PROBLEM | CAUSE | CORRECTION |
Regulator will | Damaged regulator | Replace |
not shut off air |
|
|
outlet. |
|
|
Motor will not | Motor overload protection | Let motor cool off and over- |
run. | switch has tripped | load switch will automatically |
|
| reset. |
| Tank pressure exceeds pres- | Motor will start automatically |
| sure switch | when tank pressure drops |
| sure. | below |
|
| pressure switch. |
| Extension cord is wrong | Check for proper gauge wire |
| length or gauge. | and cord length. |
| Check valve stuck open. | Remove and clean, or |
|
| replace. |
| Loose electrical connections. | Check wiring connection |
|
| inside pressure switch and |
|
| terminal box area. |
| Possible defective motor or | Have checked by a Trained |
| starting capacitor. | Service Technician. |
| Paint spray on internal motor | Have checked by a Trained |
| parts. | Service Technician. Do not |
|
| operate the compressor in |
|
| the paint spray area. See |
|
| flammable vapor warning. |
| Pressure release valve on | Bleed the line by pushing the |
| pressure switch has not | lever on the pressure switch |
| unloaded head pressure. | to the "off" position; if the |
|
| valve does not open, replace |
|
| switch. |
| Fuse blown, circuit breaker | 1. Check fuse box for blown |
| tripped. | fuse and replace as neces- |
|
| sary. Reset circuit breaker. |
|
| Do not use a fuse or circuit |
|
| breaker with higher rating |
|
| than that specified for your |
|
| particular branch circuit. |
|
| 2. Check for proper fuse. You |
|
| should use a time delay |
|
| fuse. |
|
| 3. Check for low voltage |
|
| conditions and/or proper |
|
| extension cord. |
|
| 4. Disconnect the other |
|
| electrical appliances from |
|
| circuit or operate the com- |
|
| pressor on its own branch |
|
| circuit. |
|
|
|
23- ENG | A14411 |