Sterling Plumbing 882 00276.00 specifications Control System Order Numbers

Page 77

Control System Order Numbers

Fuse

Size

Voltage

Amps

F1

5X20

250 V

5 A

F2

1/4X1

1/4-250 V

4 A

F3

5X20

250 V

0.5 A

F4

5X20

250 V

0.5 A

F5

5X20

250 V

0.5 A

F7

5X20

250 V

0.5 A

Type

Metric

Time Delay

Time Delay

Metric

Metric

Metric

Part Number

A0571836

CT99107

CT96398

CT102258

CT102259

A0571836

77

Image 77
Contents SDD Series Digital Dosing Additive Feeders Table of Contents Introduction Digital Dosing Units Keypad and LED Display ControllerKeys and Symbols Symbols Mounting Quick Start-upUnpacking DD Discs Calibration Number Recipe Setup for Injection MoldingDT Discs Calibration Number DP DiscsCalibration Recipe Setup for ExtrusionDigital Dosing Units Input Number Manufacturer Motor ColorDigital Dosing Units Digital Dosing Units Digital Dosing Units RPM Digital Dosing Units Digital Dosing Units Digital Dosing Units Initial Installation Initial Installation and OperationElectrical Diagram Electrical diagram of connectionsSignal Converter with AC Power Supply Extruder Follower Interface Signal ConverterDiagram of analog inputs Initial Operation Signal Converter with DC Power SupplyVDC Mini Power Supply Recipe Input Injection Molding Injection MoldingStep Step Step Operation Injection Molding Recipe Input Extrusion Constant Extrusion Constant StandardExtrusion Constant, parameter 3 is skipped Step Step Operation Extrusion Constant Recipe Input Extrusion Proportional Extrusion Proportional Extruder Follower OptionStep Step Operation Extrusion Proportional Extruder Follower Option Calibration Determining the Calibration WeightRepeat steps 3 and 4 four 4 more times Digital Dosing Units Recipe Storage Advanced Operations/ Control FunctionsRecipe Storage and Recall Recipe Recall Clearing the Totalizer Acknowledging AlarmsLevel switches probes AlarmsCommunication Protocol Interfaces Maintenance Intervals MaintenanceRemoving the Shear plate DD feeder only Removing the shear plateDismantling the Dosing Station Cleaning the DD Digital Dosing StationInstalling the shear plate Installing the Dosing Station Removing the Dosing Disc Installing the Dosing DiscChanging the Dosing Disc in the DT Digital Dosing Station DD Discs Installing Different Types of Dosing DiscsRemoving / Replacing the Wiper in the DT Dosing Station Cleaning the DT Dosing Station Disc Exchangeable StationsDP Discs Calibration See Appendix D for fuse part numbers Replacing FusesMalfunctions Error Codes Appendix a TroubleshootingGeneral Troubleshooting Unit Will Not Operate Error Codes Recipe Formulas Determining the Software Setup FactorInjection Molding Recipe Limitations for Injection MoldingRecipe Limitations Extrusion ExtrusionMax. input frequency = Hz Appendix B Basic Parameter SettingsExtrusion Mode Example Probe Example Digital Dosing Units Disc Dosing Factor Disc Guide 20 kg/h DT30 204010F Default Calibration # 150 grams/rev One 1 for Granule Disc Dosing Factor TableProcessing Option Hopper Level Probe VirginStarter Calibration Parameters Set-up of Factory Set Operating Parameters Ext = Span factor sf calculated using sf=1000/rpm@10vdc Page Station 1 Digital Dosing Unit Side View TOP View Station 2 Digital Dosing UnitGeneral Wiring Diagram for Bauer Motor Page C150 Controller Injection Dosing Disc/Shear Order Numbers Appendix D Spare Parts ListReplacement Motor Order Numbers Control System Order Numbers Page Technical Assistance Service DepartmentParts Department Sales Department