Lincoln Electric manual Specifications for Synergic 7F Synergic 7FH, Model

Page 12

SPECIFICATIONS FOR SYNERGIC 7F

AND SYNERGIC 7FH

 

CONTROL

WIRE FEED - (4 - ROLL)

 

 

 

 

 

 

 

Model

SYNERGIC 7F

SYNERGIC 7F

SYNERGIC 7FH

 

 

 

 

 

 

Type

K678-1

K679-1

K679-2

 

 

 

 

 

 

 

 

Wire Speed Range:

 

 

 

 

 

 

IPM

 

50 - 770

80 - 1200

 

M/M

 

1.25 - 19.5

2.00

-

30.5

 

 

 

 

 

 

 

 

Wire Size Capabilities:

 

 

 

 

 

 

Solid Electrodes

.025 - 1/16”

.025 - 1/16”

.025

-

.045”

 

 

0.6 - 1.6mm

0.6 - 1.6mm

0.6 - 1.2mm

 

Cored Electrodes

.045 - 3/32”

.045 - 3/32”

.045”

 

 

1.2 - 2.4mm

1.2 - 2.4mm

1.2mm

 

 

 

 

 

 

 

 

Input Power:

40-42 V ± 10%

 

 

 

 

 

 

50/60 Hz

 

 

 

 

 

 

4.0 Amps

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Rating:

 

 

 

 

 

 

Operating

 

-20°C to +40°C

 

 

 

 

Storage

 

-40°C to +40°C

 

 

 

 

 

 

 

 

 

 

 

Dimensions:

 

 

 

 

 

 

Height

13.31” (338.1 mm)

11.25” (285.8 mm)

 

 

 

Width

10.32” (262.1 mm)

7.16” (181.9 mm)

 

 

 

Depth

6.16” (156.5 mm)

8.06” (204.7 mm)

 

 

 

 

 

 

 

 

 

 

Weight

13.25 lbs (6.0 Kg)

16.5 lbs (7.5 Kg)

 

 

 

 

 

 

 

 

 

 

12

Image 12
Contents Synergic 7F and Synergic 7FH ARC Welding can be hazardous Apr. ‘93Cylinder may explode if damaged Mar. ‘93Précautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Please Examine Carton and Equipment For Damage Immediately Standard Features Wire Feed FeaturesGeneral Description Recommended Processes and EquipmentControl Features Causes mode lights to sequence Y P a D a N D D I S P L a Y DescriptionKeypad Seven key, membrane type with snap tactile feel Top to bottom starting fromOptional Features Drive Roll and Guide Tube KitsMiscellaneous Options Specifications for Synergic 7F Synergic 7FH Type K678-1 K679-1 K679-2 Wire Speed RangeModel Installation Safety PrecautionsProcedure to Install Drive Roll and Guide Tubes Wire Feed Drive Roll and Guide Tube KitsSteel Wire Sizes Roll Aluminum Wire SizesGun and Cable Assemblies with Standard L. E. Connections Gun Cable ConnectionGmaw Guns Innershield GunsGun Cable Connections Wire Feeder to Gun Synergic 7F Water Connections for Water-Cooled GunsGmaw Shielding Gas Electrical Installation Work CableCurrent 60% Duty Cycle Up to 100 ft Length 30mOptional Features Installation K648 or K649 Input Cable Assembly See ElectricalInstallation section for instructions Power-Down Save Operation Keys Mode SelectionOperating Instructions Current indicated positionDisplay Control Keys Acceleration Selection Selection of English or Metric Speed Display UnitsRun-In Selection Step Trigger Mode Selection Feeding Electrode and Brake AdjustmentTo Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter To Mount a 50-60lb 22.7-27.2kg Coil Feeding ElectrodeWire Loading of 13-14lb 6kg Innershield Coils Idle Roll Pressure SettingGas Guard Regulator Setting Optional K659-1 Wire Reel Changing Wire Feed Overload ProtectionMaking a Weld Explanation of Prompting Error Messages Maintenance Routine MaintenanceWire Reel Mounting 50 22.7kg and 60lb 27.2kg Coils Avoiding Wire Feeding ProblemsTroubleshooting Guide Problems Communications in control cableProblems For continuity Refer to Wiring Wiring & connectionsWhen trigger is closed and no Gun connector Trigger sockets on gun connectorProblems Cold Feed key does not turn Defective keypad or Display PC Dual Procedure is not Gun has not been selected at With the remote switch open. If aFor replacing PC boards Problems with serial Troubleshooting information. SeeHXX Procedure for Replacing PC Boards Electric Shock can kill Switch RequirementsInside Input I NControl BOX Dimension Print Wire Feed Unit Dimension Print How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung