Graco 334135B Maintenance Mode Run Screen, Shot Amount or Stroke % Adjust Screen

Page 63

Maintenance Mode Run Screen

Used for machine testing. The user will be able to extend or retract the pump, or open and close the dis- pense valve from this screen. Once the user has navi- gated to function to be implemented, the user simply needs to press the dispense request key to issue the request.

Shot Amount or Stroke % Adjust Screen

If in shot mode, and the user has enabled this run screen adjustment (via a setup screen option), the user can adjust the shot amount by simply pressing the Up or Down arrow keys, then pressing the accept user entry softkey. The minimum percent required is 15 percent.

Run Screen while Dispensing

Additional information is provided during a dispense operation, consisting of a progress bar representing the current % complete of the dispense operation (shot mode only), and the amount of time elapsed for a dis- pense. During a dispense, the run screen programming options are no longer available. Once the dispense is completed, the screen will return to the main home run screen.

Appendix B - LCM Run Screen Overview

Error Code Acknowledgement Screen

This screen will be generated if an error condition becomes active. The screen will contain the code for the condition, a graphic describing the condition, the standard Graco alarm bell, and a soft key prompting the user to acknowledge the condition. Once the condition has been acknowledged by the user, the screen will return to the main run screen. If the condition is still present after acknowledgement, the code previously presented to the user will be displayed on the bottom left hand corner of the main run screen. Once the condition is corrected, the code displayed will be removed.

334135B

63

Image 63
Contents PR70e Important Safety InstructionsContents Related Manuals ModelsElectric Shock Hazard Fire and Explosion Hazard Component Identification MachineIG Machine Key AB System Shut-Down Key Local Control Module LCMScreen Overview and Appendix C LCM Setup LCM Screen NavigationRun Screen Component Identification 334135B Gun Mounted MD2 Valves, LC0120 and LC0122 Recommended PartsDispense Valve Standard Dispense Valves, 255179Part Description Quantity Lever Actuated MD2 Valves, LC0121 and LC0123Mixers Package Description Reference Number and Description1301 1302 1303 Mixer ShroudPart Description Mounting, valve, HMI Mounting, HMI Applicator MountingAir Filter and Ball Valve, 24R707 High Temperature Grease FootswitchTanks Quantity Part Description 24W415 24W416 24W417 Unheated, Non-Recirculating Hose Hose PackagesRecommended Parts 334135B Nylon Piston, Stainless Steel Metering Tube Assemblies Piston PackageUhmw Uhmw Piston, Stainless Steel Metering Tube AssembliesShot Size cc Air Motor In. Air Motor Pump Tube Combination InformationGeneral Grounding Guidelines InstallationMachine Installation GroundingInstall the Dispense Valve and Support Arm, if needed Install the Chemical HosesElectrical Requirements Ground SystemPiston Position Calibration SetupManually Move the Piston Drive Block Perform Pressure Relief Procedure onNavigate to the Shot Mode Screen or Operator Mode Screen Engaged Piston PositionPrime Dispense Head Prime the Dispense HeadNavigate to the Phasing Shot Calibration Screen Phasing AdjustmentAdjust Dispense Quantity Prepare the MachineAdjust Phasing Adjust Dispense Valve Snuff Back Operator Mode Screen Adjust Open Dispense Valve ODV TimingStartup Pressure Relief ProcedureNavigate to the Maintenance Mode Run Screen OperationShutdown Relieve pressure. See Pressure Relief Procedure,Schedule MaintenanceClean the Pump Shafts Disassemble and Clean the Dispense HeadRemove Access Panel Install Upgrade TokenProblem Cause Solution TroubleshootingProblem Cause Solution Entries in Position Calibra LCM Error CodesTrigger Code Name Type Causes Fixes ConditionHydraCheck Kit Installation, 24W336 Prepare Machine for Kit InstallationRepair Install Adjustment Screw/Cap Adjust the Adjustment Screw/CapAdjust Shock Resistance Disassemble the Air Cylinder Air Cylinder Rebuild InstructionsRe-Assemble the Air Cylinder Clean and Inspect the PartsRear Pump Rebuild Instructions Prepare for Operation Assemble the Rear Pump AssemblyPiston/Cylinder Replacement Kit Installation Install CylinderDisassemble Cylinder Check Valve Rebuild Kit Installation Fixed Ratio Base Parts24V935, Pump 24V936, Pump Part Description Assembly Pump Sub-Assembly, 24S053 Collar Check Valve, Assembly LC0093206 201 204 205 202 203 Fixed Ratio Drive Block Assembly, LC010724V933, Motor 24V934, Motor Part Description Air Air Cylinder, 24V933Fixed Ratio Frame Sub-Assembly, LC0290 Ring, support Carbide Package Pump Piston Washer Screw Ball Uhmw Piston, Ceramic Metering Tube AssembliesElectrical Schematics SchematicsElectrical Schematic Pneumatic Schematic DB25 Pin FunctionDB25 Pin Number Pin Function Description Schematics 334135B Appendix a LCM Icon Overview Amount Adjust Phasing Shot AdjustPosition Adjust AdjustMode Selection Programming Screen Splash Screen Operator Mode ScreenDisable Mode Screen Shot Mode ScreenRun Screen while Dispensing Maintenance Mode Run ScreenShot Amount or Stroke % Adjust Screen Error Code Acknowledgement ScreenAppendix C LCM Setup Screen Overview Setup Screen Password Set/Clear ScreenPhasing Shot Calibration Screen LCE Piston Size mm2 Nylon and Uhmw Piston Replacement KitsKits LCF Piston Size mm2MD2 Valve Recommended Spare PartsDimensions Dimensions Technical Data Graco Information Graco Standard Warranty