Craftsman 919.167461 owner manual Service and Adjustments, To Replace or Clean Check Valve

Page 17

SERVICE AND ADJUSTMENTS

All maintenance and repair opera- tions not listed must be performed by Trained Service Technician.

Risk of Unsafe

Operation. Unit

cycles automatically when power is on. When servicing, you may be exposed to voltage sources, com- pressed air, or moving parts.

Before servicing unit unplug or dis- connect electrical supply to the air compressor, bleed tank of pres- sure, and allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Set the On/Auto/Off lever to “OFF” and unplug unit.

3.Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve.

Pressure

 

Relief Tube

Nut

Outlet

Tube

Nut Check

Valve

4.Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve.

5.Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the ori- entation for reassembly.

6.Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position, if not the check valve needs to be cleaned or replaced.

Screwdriver

In open position nothing is visible.

In closed position disc is visible.

7.Clean or replace the check valve. A solvent, such as paint or var- nish remover can be used to clean the check valve.

8.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

9.Replace the pressure release tube. Tighten nuts.

10.Replace the outlet tube and tighten nuts.

11.Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.

17- ENG

D28071

Image 17
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Model No 919-167461Product when it is operating What Could Happen How To Prevent ItSpray area. An additional length of hose Explosion May be requiredBefore attempting maintenance, attaching Soft tissue damage to exposed skinTools or accessories Tank is designed to withstand specificTive covers removed or damaged Erly it may cause electric shockRepairs attempted by unqualified per Accordance with national and local electriResult in serious burns Or attempt maintenance until unit hasHot for several minutes after operation Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Accessories AccessoriesGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsOperation On/Auto Off SwitchKnow Your Air Compressor Description of OperationBefore Starting How to StopAir Compressor Pump Break-in instructions Risk of Unsafe Operation. SeriousBefore Each Start-Up How to StartTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankMotor Air Compressor Pump Intake and Exhaust ValvesTo Replace or Clean Check Valve Service and AdjustmentsPressure Relief Tube Nut Outlet Nut Check Valve Screwdriver Open position nothing is visibleStorage Problem Cause Correction TroubleshootingPressure reading Minal box area Garantía Total DE UN AÑO DEL Compresor DE Aire ContenidoGarantía Modelo Nº Definiciones DE Normas DE SeguridadAdas Lesiones serias Daños en la propiedadaCómo prevenirlo Instrucciones Importantes DE SeguridadGuarde Estas Instrucciones Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónD28071 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Accesorios GlosarioCiclo DE Servicio Presión mínima de corte Cuando elInstalación EnsambladoCómo Preparar LA Unidad DesempaqueRiesgo de Operación Cables de extensión eléctricaProtección del voltaje y del circuito Conozca su compresor de aire OperaciónDescripción de operaciones InterruptorAntes de poner en marcha Cómo utilizar su unidadCómo detenerla Procedimiento para el asentamientoCómo poner en marcha Antes de cada puesta en marchaResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguri- dad Cómo drenar el tanqueFiltro de Aire Inspección y reempla- zo Tubo aliviador Servicio Y AjustesPara reemplazar o limpiar la válvu La de retención Almacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasRiesgo Alguna porque se debilitaráOperación. Nota Ajuste la presión Compruebe la conexión de cablea D28071 46- SP Repair Protection Agreements Product replacement if your covered product cant be fixedSears Parts and Repair Center MY-HOMECanada SU-HOGARSM