Plenty of fresh water and soap must be ready at hand so that in case of acid coming in contact with skin, eyes and clothes, the areas in question can be thoroughly washed.

If acid enters the eyes, you must thoroughly wash them with cold running water for at least 15 minutes. It is recommended that you immediately consult a medical doctor.

Baking powder neutralizes battery acid electrolyte. Always keep some at hand.

Special care must be taken when working with metal tools near or on the batteries. With tools such as screwdrivers, spanners etc. short-circuits can result. Sparks produced by the short circuit can cause an explosion.

When working on batteries all personal metal items such as rings, necklaces and bracelets must be removed. Batteries are so powerful that short-circuit with these items can melt them and thus cause severe burns. Always follow the battery manufacturer instructions.

Under certain conditions HP-COMPACT or a connected generator can start automatically. While working on an electrical installation you must ensure that these appliances are disconnected beforehand from the installation.

2 Introduction

The HP-COMPACT is a sine wave inverter with integrated battery charger with many additional functions, it has been developed to be used as stand-alone (no grid- feeding) AC provider, or as continuous / break-free current supply provider (UPS).

2.1Principle schematic

Notes:

(1)The neutral of the appliance is not connected to the earth whatever the function mode is. If requested and according to the local regulation, an automatic

HP-COMPACT V5.4

7/80

Image 5
Contents HP-COMPACT HPC Sine wave Inverter, Battery charger, TransfersystemHP-COMPACT Warranty Disclaimer Quality and WarrantyGeneral Information Operating instructionsLiability Disclaimer Special precautionsIntroduction Principle schematicDescription of the main functions Battery connecting Installation place Mounting and installingFixing ConnectionsCabling Pre-installation settingsConnection to battery 3.6.1.1 On the appliance side Connection to Temperature Sensor Temp Connection to Remote controlConnection to the 230Vac-consumer appliances AC Output Connection to the 230Vac Input AC InputDisplay and control parameters ControlLED Light Emitting Diodes LEDTurning Knobs Push buttonsInverter Charge detection system „StandbyOverheating Over Temp Battery ConditionDefault values for battery voltage thresholds Battery chargerCycle of charge Equalization chargingCharging current Input current repartition Power sharingSet the Input Limit Transfer system Delayed mode of the Transfer System Fast UPS- Mode for the Transfer SwitchMultifunctional Contact Set the transfer voltage thresholdHP-COMPACT Remote Control RCC-01Programming Remote control for „Power Sharing RPS-01Standard setting Set the voltage and timing threshold Reset value default settingsBattery voltages and absorption time Table of voltage and timing threshold Auxiliary contactPrinciple Programming of the Auxiliary ContactManual operating of Auxiliary Contact Power cut of the second priority loadsDiagram of the different modes Installation MaintenanceDisabling some of the HP-COMPACT functions Declaration of CE ComplianceTechnical Data