Setup
Adjust Phasing
003
002
001
Key:ti12389a
001Piston Shaft
002Locking Nut
003Phase Adjustment Screw
9.Watch the dispense valve carefully to observe which material is dispensed first. Press the Dispense
Request button () or the footswitch to dispense material.
10.If the materials do not exit the dispense valve at the same time, adjust the piston Phase Adjustment Screw (003) as follows.
•If the A side material exits the dispense nozzle
before the B side material ( ):
a.Use two 13 mm wrenches to break loose the locking nut (002) from the phase adjust- ment screw (003) on the B material side.
b.Hold the phase adjustment screw (003) sta- tionary with a 13 mm wrench.
c.Use a 7 mm wrench to turn the piston shaft (001) counterclockwise 1/4 turn or less to move the B piston forward.
•If the B side material exits the dispense nozzle
before the A side material ( ):
a.Use two 13 mm wrenches to break loose the locking nut (002) from the phase adjust- ment screw (003) on the A material side.
b.Hold the phase adjustment screw (003) sta- tionary with a 13 mm wrench.
c.Use a 7 mm wrench to turn the piston shaft (001) counterclockwise 1/4 turn or less to move the A piston forward.
NOTE: It is highly recommended that all of the phasing adjustment be done to one side or the other; not both.
NOTE: Ensure the piston shaft and phase adjustment screw do not rotate while tightening the locking nut (002) in the following step.
11.Hold piston shaft (001) and phase adjustment screw (003) in place with a 7 mm and 13 mm wrench and tighten locking nut (002) against phase adjustment screw with a 13 mm wrench.
12.Watch the dispense valve carefully to observe which material is dispensed first. Press the Dispense
Request button ( ) or the foot switch to dispense material. If one material exits the dispense nozzle before the other, go back to step 10.
Exit Calibration Mode
13.Navigate to the Shot Mode Screen or Operator Mode Screen.
30 | 334135B |