OPERATION

B-3

 

 

 

Starting/Shutdown Instructions

Starting the Engine

WARNING

• Do not touch electrically live parts of electrode with skin or wet clothing.

Keep flammable material away.

Insulate yourself from work and

ground. Wear eye, ear, and body protection.

• Keep your head out of the fumes.

• Use ventilation or exhaust to remove fumes from breathing zone.

Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner’s Manual.

Remove all loads connected to the AC power recepta- cles. To start the engine, set the “Idler Control” switch

in the Automatic ( /) position. Use the choke control as follows:

Onan Engine - If the engine is cold, pull the choke control out. Do not use the choke if the engine is warm or hot.

Kohler Engine - Always pull the choke control out when starting the engine; cold, warm or hot. Place the “Engine” switch in the “ON” position.

Honda Engine - Always pull the choke control out when starting the engine; cold. Place the “Engine” switch in the “ON” position.

Push the “START” button and crank the engine until it starts. Release the button as soon as the engine starts. Do not push the “START” button while the engine is running because this will cause damage to the ring gear and/or starter motor. After the engine has started, slowly return the choke control to the full “in” position (choke open).

After running at high engine speed for 10-14 seconds, the engine will go to low idle.

Allow the engine to warm up by letting it run at low idle for a few minutes.

Stopping the Engine

Remove all welding and auxiliary power loads and allow engine to run at low idle speed for a few minutes to cool the engine.

Stop the engine by placing the “Engine” switch in the “OFF” position.

A fuel shut off valve is not required on the Ranger 8 because the fuel tank is mounted below the engine.

Break-in Period

It is normal for any engine to use a greater amount of oil until the break-in is accomplished. Check the oil level twice a day during the break-in period (approxi- mately 50 running hours)).

IMPORTANT: IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE UNIT SHOULD BE SUBJECTED TO MODERATE LOADS, WITHIN THE RATING OF THE MACHINE. AVOID LONG IDLE RUNNING PERIODS. REMOVE LOADS AND ALLOW ENGINE TO COOL BEFORE SHUTDOWN.

The engine manufacturer’s recommendation for the running time until the first oil change is as follows:

Kohler

Onan

Honda

CH20S

P216

GX620

 

 

 

5 HRS

25 HRS

First Month

 

 

or 20 HRS

 

 

 

The oil filter is to be changed at the second oil change. Refer to the Engine Owner’s Manual for more information.

RANGER 8

Image 20
Contents Safety Depends on You RangerSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Installation Height Width Depth WeightK2160-1 CSA Meets Canadian STD RangerSpecifications DC Wire Feed CV Output CV Output Range20 B 100 150 200 250 Output Amps DC Stick / TIG CC Output Output RangeInstallation Instructions Safety PrecautionsSpark Arrester Machine GroundingAWG Pre-Operation ServiceWelding Output Cables Connection of Lincoln Electric Wire Feeders Angle of OperationHigh Altitude Operation Location / VentilationAdditional Safety Precautions Auxiliary PowerInstructions Connection of K930- TIG Module to the RangerDuplex Receptacles Motor StartingElectrical Device USE with the Ranger Type Common Electrical Devices Possible ConcernsThese Devices Without Additional Resistive Type Loads Not USE These Devices With a RangerStandby Power Connections Auxilliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 8 to Premises Wiring Design Features Other FeaturesOperation General DescriptionEngine ON-OFF Switch Engine Start Push-Button SwitchOnan P216 Kohler Honda 16 H.P. Performer 20 H.P. Command Ranger 8 Approximate Fuel ConsumptionStopping the Engine Starting/Shutdown InstructionsBreak-in Period Wire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingSummary of Welding Processes Stick AutoAccessories K1745-1 Single GAS Cylinder HolderWire Feed Recommended EquipmentStick TIGCH20S MaintenanceSafety Precautions Overspeed is Hazardous Onan P216 Kohler CH20S Honda GX620Troubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Diagrams K1418-1 Code 10373 & 10535 Ranger 8 Onan Wiring DiagramALL Case Front Components Shown Viewed from Rear K1419-1 Code 10375 & 10537 Ranger 8 Kohler Wiring Diagram ALL Case Front Components Shown Viewed from Rear K2160-1 Code 10886 Ranger 8 Honda CSA Wiring Diagram Connection of Ranger 8 to LN-7 & K240 Contactor KIT M17215-2 30-98E M17215-3 30-98E Ranger How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? Basic CoursePrecaucion Warnung