Lincoln Electric 305D manual Electrical Connections

Page 12

A-4

INSTALLATION

A-4

 

 

 

ENGINE COOLING SYSTEM

WARNING

Air to cool the engine is drawn in the base sides and exhaust through radiator & case back. It is important that the intake and exhaust air is not restricted. Allow a minimum clearance of 2 feet (0.6m) from the case back and 16in.(406mm) from either side of the base to a vertical surface.

--------------------------------------------------------------------------------

bATTERY CONNECTION

CAUTION

Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.

--------------------------------------------------------------------------------

The RANGER® 305D is shipped with the negative battery cable disconnected. Make certain that the RUN-STOP switch is in the STOP position. Remove the two screws from the rear battery tray using a screwdriver or a 3/8" socket. Attach the negative bat- tery cable to the negative battery terminal and tighten using a 1/2" socket or wrench.

NOTE: This machine is furnished with a wet charged battery; if unused for several months, the battery may require a booster charge. Be careful to charge the bat- tery with the correct polarity.

MUFFLER OUTLET PIPE

Using the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust in the desired direction. Tighten using a 9/16" socket or wrench.

SPARK ARRESTER

Some federal, state or local laws may require that gasoline or diesel engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, a suitable spark arrester, such as the K1898-1 must be installed and properly main- tained.

WARNING

An incorrect spark arrestor may lead to damage to the engine or adversely affect performance.

--------------------------------------------------------------------------------

REMOTE CONTROL

The RANGER® 305D is equipped with a 6-pin and a 14-pin connector. The 6-pin connector is for connect- ing the K857 or K857-1 Remote Control or for TIG welding, the K870 foot Amptrol or the K936-3 hand Amptrol. When in the CC-STICK, DOWNHILL PIPE, or CV-WIRE modes and when a remote control is connected to the 6-pin Connector, the auto-sensing circuit automatically switches the OUTPUT control from control at the welder to remote control.

When in TOUCH START TIG mode and when a Amptrol is connected to the 6-Pin Connector, the OUTPUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.

The 14-pin connector is used to directly connect a wire feeder control cable. In the CV-WIRE mode, when the control cable is connected to the 14-pin con- nector, the auto-sensing circuit automatically makes the Output Control inactive and the wire feeder volt- age control active

WARNING

NOTE: When a wire feeder with a built in welding voltage control is connected to the 14-pin connec- tor, do not connect anything to the 6-pin connec- tor.

--------------------------------------------------------------------------------

ELECTRICAL CONNECTIONS

MACHINE GROUNDING

Because this portable engine driven welder creates its own power, it is not necessary to connect its frame to an earth ground, unless the machine is connected to premises wiring (home, shop, etc.)

To prevent dangerous electric shock, other equipment to which this engine driven welder supplies power must:

WARNING

be grounded to the frame of the welder using a grounded type plug.

be double insulated.

Do not ground the machine to a pipe that carries

explosive or combustible material.

--------------------------------------------------------------------------------

RANGER® 305D

Image 12
Contents Safety Depends on You Ranger 305DSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiIvSAFETY Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Vii Section DSection E Section FTechnical Specifications Ranger 305D K1727-3 Safety Precautions Cold weather startingLocation and Ventilation PRE-OPERATION Engine Service TowingVehicle Mounting OILElectrical Connections CAbLE Installation Welding TerminalsWelding Output CAbLES Total COMbINED Length Electrode and Work CAbLESElectrical Device USE with the Ranger 305D Type Common Electrical Devices Possible ConcernsAuxiliary Power Receptacles STANDbY Power ConnectionsConnection of Ranger 305D to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of LN-15 to the Ranger 305DAcross The-Arc Model Control Cable ModelTerminals on Connection of Prince XL Spool GUN to the Ranger 305DSafety Precautions For Auxiliary PowerGeneral Description Engine OperationWeld Mode Selector Switch Welding Controls Figure b.1Wire Feeder Voltmeter Switch Engine Controls Figure b.2Glow Plug Push bUTTON Start Push bUTTONStarting the Engine Stopping the EngineWelder Operation TAbLE b.1Constant Current CC-STICK Welding TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Downhill Pipe WeldingWire WELDING-CV ARC GougingAuxiliary Power Ranger 305D Extension Cord Length RecommendationsField Installed Options / Accessories T12153-9 50 AMP, 120/240 V Power PlugRoutine Maintenance Engine Maintenance Components KUbOTA D722 Diesel EngineKUbOTA D722 Diesel Engine AIR Cleaner Engine Oil ChangeOil Filter Change Engine Oil Refill capacitiesCheck Connectors for Tight Fit Remove the FilterInspect the New Filter for Damage Insert the New Radial Seal Filter ProperlyCooling System Tightening the FAN bELTBLEEDING the Fuel System Engine Adjustment BATTERY MaintenanceServicing Optional Spark ArrestorWelder / Generator Maintenance Gfci Receptacle Testing and RESET- Ting ProcedureTROUbLESHOOTING HOW to USE TROUbLESHOOTING GuidePRObLEMS SymptomsPOSSIbLE Cause Recommended Course of ActionWelding without a control cable Functioning properly / linkage Faulty control cable. Repair or Field Service Facility Your local Lincoln AuthorizedDiagrams Diagrams Diagrams Diagrams Engine Welders /LN-8 Connection Diagram S24787-6Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print Ranger 305D Ranger 305D Precaucion Guards off