Lincoln Electric 7FH Acceleration Selection, Selection of English or Metric Speed Display Units

Page 21

Timer/Crater Select - key enables operator to choose crater speed, spot

PREFLOW

POSTFLOW

1

2

 

or gas timers as indicated by the

 

appropriate light. Pressing key causes

 

 

 

 

 

 

 

CRATER lights to sequence (left to right, top to

 

 

 

 

bottom) starting from the current

 

 

 

 

 

 

 

 

SPOT indicated position. Any parameter not

 

 

 

 

available in the mode selected is

 

 

 

 

skipped over. If a function is being

 

 

 

 

displayed when the Timer/Crater Select

 

 

 

 

 

 

 

 

key is pressed, then the light of the last

 

 

 

 

 

 

 

 

parameter selected before the function

 

 

 

 

was chosen will come on and become

 

 

 

 

the starting point for the sequencing.

 

 

 

 

Top Left Light - indicates preflow time

 

 

 

 

is being displayed in seconds. This is

GAS PURGE

V VOLTS / TRIM

RUN-IN

WFS

Acceleration Selection

Pressing both the Gas Purge key and then function select key at the same time causes the acceleration setting to be displayed. The display will indicate “A-X” where X will be a number from 1 through 5 with 5 being the fastest acceleration. This number can be adjusted using the arrow keys. To exit this function, press both these keys again or press any other key except the arrow keys.

the time the shielding gas flows before

the wire feed and power source are

activated.

Top Right Light - indicates postflow

time is being displayed in seconds.

This is the time the shielding gas flows

after the wire feed and power source

are deactivated.

Middle Light - indicates that crater feed

speed is being displayed. Crater speed

is only available when 4-step trigger

with crater fill is selected. It is activated

by Step 3 and deactivated by Step 4 of

the 4 - step sequence . (See 4 - step

trigger mode selection section).

Bottom Light - indicates spot on time is

being displayed in seconds.

NOTE: if unit is not in spot mode then

this light will be skipped over in the

GAS PURGE

PREFLOW POSTFLOW

12

CRATER

SPOT

Selection of English or Metric Speed Display Units

Pressing both the Gas Purge key and then timer select key at the same time causes the speed display units to toggle between IPM (no decimal point displayed) and m/m (a decimal point displayed). If the speed display units were IPM, then they will change to m/m. If the speed display units were m/m, then they will change to IPM. If the display is showing the volts/trim or one of the timers when the keys are pressed, the display will be changed to weld speed to indicate the selected speed display units.

selection sequence.

Increase Arrow - key increases the

setting of the parameter selected to be

displayed, except Wire Feed Speed and

Volts/Trim which are controlled by the

encoder knobs.

Decrease Arrow - key decreases the

setting of the parameter selected to be

displayed, except Wire Feed Speed and

Volts/Trim which are controlled by the

encoder knobs.

Arrow key adjustments use the

“Accelerating Digit” method for setting

changes, where holding the arrow key

causes setting change rate to

accelerate from slow to fast. Releasing

arrow key resets to slow setting

change.

GAS PURGE

COLD FEED

Run-In Selection

Pressing both the Gas Purge and Cold Feed keys at the same time causes Run-In function to toggle on or off, as indicated by the Run-In indicator light turning on or remaining off in the function select sequence.

As shipped, the Run-In function is off with a fixed setting of min. rated speed. Therefore, the Run-In indicator light will not sequence with the function select key, but the fixed setting will still be used for actual Run-In speed.

Activation of adjustable Run-In speed using the above dual key press, will permit Run-In speed to be adjusted with the arrow keys and the Run-In indicator light will return to function key sequence. Re-pressing the above dual key again removes the Run-In light from the function key sequence, but replaces the fixed Run - In speed with the adjusted Run-in speed setting, until readjusted.

95 MAR

21

Image 21
Contents Synergic 7F and Synergic 7FH Apr. ‘93 ARC Welding can be hazardousMar. ‘93 Cylinder may explode if damagedSûreté Pour Soudage a L’Arc Précautions DE SûretéTable of Contents Please Examine Carton and Equipment For Damage Immediately Wire Feed Features Standard FeaturesGeneral Description Recommended Processes and EquipmentControl Features Y P a D a N D D I S P L a Y Description Causes mode lights to sequenceKeypad Seven key, membrane type with snap tactile feel Top to bottom starting fromDrive Roll and Guide Tube Kits Optional FeaturesMiscellaneous Options Specifications for Synergic 7F Synergic 7FH Type K678-1 K679-1 K679-2 Wire Speed RangeModel Safety Precautions InstallationWire Feed Drive Roll and Guide Tube Kits Procedure to Install Drive Roll and Guide TubesSteel Wire Sizes Roll Aluminum Wire SizesGun Cable Connection Gun and Cable Assemblies with Standard L. E. ConnectionsGmaw Guns Innershield GunsGun Cable Connections Wire Feeder to Gun Synergic 7F Water Connections for Water-Cooled GunsGmaw Shielding Gas Work Cable Electrical InstallationCurrent 60% Duty Cycle Up to 100 ft Length 30mOptional Features Installation K648 or K649 Input Cable Assembly See ElectricalInstallation section for instructions Operation Keys Mode Selection Power-Down SaveOperating Instructions Current indicated positionDisplay Control Keys Acceleration Selection Selection of English or Metric Speed Display UnitsRun-In Selection Step Trigger Mode Selection Feeding Electrode and Brake AdjustmentTo Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter Feeding Electrode To Mount a 50-60lb 22.7-27.2kg CoilWire Loading of 13-14lb 6kg Innershield Coils Idle Roll Pressure SettingGas Guard Regulator Setting Optional K659-1 Wire Reel Changing Wire Feed Overload ProtectionMaking a Weld Explanation of Prompting Error Messages Routine Maintenance MaintenanceWire Reel Mounting 50 22.7kg and 60lb 27.2kg Coils Avoiding Wire Feeding ProblemsTroubleshooting Guide Communications in control cable ProblemsProblems Wiring & connections For continuity Refer to WiringWhen trigger is closed and no Gun connector Trigger sockets on gun connectorProblems Cold Feed key does not turn Defective keypad or Display PC With the remote switch open. If a Dual Procedure is not Gun has not been selected atFor replacing PC boards Problems with serial Troubleshooting information. SeeHXX Switch Requirements Procedure for Replacing PC Boards Electric Shock can killInside I N InputControl BOX Dimension Print Wire Feed Unit Dimension Print New Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? $700.00Precaucion Warnung