, timer/crater select, arrow keys and rotational encoders all effect the display. Pressing the function select key will cause a function to be displayed. Pressing the timer/crater select key will cause a timer or crater feed speed to be displayed. Whichever is pressed last is the one that will be displayed since they cannot be displayed simultaneously. Only one function or timer indicator light can be on at one time and therefore it always indicates what is being displayed. The arrow keys allow you to adjust the Run-in speed timer or crater speed being displayed. The encoder knobs allow rotational adjustment of weld wire feed speed and Arc Volts/Trim.

Function Select key enables operator to choose which function will be displayed as indicated by the appropriate light. Pressing the key causes lights to sequence (top to bottom) starting from the current indicated position. If a timer or crater speed is being displayed when the Function Select key is pressed, then the indicator light of the last function selected before the timer/crater key was chosen will come on and become the starting point for the sequencing.

Top Light - indicates Voltmeter Function has been selected and arc voltage (in volts) will be displayed along with electrode polarity when the trigger has been pressed . When the trigger is not pressed, this will serve as a preset voltage/trim function and the preset voltage/trim will be displayed. The top light “blinks” when arc voltage is being displayed and stays lit when preset voltage/trim is displayed. The last welding voltage displayed before the weld is terminated, will continue to be displayed for 5 seconds after welding to permit operator monitoring.

The preset voltage/trim may be adjusted, using the Volts/Trim encoder knob. The synergic preset voltage/trim level may be adjusted within the range

used.

The power source automatically determines whether preset voltage or percent trim will be displayed. Preset voltage is indicated by one digit only to the right of the decimal point, while percent trim always displays two digits to the right of the decimal point.

Middle Light - Indicates Run - In Speed Function has been selected and the Run-In speed setting is being displayed in IPM or m/m (see section for English or Metric display).

As shipped these models are setup for min. rated fixed Run-In speed with display function deactivated. They may be user-selected to activate or deactivate adjustable Run-In display. (See section for selection of Run-In and resetting fixed Run-In speed).

Wire will be fed at the Run-In speed rate until arc current begins to flow. Once arc current flows, wire will be fed at the Weld speed rate . Decreasing Run-In speed below its lower limit (using the down arrow key) causes the display to read “- - -”. This indicates that the Run-In speed will be kept the same as the weld speed setting. You can reset a different Run- In speed simply by pressing the up arrow key.

The Run-In speed will also be the same as the weld speed setting if rapid restrike welding applications are used, where the arc is restruck in a fraction of a second after the previous welding arc was stopped.

Bottom Light - Indicates Weld Feed Speed (WFS) Function has been selected and the weld speed setting is being displayed in IPM or M/M (see section for English or Metric speed display). The range of Weld Feed Speed is synergically set by the power source for the process being used, and is adjustable using the Wire Feed Speed encoder knob on the front of the Synergic 7F Control.

95 MAR

20

Image 20
Contents Synergic 7F and Synergic 7FH ARC Welding can be hazardous Apr. ‘93Cylinder may explode if damaged Mar. ‘93Précautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Please Examine Carton and Equipment For Damage Immediately Standard Features Wire Feed FeaturesGeneral Description Recommended Processes and EquipmentControl Features Causes mode lights to sequence Y P a D a N D D I S P L a Y DescriptionKeypad Seven key, membrane type with snap tactile feel Top to bottom starting fromOptional Features Drive Roll and Guide Tube KitsMiscellaneous Options Model Specifications for Synergic 7F Synergic 7FHType K678-1 K679-1 K679-2 Wire Speed Range Installation Safety PrecautionsProcedure to Install Drive Roll and Guide Tubes Wire Feed Drive Roll and Guide Tube KitsSteel Wire Sizes Roll Aluminum Wire SizesGun and Cable Assemblies with Standard L. E. Connections Gun Cable ConnectionGmaw Guns Innershield GunsGmaw Shielding Gas Gun Cable Connections Wire Feeder to GunSynergic 7F Water Connections for Water-Cooled Guns Electrical Installation Work CableCurrent 60% Duty Cycle Up to 100 ft Length 30mInstallation section for instructions Optional Features InstallationK648 or K649 Input Cable Assembly See Electrical Power-Down Save Operation Keys Mode SelectionOperating Instructions Current indicated positionDisplay Control Keys Run-In Selection Acceleration SelectionSelection of English or Metric Speed Display Units To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter Step Trigger Mode SelectionFeeding Electrode and Brake Adjustment To Mount a 50-60lb 22.7-27.2kg Coil Feeding ElectrodeGas Guard Regulator Setting Optional K659-1 Wire Loading of 13-14lb 6kg Innershield CoilsIdle Roll Pressure Setting Making a Weld Wire Reel ChangingWire Feed Overload Protection Explanation of Prompting Error Messages Maintenance Routine MaintenanceWire Reel Mounting 50 22.7kg and 60lb 27.2kg Coils Avoiding Wire Feeding ProblemsTroubleshooting Guide Problems Communications in control cableProblems For continuity Refer to Wiring Wiring & connectionsWhen trigger is closed and no Gun connector Trigger sockets on gun connectorProblems Cold Feed key does not turn Defective keypad or Display PC Dual Procedure is not Gun has not been selected at With the remote switch open. If aFor replacing PC boards Problems with serial Troubleshooting information. SeeHXX Procedure for Replacing PC Boards Electric Shock can kill Switch RequirementsInside Input I NControl BOX Dimension Print Wire Feed Unit Dimension Print How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung