Crater Fill - Provides crater feed speed adjustment (in 4-step trigger mode) independent of weld, cold feed, or run-in speeds.

Solid-State Overload Protection - No circuit breaker to reset. Front panel display indicates time remaining before automatic reset.

Gas Solenoid Valve - Complete with inlet fittings for easy installation of gas is standard on Synergic 7F models. Also available as an option (K659-1) a Gas Guard regulator for flow surge suppression.

English/Metric Speed Display - Provides front panel selection of speed display in units of IPM or M/M.

4-Roll Drive - Both models employ 4-Roll Drive, with 2 driven rolls, providing optimal feeding force for problem feeding situations, with low wire deformation for improved feeding of soft wires.

Control Features:

Microcomputer Based Control - Provides precise setting and display of all parameters and precision timing functions. Optimizes wire drive control for crisp acceleration and smooth response with precise repeatability. Allows synergic control of various welding processes by communicating information over a serial link to the compatible power source.

Display and Indicator Lights - Wide temperature range, long life, 3-1/2 digit 7-segment LED display with .56” (14.2mm) character height permits easy viewing even from long gun cable distances . Individual red indicator lights are high intensity LED’s for viewing at almost any angle.

Encoder Controls - Rotating encoders provide continuous knob control for setting both Wire Feed Speed and Volts/Trim procedures.

Keypad - Consists of 7 membrane keys with tactile- feel embossed domes. All keys are generously spaced to provide easy selection, even if wearing welding gloves.

2-Step or 4-Step Trigger Modes - Unit operates only when trigger is pressed in 2-Step mode (normal) operation. 4-Step Trigger Mode eliminates the need to hold the gun trigger closed while welding.

Both models have user selectable 4-step with crater fill, or as shipped, 4-step with current interlock.

Gas Preflow and Postflow Timers - Allows setting of shielding gas preflow time (0-2.5 seconds) before welding arc starts, and gas postflow time (0-9.9 seconds), after welding arc stops.

Crater Fill - Allows setting of crater fill WFS (when 4- step with crater fill trigger mode is selected), independent of weld, cold feed, and run-in speeds.

Spot Mode - Allows a single timed weld cycle each time the gun trigger is held closed. Duration (0.2-9.9 seconds) is set by the Spot ON timer.

Digital “Memory” Voltmeter - Displays arc voltage from 0 to 80V DC, when welding gun trigger is activated, with automatic polarity indication for positive or negative electrode. The last welding voltage monitored at end of weld is displayed for 5 seconds after weld has stopped. This allows checking actual voltage after weld has stopped.

Power-down Save - All settings, including mode, Run-in speed, cold feed speed, crater speed, weld speed, timers, English-Metric units and acceleration are automatically saved when power is removed. This feature does not require batteries and when power is restored it will automatically return all settings to the state they were in when power was removed . However, the power source may overwrite any or all of these parameters after Power - Up Recall is complete.

8

Image 8
Contents Synergic 7F and Synergic 7FH ARC Welding can be hazardous Apr. ‘93Cylinder may explode if damaged Mar. ‘93Précautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Please Examine Carton and Equipment For Damage Immediately Standard Features Wire Feed FeaturesGeneral Description Recommended Processes and EquipmentControl Features Causes mode lights to sequence Y P a D a N D D I S P L a Y DescriptionKeypad Seven key, membrane type with snap tactile feel Top to bottom starting fromOptional Features Drive Roll and Guide Tube KitsMiscellaneous Options Model Specifications for Synergic 7F Synergic 7FHType K678-1 K679-1 K679-2 Wire Speed Range Installation Safety PrecautionsProcedure to Install Drive Roll and Guide Tubes Wire Feed Drive Roll and Guide Tube KitsSteel Wire Sizes Roll Aluminum Wire SizesGun and Cable Assemblies with Standard L. E. Connections Gun Cable ConnectionGmaw Guns Innershield GunsGmaw Shielding Gas Gun Cable Connections Wire Feeder to GunSynergic 7F Water Connections for Water-Cooled Guns Electrical Installation Work CableCurrent 60% Duty Cycle Up to 100 ft Length 30mInstallation section for instructions Optional Features InstallationK648 or K649 Input Cable Assembly See Electrical Power-Down Save Operation Keys Mode SelectionOperating Instructions Current indicated positionDisplay Control Keys Run-In Selection Acceleration SelectionSelection of English or Metric Speed Display Units To Mount 10 to 44 lb 4.5-20kg Spool 12/300mm Diameter Step Trigger Mode SelectionFeeding Electrode and Brake Adjustment To Mount a 50-60lb 22.7-27.2kg Coil Feeding ElectrodeGas Guard Regulator Setting Optional K659-1 Wire Loading of 13-14lb 6kg Innershield CoilsIdle Roll Pressure Setting Making a Weld Wire Reel ChangingWire Feed Overload Protection Explanation of Prompting Error Messages Maintenance Routine MaintenanceWire Reel Mounting 50 22.7kg and 60lb 27.2kg Coils Avoiding Wire Feeding ProblemsTroubleshooting Guide Problems Communications in control cableProblems For continuity Refer to Wiring Wiring & connectionsWhen trigger is closed and no Gun connector Trigger sockets on gun connectorProblems Cold Feed key does not turn Defective keypad or Display PC Dual Procedure is not Gun has not been selected at With the remote switch open. If aFor replacing PC boards Problems with serial Troubleshooting information. SeeHXX Procedure for Replacing PC Boards Electric Shock can kill Switch RequirementsInside Input I NControl BOX Dimension Print Wire Feed Unit Dimension Print How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung