Sterling Plumbing 882 00276.00 specifications Probe

Page 60

Throughput: 8000 g/min

Totalizer displayed in lbs

Extrusion mode

Raw material probe .

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . 1

 

 

1

 

 

 

Additive

probe

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . 2

 

 

2

 

 

 

 

Blending

unit

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . 8

 

__

 

Totalizer

displayed in lb

. . . .. . . . . . . . . . . .16

 

16

 

 

Extruder throughput

(1 kg-6.5 Kg/min)

(2.2 lbs/min-14.3 lbs/min) …….0

___

Extruder throughput

(10 kg-65 kg/min)……….(22 lbs/min-143 lbs/min).

. 32. . .

32

Extruder throughput

(0.1 kg-0.65 Kg/min) . . .(0.22 lbs/min-1.43 lbs/min)….128

___

External

run/stop signal controls dosing

. . . . . . . . . . . . . . . 64

 

___

 

Mounting

on a Micro mixing-hopper

. . . . . . . . . . . . . . 256

 

___

 

Alarm

output switched in case of power failure

. . . . . . . . . . . . . . .512

 

___

 

Extrusion

mode

. . . . . . . . . . . . . . 1024

 

1024

 

Printer

available . . . .

. . . . . . . . . . . . . . . . . .. .

. . . . . . . . . . . . . . . 16348

____

 

Configuration value:

1075

 

Injection Molding:

Mark the functions required. Use the numerical value indicated and insert it in the empty field if applicable. Total the figures for configuration value.

Optional raw material level probe installed

1

___

Optional additive level probe installed

2

___

Digital Dosing Units

60

Image 60
Contents SDD Series Digital Dosing Additive Feeders Table of Contents Introduction Digital Dosing Units Controller Keypad and LED DisplayKeys and Symbols Symbols Quick Start-up UnpackingMounting Recipe Setup for Injection Molding DD Discs Calibration NumberDT Discs Calibration Number DP DiscsRecipe Setup for Extrusion CalibrationDigital Dosing Units Manufacturer Motor Color Input NumberDigital Dosing Units Digital Dosing Units Digital Dosing Units RPM Digital Dosing Units Digital Dosing Units Digital Dosing Units Initial Installation and Operation Initial InstallationElectrical diagram of connections Electrical DiagramExtruder Follower Interface Signal Converter Diagram of analog inputsSignal Converter with AC Power Supply Signal Converter with DC Power Supply VDC Mini Power SupplyInitial Operation Injection Molding Recipe Input Injection MoldingStep Step Step Operation Injection Molding Extrusion Constant Standard Recipe Input Extrusion ConstantExtrusion Constant, parameter 3 is skipped Step Step Operation Extrusion Constant Extrusion Proportional Extruder Follower Option Recipe Input Extrusion ProportionalStep Step Operation Extrusion Proportional Extruder Follower Option Determining the Calibration Weight CalibrationRepeat steps 3 and 4 four 4 more times Digital Dosing Units Advanced Operations/ Control Functions Recipe Storage and RecallRecipe Storage Recipe Recall Acknowledging Alarms Clearing the TotalizerAlarms Level switches probesCommunication Protocol Interfaces Maintenance Maintenance IntervalsRemoving the Shear plate DD feeder only Removing the shear plateCleaning the DD Digital Dosing Station Installing the shear plateDismantling the Dosing Station Installing the Dosing Station Installing the Dosing Disc Changing the Dosing Disc in the DT Digital Dosing StationRemoving the Dosing Disc Installing Different Types of Dosing Discs Removing / Replacing the Wiper in the DT Dosing StationDD Discs Cleaning the DT Dosing Station Exchangeable Stations DP Discs CalibrationDisc Replacing Fuses See Appendix D for fuse part numbersAppendix a Troubleshooting General Troubleshooting Unit Will Not OperateMalfunctions Error Codes Error Codes Determining the Software Setup Factor Recipe FormulasInjection Molding Recipe Limitations for Injection MoldingExtrusion Recipe Limitations ExtrusionAppendix B Basic Parameter Settings Extrusion ModeMax. input frequency = Hz Example Probe Example Digital Dosing Units Disc Dosing Factor Disc Guide 20 kg/h DT30 204010F Default Calibration # 150 grams/rev Disc Dosing Factor Table One 1 for GranuleProcessing Option Hopper Level Probe VirginStarter Calibration Parameters Set-up of Factory Set Operating Parameters Ext = Span factor sf calculated using sf=1000/rpm@10vdc Page Station 1 Digital Dosing Unit Station 2 Digital Dosing Unit Side View TOP ViewGeneral Wiring Diagram for Bauer Motor Page C150 Controller Injection Appendix D Spare Parts List Replacement Motor Order NumbersDosing Disc/Shear Order Numbers Control System Order Numbers Page Service Department Technical AssistanceParts Department Sales Department