Campbell Hausfeld HS5500, HL5500 Series operating instructions Maintenance, Operation

Page 5

Operation (Continued)

3.The safety valve should automatically close at approximately 40-50 PSI. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced.

Safety valve must be replaced if it

cannot be actuated or it leaks air after ring is released.

PRESSURE GAUGES

Gauge attached to regulator indicates air pressure going to hose (and any tool attached to end of hose).

Gauge attached to pressure switch indicates air pressure in tank.

Maintenance

Disconnect power source and then release all pressure from the system before attempting to

install, service, relocate or perform any maintenance.

Check compressor often for any visible problems and follow maintenance procedures each time compressor is used.

1.Turn compressor off and release pressure from system. To release pressure from system, pull ring on ASME safety valve (see Figures 6 and 8). Deflect escaping air by shielding valve with one hand as you pull ring with other hand. Pull ring until tank is empty.

A large amount of fast moving air will

be released when the safety valve is opened with pressure in the tank. Wear ANSI approved Z87.1 safety glasses.

2.Drain moisture from tank by opening drain valve (see Figure 6) underneath tank. Tilt tank to remove all moisture.

3.Clean dust and dirt from tank, air lines and pump cover while compressor is still OFF.

OIL CHANGE

1.Allow compressor to run and warm up oil. Unplug unit.

2.Position a pan under pump end of unit.

3.Remove oil drain plug (see Figure 6). Allow oil to collect in pan. Tilt unit to completely drain.

4.Replace drain plug, fill pump to full line on sight glass. Use Chevron synthetic 5W-30, Mobil 1 5W-30 or 10W-30 synthetic motor oil. Using other types of oil will cause starting problems.

5.Change oil after every 50 hours of use.

INTAKE AIR FILTER MAINTENANCE

Removal, Inspection and Replacement (Figure 9)

Filter element

Filter

cover

Figure 9 - Intake filter maintenance

The intake filter element should be removed and checked periodically. A clogged intake filter can decrease compressor performance and cause the compressor to overheat.

1.Rotate the filter cover counter clockwise and remove .

2.Remove the filter element and inspect.

3.If the filter element is dirty or clogged, replace it.

4.Reinstall filter and cover.

IMPORTANT: Locate unit as far from spraying area as hose will allow to prevent overspray from clogging filter.

OVERLOAD PROTECTOR SECTION

This compressor is equipped with a

thermal overload protector which will shut off motor if it becomes overloaded.

If overload protector shuts motor OFF frequently, look for the following causes.

1.Low voltage.

2.Clogged air filter.

3.Lack of proper ventilation.

If the overload protector is

actuated, the motor must be allowed to cool down for 30 minutes. To reset once the motor has cooled down, turn pressure switch to the OFF position then to the AUTO position.

STORAGE

1.Drain tank of moisture.

2.When not in use, store compressor in a cool, dry place.

3.Disconnect hose and hang open ends down to allow any moisture to drain.

www.chpower.com

5

Image 5
Contents General Safety Information Safety GuidelinesDescription UnpackingAssembly General SafetySpraying Precautions Oil-Lubricated CompressorsSide view of unit Top view of unit InstallationAssembly Before Each START-UP Operating Procedure Before First START-UP BREAK-IN ProcedureAsme Safety Valve OperationOperation MaintenanceCompressor will not run Switch in OFF position Troubleshooting ChartDo not disassemble check valve With air in tank bleed tank WHO Gives this Warranty Warrantor Limited WarrantyWhat is not Covered Under this Warranty Responsibilities of Purchaser Under this WarrantyGénéralités Sur La Sécurité Directives De SécuritéDéballage Avertissement D’Air RespirableAssemblage Généralités Sur La Sécurité SuiteCompresseur Graissé par lHuile Précautions DE PulvérisationVue latérale de l’appareil Vue de dessus de l’appareil Assemblage SuiteAvant LE Premier Démarrage Procédure DE Rôdage FonctionnementAvant Chaque Démarrage Procédure DE Fonctionnement Soupape DE Sûreté AsmeEntretien Fonctionnement Suite14 Fr Guide De Dépannage15 Fr Guide De Dépannage SuiteGarantie Accordée PAR Garant Garantie LimitéeLA Présente Garantie NE Couvre PAS Responsabilités DE L’ACHETEUR AUX Termes DE Cette GarantieMedidas de Seguridad DescripciónPara Desempacar ¡NO Devuelva EL ALTO! Producto AL MinoristaCompresor lubricado con aceite EnsamblajeContinuacíon Precauciones Para RociarVista lateral de la unidad Vista superior de la unidad InstalaciónEnsamblaje Continuacíon Compresor lubricado con aceite Instalación Continuacíon FuncionamientoHumedad EN EL Aire Comprimido Antes DE Cada Procedimiento DE Arranque FuncionamientoMantenimiento 22 Sp Guía de diagnóstico de averías23 Sp Guía de diagnóstico de averías ContinuaciónResponsabilidades DEL Comprador Bajo Esta Garantía Garantía LimitadaLO QUE no Está Cubierto POR Esta Garantía