Graco 334135B important safety instructions Appendix a LCM Icon Overview

Page 60

Appendix A - LCM Icon Overview

Appendix A - LCM Icon Overview

Icon

Label

Description

 

 

 

 

 

 

Power On

When the corresponding soft key is pressed, the PR70 will exit disable mode

 

 

 

and enter the last mode used (Shot or manual) and display the corresponding

 

 

 

mode on the home run screen.

 

 

 

 

 

 

Shot Mode Designa-

Used on main home screen to indicate the machine is in shot mode. On the

 

 

tion

maintenance mode screen, it also indicates the user wants to either close or

 

 

 

open the machine dispense valve.

 

 

 

 

 

 

Operator Mode Des-

Used on main home screen to indicate the machine is in Manual mode.

 

 

ignation

 

 

 

 

 

 

 

Maintenance Mode

Used on main home screen to indicate the machine is in Maintenance mode.

 

 

Designation

 

 

 

 

 

 

 

Mode Select Desig-

When the corresponding soft key is pressed, the machine will enter a mode

 

 

nation

select run screen.

 

 

 

 

 

 

Setup Screen Desig-

When the corresponding soft key is pressed, the machine will enter the start of

 

 

nation

the setup screens for the machine.

 

 

 

 

 

 

Next Field Designa-

When the corresponding soft key is pressed, the user will navigate into a

 

 

tion

screen or to the next field within a screen.

 

 

 

 

 

 

Accept User Entry

When the corresponding soft key is pressed, the user accepts the value(s) or

 

 

 

options shown on the screen.

 

 

 

 

 

 

Abort User Entry

When the corresponding soft key is pressed, the user aborts the value(s) or

 

 

 

options shown on the screen. Activating this option will essentially allow the

 

 

 

user to go back one step in the programming or screen navigation sequence.

 

 

 

 

 

 

Stuck Key

Graphic used to indicate that the control has detected that one of the keys is

 

 

 

 

 

stuck in the ON position.

 

 

 

 

 

 

 

 

 

 

Bad Linear Sensor

Graphic used to indicate that the control has detected that readings from the

 

 

 

linear position sensor are invalid.

 

 

 

 

 

 

Improper Machine

Graphic used to indicate that the control has no or invalid readings for the

 

 

Calibration

extend, retract and metering tube positions.

 

 

 

 

 

 

Retract Position

Graphic used to indicate the full retract position of the pump.

 

 

 

 

 

 

Extend Position

Graphic used to indicate the full extend position of the pump.

 

 

 

 

 

 

Metering Tube

Graphic used to indicate the position on the pump where the piston first enters

 

 

Entrance Position

the pump metering tube.

 

 

 

 

60

334135B

Image 60
Contents Important Safety Instructions PR70eContents Models Related ManualsElectric Shock Hazard Fire and Explosion Hazard Component Identification MachineIG Machine Key Local Control Module LCM AB System Shut-Down KeyScreen Overview and Appendix C LCM Setup LCM Screen NavigationRun Screen Component Identification 334135B Recommended Parts Dispense ValveStandard Dispense Valves, 255179 Gun Mounted MD2 Valves, LC0120 and LC0122Lever Actuated MD2 Valves, LC0121 and LC0123 Part Description QuantityMixers Reference Number and Description 1301 1302 1303 MixerShroud Package DescriptionApplicator Mounting Part Description Mounting, valve, HMI Mounting, HMIHigh Temperature Grease Footswitch Air Filter and Ball Valve, 24R707Tanks Quantity Part Description 24W415 24W416 24W417 Hose Packages Unheated, Non-Recirculating HoseRecommended Parts 334135B Piston Package Nylon Piston, Stainless Steel Metering Tube AssembliesUhmw Piston, Stainless Steel Metering Tube Assemblies UhmwPump Tube Combination Information Shot Size cc Air Motor In. Air MotorInstallation Machine InstallationGrounding General Grounding GuidelinesInstall the Chemical Hoses Install the Dispense Valve and Support Arm, if neededGround System Electrical RequirementsSetup Piston Position CalibrationPerform Pressure Relief Procedure on Navigate to the Shot Mode Screen or Operator Mode ScreenEngaged Piston Position Manually Move the Piston Drive BlockPrime the Dispense Head Prime Dispense HeadPhasing Adjustment Adjust Dispense QuantityPrepare the Machine Navigate to the Phasing Shot Calibration ScreenAdjust Phasing Adjust Dispense Valve Snuff Back Adjust Open Dispense Valve ODV Timing Operator Mode ScreenPressure Relief Procedure Navigate to the Maintenance Mode Run ScreenOperation StartupRelieve pressure. See Pressure Relief Procedure, ShutdownMaintenance Clean the Pump ShaftsDisassemble and Clean the Dispense Head ScheduleInstall Upgrade Token Remove Access PanelTroubleshooting Problem Cause SolutionProblem Cause Solution LCM Error Codes TriggerCode Name Type Causes Fixes Condition Entries in Position CalibraHydraCheck Kit Installation, 24W336 Prepare Machine for Kit InstallationRepair Install Adjustment Screw/Cap Adjust the Adjustment Screw/CapAdjust Shock Resistance Air Cylinder Rebuild Instructions Disassemble the Air CylinderClean and Inspect the Parts Re-Assemble the Air CylinderRear Pump Rebuild Instructions Assemble the Rear Pump Assembly Prepare for OperationPiston/Cylinder Replacement Kit Installation Install CylinderDisassemble Cylinder Check Valve Rebuild Kit Installation Parts Fixed Ratio Base24V935, Pump 24V936, Pump Part Description Assembly Pump Sub-Assembly, 24S053 Check Valve, Assembly LC0093 CollarFixed Ratio Drive Block Assembly, LC0107 206 201 204 205 202 203Air Cylinder, 24V933 24V933, Motor 24V934, Motor Part Description AirFixed Ratio Frame Sub-Assembly, LC0290 Uhmw Piston, Ceramic Metering Tube Assemblies Ring, support Carbide Package Pump Piston Washer Screw BallSchematics Electrical SchematicsElectrical Schematic Pneumatic Schematic DB25 Pin FunctionDB25 Pin Number Pin Function Description Schematics 334135B Appendix a LCM Icon Overview Phasing Shot Adjust Position AdjustAdjust Amount AdjustSplash Screen Operator Mode Screen Disable Mode ScreenShot Mode Screen Mode Selection Programming ScreenMaintenance Mode Run Screen Shot Amount or Stroke % Adjust ScreenError Code Acknowledgement Screen Run Screen while DispensingAppendix C LCM Setup Screen Overview Setup Screen Password Set/Clear ScreenPhasing Shot Calibration Screen Nylon and Uhmw Piston Replacement Kits KitsLCF Piston Size mm2 LCE Piston Size mm2Recommended Spare Parts MD2 ValveDimensions Dimensions Technical Data Graco Standard Warranty Graco Information