Lincoln Electric 8 manual Pre-Operation Service, Welding Output Cables, Awg

Page 11

A-4

INSTALLATION

A-4

 

 

 

Some of the factors to be considered are as follows:

1.Design capacity of trailer vs. weight of Lincoln equipment and likely additional attachments.

2.Proper support of, and attachment to, the base of the welding equipment so there will be no undue stress to the framework.

Pre-Operation Service

CAUTION

READ the engine operating and maintenance instruc- tions supplied with this machine.

WARNING

GASOLINE fuel can cause fire or explosion.-

• Stop engine while fueling.

Do not smoke when fueling.

Do not overfill tank.

Keep sparks and flame away from tank.

Wipe up spilled fuel and allow fumes to clear

before starting engine.

------------------------------------------------------------------------

Battery Connections

This welder is shipped with the negative battery cable disconnected. Make sure that the Engine Switch is in the “STOP” position and attach the disconnected cable securely to the negative battery terminal before attempting to operate the machine. If the battery is discharged and does not have enough power to start the engine, see the battery charging instructions in the Battery section.

Welding Output Cables

With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary. Loose connections will result in overheating of the output studs.

When welding at a considerable distance from the welder, be sure you use ample size welding cables. Listed below are copper cable sizes recommended for the rated current and duty cycle. Lengths stipulated are the distance from the welder to work and back to the welder again. Cable sizes are increased for greater lengths primarily for the purpose of minimizing cable voltage drop.

TOTAL COMBINED LENGTH OF ELECTRODE AND WORK CABLES

Oil

The Ranger 8 is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Make certain that the oil filler cap is tightened securely. Refer to the engine Owner’s Manual for specific oil recommenda- tions.

LUBRICATION SYSTEM CAPACITY

(INCLUDING FILTER)

Onan P218 - 1.8 Quarts (1.7 Liters)

Kohler CH20S - 2.0 Quarts (1.9 Liters)

Honda GX620-1.9 Quarts (1.6 Liters)

Fuel

Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling.

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

200-250 Ft.

225Amps

40% Duty Cycle

3AWG

3AWG

2AWG

1AWG

1/0 AWG

225Amps

100% Duty Cycle

1AWG

1AWG

1AWG

1AWG

1/0 AWG

RANGER 8

Image 11
Contents Ranger Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Ranger InstallationHeight Width Depth Weight K2160-1 CSA Meets Canadian STDOutput Amps DC Stick / TIG CC Output Output Range SpecificationsDC Wire Feed CV Output CV Output Range 20 B 100 150 200 250Machine Grounding Installation InstructionsSafety Precautions Spark ArresterAWG Pre-Operation ServiceWelding Output Cables Location / Ventilation Connection of Lincoln Electric Wire FeedersAngle of Operation High Altitude OperationConnection of K930- TIG Module to the Ranger Additional Safety PrecautionsAuxiliary Power InstructionsMotor Starting Duplex ReceptaclesNot USE These Devices With a Ranger Electrical Device USE with the RangerType Common Electrical Devices Possible Concerns These Devices Without Additional Resistive Type LoadsStandby Power Connections Auxilliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 8 to Premises Wiring General Description Design FeaturesOther Features OperationRanger 8 Approximate Fuel Consumption Engine ON-OFF SwitchEngine Start Push-Button Switch Onan P216 Kohler Honda 16 H.P. Performer 20 H.P. CommandStopping the Engine Starting/Shutdown InstructionsBreak-in Period TIG Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process Stick Constant Current WeldingStick Auto Summary of Welding ProcessesK1745-1 Single GAS Cylinder Holder AccessoriesTIG Wire FeedRecommended Equipment StickCH20S MaintenanceSafety Precautions Onan P216 Kohler CH20S Honda GX620 Overspeed is HazardousHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting K1418-1 Code 10373 & 10535 Ranger 8 Onan Wiring Diagram DiagramsALL Case Front Components Shown Viewed from Rear K1419-1 Code 10375 & 10537 Ranger 8 Kohler Wiring Diagram ALL Case Front Components Shown Viewed from Rear K2160-1 Code 10886 Ranger 8 Honda CSA Wiring Diagram Connection of Ranger 8 to LN-7 & K240 Contactor KIT M17215-2 30-98E M17215-3 30-98E Ranger Basic Course How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung