Lincoln Electric manual Connection of Ranger 8 to LN-7 & K240 Contactor KIT

Page 35

F-6

DIAGRAMS

F-6

 

 

 

 

RANGER 8 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

 

WARNING

Do not operate with panels open.

Disconnect NEGATIVE (-) BATTERY LEAD

before servicing.

Do not touch electrically live parts.

Keep guards in place.

Keep away from moving parts.

Only qualified personnel should install,use or service this equipment.

6 PIN

AMPHENOL

OPTIONAL K444-1

TO WORK

ELECTRODE

REMOTE CONTROL

LN-25

WIRE FEEDER

WORK CLIP LEAD

TO WORK

TO WORK

ELECTRODE CABLE

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO THE WIRE FEED (CV) POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.

CRM 21883

M17486

CONNECTION OF RANGER 8 TO LN-7 & K240 CONTACTOR KIT

CONNECTION OF LN - 7 & K240 CONTACTOR KIT WITH 115 VOLT AC AUXILIARY POWER AND CV OUTPUT

CONTROL CABLE

N . D .

CONNECT THE CONTROL CABLE

GROUND LEAD TO THE FRAME

TERMINAL MARKED NEAR

THE TERMINAL STRIP OR TO

AN UNPAINTED FRAME SCREW .

N . F . & N . G .

N . J .

21

N . C .

N . B .

POWER

SOURCE

77 76 75

WORK ELECTRODE

G N D . 3 2 2 4 3 1

 

TO LN - 7

K240 CONTACTOR KIT

115V (50/60HZ . )

(NOTE : 600 AMP CAPACITY)

3 2

2

4

31

 

 

 

 

AUTO . POWER

EQUIP . SOURCE

ELECTRODE CABLE TO LN - 7

DER STANDARD OUTPUT TERMINALS

WARNING: Turn the power off when making connections.

N.A. Use power source polarity switch to set for desired elec- trode polarity. Position the output selector switch on the power source to the CV position.

N.B. 3 conductor #16 power cord physically suitable for the installation and plug rated at 115 volts 15 amperes AC.

N.C. Plug into 115 volt AC receptacle on welder control panel or other 115 volt AC supply rated at a minimum of 500 volt- amperes.

N.D. Leads #21 and GND do not appear on LN-7’s with codes below 7026.

N.E. Welding cables must be of proper capacity for the current and duty cycle of immediate and future applications.

N.F. If LN-7 is equipped with a meter kit, extend lead #21 using #14 or larger insulated wire physically suitable for the

S17742

TO WORK 10-2-92

installation. An S16586-”length” remote voltage sensing work lead may be ordered for this purpose. Connect it directly to the work piece independent of the welding work cable. For convenience, this extended #21 lead should be taped to the welding work lead.

N.G. Tape up bolted connection where lead #21 is extended.

N.H. Idler switch on power source must be in high idle position.

N.J. If an optional remote output control is used, connect it to this terminal strip or 6 pin Amphenol receptacle. NOTE: Terminal strip or 6 pin Amphenol receptacle not available on all power sources.

CAUTION: Any speed up of the engine RPM by changing the governor setting or over-riding the throttle linkage will cause an increase in the AC auxiliary voltage. If this volt- age goes above 140 volts, the LN-7 control circuit will be damaged. The engine governor setting is pre-set at the fac- tory - do not adjust above RPM specifications listed in engine welder operating manual.

RANGER 8

Image 35
Contents Ranger Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Ranger InstallationHeight Width Depth Weight K2160-1 CSA Meets Canadian STDOutput Amps DC Stick / TIG CC Output Output Range SpecificationsDC Wire Feed CV Output CV Output Range 20 B 100 150 200 250Machine Grounding Installation InstructionsSafety Precautions Spark ArresterAWG Pre-Operation ServiceWelding Output Cables Location / Ventilation Connection of Lincoln Electric Wire FeedersAngle of Operation High Altitude OperationConnection of K930- TIG Module to the Ranger Additional Safety PrecautionsAuxiliary Power InstructionsMotor Starting Duplex ReceptaclesNot USE These Devices With a Ranger Electrical Device USE with the RangerType Common Electrical Devices Possible Concerns These Devices Without Additional Resistive Type LoadsStandby Power Connections Auxilliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 8 to Premises Wiring General Description Design FeaturesOther Features OperationRanger 8 Approximate Fuel Consumption Engine ON-OFF SwitchEngine Start Push-Button Switch Onan P216 Kohler Honda 16 H.P. Performer 20 H.P. CommandStopping the Engine Starting/Shutdown InstructionsBreak-in Period TIG Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process Stick Constant Current WeldingStick Auto Summary of Welding ProcessesK1745-1 Single GAS Cylinder Holder AccessoriesTIG Wire FeedRecommended Equipment StickCH20S MaintenanceSafety Precautions Onan P216 Kohler CH20S Honda GX620 Overspeed is HazardousHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting K1418-1 Code 10373 & 10535 Ranger 8 Onan Wiring Diagram DiagramsALL Case Front Components Shown Viewed from Rear K1419-1 Code 10375 & 10537 Ranger 8 Kohler Wiring Diagram ALL Case Front Components Shown Viewed from Rear K2160-1 Code 10886 Ranger 8 Honda CSA Wiring Diagram Connection of Ranger 8 to LN-7 & K240 Contactor KIT M17215-2 30-98E M17215-3 30-98E Ranger Basic Course How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung