Friedrich 2003 service manual Conductor Or Brown RED Blue To Capacitor Bracket

Page 55

MODELS

KS10E10-A, KS10J10-B, KS12E10-A, KS12J10B-A, KS15J10-A,

KS12J30B-A, KS18J30-A, KM20J30-A, KM24J30-A

"F"

COMPRESSOR

 

 

C

R

COMPRESSOR TERMINAL

WIRING DIAGRAM

 

 

 

 

 

S

ORIENTATION MAY VARY. REFER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO MARKING ON COMPRESSOR.

 

 

C

 

 

BLUE

 

 

 

RED

S

R

"F"

"F"

RED

 

PURPLE

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

SYSTEM SWITCH

 

 

 

 

 

 

 

 

ALTERNATE

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

BLUE

 

C

BLUE

 

 

 

 

 

 

2

OVERLOAD

 

 

 

 

MS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTECTOR

 

 

 

 

L

M

L1

H

 

 

 

 

 

 

BLUE

 

GREY RED

BROWN

ORANGE

BLUE

 

BLACK

HARNESS,

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

MOLDED

 

 

 

3 2 1

 

 

 

 

 

 

ANTICIPATOR

 

ROCKER SWITCH (GE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESISTOR

 

 

 

 

 

 

BLACK OR WHITE

BLACK

CAPACITOR

1 2

THERMOSTAT

CONDUCTOR

OR BROWN

RED

BLUE

TO CAPACITOR

BRACKET

GREEN

TO CHASSIS

 

c

FAN

HERM

 

WHITE

BROWN

GREEN OR GREEN/YELLOW

TO INNERWALL/ MOTOR MOUNT

ORANGE

BLUE

BLACK

FAN

MOTOR

BLUE

RIBBED CONDUCTORSMOOTH

 

 

SUPPLY CORD

BLUE

GREEN OR GREEN/YELLOW

TO CAPACITOR

BRACKET

OR

 

 

SCHEMATIC

L1

AR

1

IDT

2 1

OVLD

L2

R

L1

C

CCOMPR

 

2

 

2

MS

H

 

1

3

S

HIGH

HERM C

CAP

NO

 

2

M

MS

 

4

R

OVLD

MEDIUM

MTR

 

YES

3

L

5

SYS SW

S

LOW

FAN C

CAP

SWITCH LOGIC

X = CLOSED

 

0 = OPEN

 

 

 

 

 

 

 

 

 

 

 

SWITCH POSITION

 

CIRCUIT

 

 

 

 

 

 

 

 

1

2

3

4

5

OFF

O

O

O

O

O

LOW COOL

X

O

O

O

X

MED COOL

X

O

O

X

O

HI COOL

X

O

X

O

O

FAN ONLY

O

X

O

O

O

 

L E G E N D

AR

- ANTICIPATOR RESISTOR

MS

- MONEY SAVER/ROCKER SWITCH

CAP

- CAPACITOR

COMPR

- COMPRESSOR

MTR

- FAN MOTOR

OVLD

- OVERLOAD PROTECTOR

SYS SW

- SYSTEM SWITCH

IDT

- INDOOR THERMOSTAT

-GROUND LEAD

-COMBINATION TERMINAL

-PLASTIC INSULATOR

PART NO.

REV.

619-405-01

00

55

Image 55
Contents 2003 Table of Contents RAC Serial Number Identification Guide 1st Digit Function00001 Page Data Evaporator AIR Operating Electrical Breaker Pressures Ratings Refrig Fuse Performance Evaporator AIR Operating Electrical Breaker Data SS10J10AR-A TEMP. DEG. F Pressures Ratings SC06H10E HeatingBtuh WY09A33F-A WY12A33F-A HeatingAmps Refrigeration System Sequence of Operation Grounding Wire SizeFuse/Circuit BreakerWinding Test Thermal Overload ExternalChecking Compressor Efficiency FAN Motor Terminal Overload TestTerminal Overload Internal Checking the Internal OverloadResistor System Control Panel System Control Panel KQ Models Only- See FigureEQ Model Only See Figure System Control Panel YQ Model Only System Control Switch Test System Control Switch WE & WY Models See FigureSystem Control Panel See Figure System Control Switch KS, SS, KM, SM, SL Models See FigureHeat Pump & Electric Heat Models See Figure System Control SwitchSmart Center Electronic Control Center To SET Mode of OperationTo Adjust Temperature To Adjust FAN SpeedTo SET Hour Clock To SET the TimerTesting the Electronic Control Testing the Electronic Control Error Code ListingsThermostat Models ES, YS, EM, YM, EL, YL See Figure TestThermostat SQ & KQ Models See Figure Thermostat YQ Model Only See FigureDefrost Thermostat Heat Pump Models Only Thermostat AdjustmentThermostat Bulb Location CAPACITOR, RUN See Figure Defrost Bulb Location Heat Pump Models OnlyCapacitor Test Heat Pumps Reversing Valve See Figure Check Valve OperationSolenoid Coil Heat Pump Models Only See Figure Testing Reversing ValveTo Test Equipment Required VALVE, Drain PAN See FigureHeating Element See Figure Sealed Refrigeration System RepairsEquipment Must be Capable Hermetic Component ReplacementSpecial Procedure in the Case Compressor Motor Burnout Rotary Compressor Special Troubleshooting and ServiceMethod of Charging Undercharged Refrigerant SystemsOvercharged Refrigerant Systems Restricted Refrigerant System Routine Maintenance Troubleshooting Touch Test Chart To Service Reversing Valves Problem To Correct Troubleshooting CoolingProblem Possible Cause To Correct Cycles Problem Possible Cause To Correct Troubleshooting Heating Heat pumps Problem Possible Cause To Correct Off and the electric element is energized Troubleshooting Heating Cooling/Electric Models Troubleshooting Chart Cooling YES System Cools When Heating is DesiredModels SQ06J10B-B, SQ06J10B-A, SQ08J10C-A, SQ08J10D-A Models KQ08J10B-1, KQ08J10B-A, KQ08J10C-A Schematic YQ06J10B-A ModelModel SC06H10D 619-405-06 Alternate SL28J30B-A, SL35J30-A, SL35J30-BConductor Or Brown RED Blue To Capacitor Bracket Wiring Diagram YS12J33-A, YM18J34B-A, YL24J35C-A Model EQ08J11-A, EQ08J11-B IDT Ovld Neutral WE09A33E-B, WE12A33E-A, WE15A33-A WY09A33F-A, WY12A33G-A Checking Room Temperature Testing The Electronic Control XQ Boards & QME BoardsFriedrich AIR Conditioning CO