Campbell Hausfeld HU2000, HM7000 operating instructions Spraying Precautions

Page 2

Portable Air Compressors

General Safety (Cont.)

1.Read instruction manuals for each component carefully, before attempting to assemble, disassemble or operate your particular system.

2.Wear safety glasses and use hearing protection

when operating the pump or unit.

3.Do not stand on or use the pump or unit as a handhold.

4.Do not exceed pressure rating of any component in system.

5.Protect material lines and air lines from damage or puncture. Keep hose and power cable away from sharp objects, chemical spills, oil, solvents, and wet floors.

6.Never point a spray gun at oneself or any other person. Accidental discharge may result in serious injury.

7.Check hoses for weak or worn condition, before each use, making certain all connections are secure; do not use if deficiency is found. Notify an authorized service facility for examination or repair.

Do not run unattended. Leaving

compressor in ON position may allow it to turn on inadvertently. To prevent this and possible damage from power surge, turn to OFF position after each use.

8.Release all pressures within system slowly; dust and debris may be harmful.

Keep

fingers away from a running

compressor; fast moving and hot parts will cause injury and/or burns.

Disconnect power and depressurize

system before servicing air compressor!

9.Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

10.Wiring and fuses should follow electrical codes, current capacity, and be properly grounded.

11.Electric motors must be securely and adequately grounded. See grounding instructions and extension cord information, in this manual.

12.Always disconnect power source before working on or near a motor, or its connected load. If power disconnect point is out-of-sight, lock it in the open position and tag to prevent unexpected application of power.

13.Guard all moving parts; keep visitors away. Never allow children in work area.

14.Use only a properly grounded outlet that will accept a three pronged plug, and wear shoes to prevent shock hazards.

Be

careful when touching exterior of operating motor; it may be hot enough to cause injury.

Compressor parts may be hot even if the unit is stopped.

15.Protect power cable from coming in contact with sharp objects.

16.Clean electrical or electronic equipment with an approved cleaning agent, such as dry, nonflammable cleaning solvent.

Motors,

electrical equipment and controls can cause electrical arcs that

will ignite a flammable gas

or vapor. Never operate or repair the unit near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor.

17. To reduce fire hazard, keep engine/motor exterior free of oil, solvent, or grease.

18.To avoid spontaneous combustion, discard waste rags into approved metal waste cans.

19.NEVER reset safety valve or pressure switch. Keep safety valve free from paint and other accumulations. This provides safety against over pressure.

Never remove or attempt to adjust

safety valve. Keep safety valve free from paint and other accumulations.

20.Do regular maintenance; keep all nuts, bolts, and screws tight, to be sure equipment is in safe working condition .

21.Keep cleaning rags and other flammable waste materials in a tightly closed metal container and dispose of later in the proper fashion.

22.Drain tanks of moisture after each day’s use. If unit will not be used for a while, it is best to leave drain cock open until such time as it is to be used. This will allow moisture to completely drain out and help prevent corrosion of inside of tank.

23.Inspect tank yearly for rust, pin holes or any other imperfections that could cause it to become unsafe. NEVER weld or drill holes in air tank.

Never attempt

to repair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn or damaged tanks.

Drain liquid from tank daily.

Spraying Precautions

Do not spray flammable materials

in vicinity of open flame or near ignition sources including the compressor unit.

24.Spray in a well ventilated area, to keep fumes from collecting and causing health and fire hazards.

25.Do not spray in vicinity of open flames or other places where a spark can cause ignition. Do not smoke when spraying paint, insecticides, or other flammable substances.

26.Use a respirator when spraying.

27.Do not direct paint or other sprayed material at the compressor. Locate compressor as far away from

the spraying area as possible to minimize overspray accumulation on the compressor.

28.When spraying or cleaning with solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer.

29.Do not smoke when spraying paint, insecticides, or other flammable substances.

30.Use a face mask/ respirator when

spraying and spray in a well ventilated area to prevent health and fire hazards.

31.Household use only.

32.To reduce the risk of electrical shock, do not expose to rain. Store indoors.

www.chpower.com

Image 2
Contents Description Safety GuidelinesGeneral Safety UnpackingSpraying Precautions Assembly InstallationExtension cords OperationMoisture in compressed air Maintenance Portable Air Compressors Troubleshooting Chart Do not disassemble check valve With air in tank bleed tankLimited Warranty Généralités Sur La Sécurité Directives De SécuritéDéballage Dénégation DES GarantiesPrÉcautions de pulvÉrisation Généralités Sur La Sécurité SuiteEt autres accumulations. Ceci sert à éviter la sur-pression Utiliser un respirateur pendant la pulvérisationInstallation DE Fils Assemblage’HUMIDITÉ Dans L’AIR Comprimé Installation SuiteFunctionnement Instructions DE Mise À LA TerreFunctionnement Suite EntretienGraissage ENLEVAGE, Inspection ET Remplacement DU FiltreEntretien Suite Protecteur DE Surcharge ThermiqueNe pas démonter le clapet s’il y a Guide De Dépannage15 Fr De l’air dans le réservoir purger leGarantie Limitée 16 FrPara Desempacar DescripciónMedidas De Seguridad Proposición DE CaliforniaGenerales de Seguridad Continuación 18 SpEnsamblaje InstalaciónConexion a tierra FuncionamientoHumedad en el aire comprimido Cordones de ExtensionMantenimiento ManómetrosProtector termico Para desmontar, chequear y reemplazar el filtroLubricacion AlmacenamientoAntes de desmantelar la válvula de Guía de Diagnóstico de Averías Continuación23 Sp Chequeo purgue el aire del tanqueGarantía Limitada 24 Sp