Friedrich 2003 service manual Troubleshooting Chart Cooling

Page 44

PROBLEM

POSSIBLE CAUSE

TO CORRECT

 

 

 

 

 

 

Compressor will not

Outdoor thermostat.

Refer to the heating data on applicable models for

turn off and operate on

(Applicable models.)

the preselected temperature the compressor shuts

heating element only

 

off and the electric element is energized.

during low outside

 

 

ambients.

 

 

 

 

 

Troubleshooting Chart — Cooling

REFRIGERANT SYSTEM

DIAGNOSIS COOLING

 

 

Low Suction Pressure

 

High Suction Pressure

 

Low Head Pressure

 

High Head Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Load Conditions

 

High Load Conditions

 

Low Load Conditions

 

High Load Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Air Flow Across

 

High Air Flow Across

 

Refrigerant System

 

Low Air Flow Across

 

 

Indoor Coil

 

Indoor Coil

 

Restriction

 

Outdoor Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant System

 

Reversing Valve not

 

 

Reversing Valve not

 

Overcharged

 

 

Restriction

 

Fully Seated

 

 

Fully Seated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Undercharged

 

Overcharged

 

Undercharged

 

Noncondensables (air)

 

 

 

 

 

 

 

 

 

in

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture in System

 

Defective Compressor

 

Defective Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

Image 44
Contents 2003 Table of Contents 00001 1st Digit FunctionRAC Serial Number Identification Guide Page Data Evaporator AIR Operating Electrical Breaker Pressures Ratings Refrig Fuse Performance Evaporator AIR Operating Electrical Breaker Data SS10J10AR-A TEMP. DEG. F Pressures Ratings Heating SC06H10EAmps WY09A33F-A WY12A33F-A HeatingBtuh Refrigeration System Sequence of Operation Wire Size Fuse/CircuitBreaker GroundingChecking Compressor Efficiency Thermal Overload ExternalWinding Test Terminal Overload Test Terminal Overload InternalChecking the Internal Overload FAN MotorResistor EQ Model Only See Figure System Control Panel KQ Models Only- See FigureSystem Control Panel System Control Panel YQ Model Only System Control Switch WE & WY Models See Figure System Control Switch TestSystem Control Switch KS, SS, KM, SM, SL Models See Figure System Control Panel See FigureSystem Control Switch Heat Pump & Electric Heat Models See FigureTo SET Mode of Operation To Adjust TemperatureTo Adjust FAN Speed Smart Center Electronic Control CenterTo SET the Timer Testing the Electronic ControlTesting the Electronic Control Error Code Listings To SET Hour ClockTest Thermostat SQ & KQ Models See FigureThermostat YQ Model Only See Figure Thermostat Models ES, YS, EM, YM, EL, YL See FigureThermostat Bulb Location Thermostat AdjustmentDefrost Thermostat Heat Pump Models Only Capacitor Test Defrost Bulb Location Heat Pump Models OnlyCAPACITOR, RUN See Figure Check Valve Operation Heat Pumps Reversing Valve See FigureTo Test Testing Reversing ValveSolenoid Coil Heat Pump Models Only See Figure VALVE, Drain PAN See Figure Heating Element See FigureSealed Refrigeration System Repairs Equipment RequiredHermetic Component Replacement Special Procedure in the Case Compressor Motor BurnoutRotary Compressor Special Troubleshooting and Service Equipment Must be CapableUndercharged Refrigerant Systems Method of ChargingOvercharged Refrigerant Systems Restricted Refrigerant System Routine Maintenance Troubleshooting Touch Test Chart To Service Reversing Valves Troubleshooting Cooling Problem To CorrectProblem Possible Cause To Correct Cycles Problem Possible Cause To Correct Troubleshooting Heating Heat pumps Problem Possible Cause To Correct Off and the electric element is energized Troubleshooting Heating Cooling/Electric Models Troubleshooting Chart Cooling System Cools When Heating is Desired YESModels SQ06J10B-B, SQ06J10B-A, SQ08J10C-A, SQ08J10D-A Models KQ08J10B-1, KQ08J10B-A, KQ08J10C-A Schematic Model YQ06J10B-AModel SC06H10D 619-405-06 SL28J30B-A, SL35J30-A, SL35J30-B AlternateConductor Or Brown RED Blue To Capacitor Bracket Wiring Diagram YS12J33-A, YM18J34B-A, YL24J35C-A Model EQ08J11-A, EQ08J11-B IDT Ovld Neutral WE09A33E-B, WE12A33E-A, WE15A33-A WY09A33F-A, WY12A33G-A Testing The Electronic Control XQ Boards & QME Boards Checking Room TemperatureFriedrich AIR Conditioning CO