STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" sec- tion on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to "OFF" and unplug unit.

3.Turn the regulator counterclock- wise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately

20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Risk of Bursting. Water will con-

dense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped)

Store the air compressor in a clean and dry location.

A14411

20- ENG

Image 20
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions What Could Happen Always remain in attendance withAttachments & Accessories Safety equipment must be properly Electricity. Like any other electricallyRepairs attempted by unqualified Personnel can result in serious injuryResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherAccessories AccessoriesGlossary Duty CycleAssembly Contents of CartonTools Required for Assembly Assemble WheelsIllustration InstallationLocation of the Air Compressor Extension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation Tank Pressure Gauge The tankHow to Stop Before StartingHow to Start Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesMotor Air FilterService and Adjustments To Replace or Clean Check ValveOutlet Tube Nut Pressure Relief TubeTo Replace Regulator Regulator Quick ConnectNipple Regulator ArrowStorage Troubleshooting Pressure reading Check wiring connection Table DES Matières Pleine Garantie D’UN ANConsignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionAvertissement Risque de projection dobjets Avertissement Risque déclatementRisque Prévention Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque de chute Prévention Avertissement Risque de brûluresAvertissement Risque relié aux pièces mobiles Risque Avertissement Risque dune utilisation dangereuseAccessoires Cycle DE ServiceAccessoires LexiqueAssemblage Contenu de lemballage en carton Assemblage desOutils requis pour lassemblage DéballageLillustration Terre inappropriée peut entraîner des chocs électriquesRisque dune utilisation RallongesProtection contre la surtension et protection du circuit Description du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Utilisation de lappareil Arrêt de lappareilAvant le démarrage Soupape de décharge de pression LaAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirRisque de brûlures Filtre à air Inspection et remplacementMoteur Remplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Rangement Dépannage SerrerRisque déclatement.Ne Peut éclater ou exploserUne légère chute de pression est Pas Surcharges déclenché 54- FR 55- FR A14411 Canada MY-HOMESears Parts and Repair Center