CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

Connection of LN-7 or LN-8 to the RANGER® 305D

Shut the welder off.

Connect the LN-7 or LN-8 per instructions on the appropriate connection diagram in Section F.

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode being used.

Set the "MODE" switch to the "CV WIRE " position.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "WELD TERMINALS" switch to the "REMOTELY CONTROLLED" position.

Set the "IDLE" switch to the "HIGH" position.

Connection of LN-15 to the Ranger® 305D

These connections instructions apply to both the LN-

15Across The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Across The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Set the "WELD TERMINALS" switch to "WELD TER-

MINALS ON"

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the "WELD TERMINALS" switch to "REMOTELY CONTROLLED".

Set the MODE switch to the "CV-WIRE " position.

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "AUTO" position

RANGER® 305D

Image 17
Contents Ranger 305D Safety Depends on YouSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté IvSAFETYOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents Section D ViiSection E Section FTechnical Specifications Ranger 305D K1727-3 Location and Ventilation Safety PrecautionsCold weather starting Towing PRE-OPERATION Engine ServiceVehicle Mounting OILElectrical Connections Welding Terminals CAbLE InstallationWelding Output CAbLES Total COMbINED Length Electrode and Work CAbLESType Common Electrical Devices Possible Concerns Electrical Device USE with the Ranger 305DSTANDbY Power Connections Auxiliary Power ReceptaclesConnection of Ranger 305D to Premises Wiring Connection of LN-15 to the Ranger 305D Connection of Lincoln Electric Wire FeedersAcross The-Arc Model Control Cable ModelConnection of Prince XL Spool GUN to the Ranger 305D Terminals onFor Auxiliary Power Safety PrecautionsGeneral Description Engine OperationWelding Controls Figure b.1 Weld Mode Selector SwitchEngine Controls Figure b.2 Wire Feeder Voltmeter SwitchGlow Plug Push bUTTON Start Push bUTTONStopping the Engine Starting the EngineWelder Operation TAbLE b.1TIG Welding Constant Current CC-STICK WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Downhill Pipe WeldingARC Gouging Wire WELDING-CVRanger 305D Extension Cord Length Recommendations Auxiliary PowerT12153-9 50 AMP, 120/240 V Power Plug Field Installed Options / AccessoriesKUbOTA D722 Diesel Engine Routine MaintenanceEngine Maintenance Components KUbOTA D722 Diesel Engine Engine Oil Change AIR CleanerOil Filter Change Engine Oil Refill capacitiesRemove the Filter Check Connectors for Tight FitInspect the New Filter for Damage Insert the New Radial Seal Filter ProperlyBLEEDING the Fuel System Cooling SystemTightening the FAN bELT BATTERY Maintenance Engine AdjustmentServicing Optional Spark ArrestorGfci Receptacle Testing and RESET- Ting Procedure Welder / Generator MaintenanceHOW to USE TROUbLESHOOTING Guide TROUbLESHOOTINGSymptoms PRObLEMSPOSSIbLE Cause Recommended Course of ActionWelding without a control cable Functioning properly / linkage Faulty control cable. Repair or Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams S24787-6 Engine Welders /LN-8 Connection DiagramDiagrams Diagrams Diagrams Diagrams Diagrams Dimension Print Ranger 305D Ranger 305D Precaucion Guards off