Graco 334135B important safety instructions Hose Packages, Unheated, Non-Recirculating Hose

Page 18

Recommended Parts

Hose Packages

Unheated, Non-Recirculating Hose

1404

1403

1401

1402

 

ti12446a

 

Assembly LC0801 Shown

 

 

 

 

 

 

1 Apply thread sealant tape to male npt threads before assembly.

 

 

 

 

 

 

 

 

 

Reference Number and Description

 

 

 

 

 

 

 

 

 

1401

1402

1403

1404

 

 

 

 

 

 

Hose Package

Description

Hose Assembly

90 Deg Elbow

Adapter

Bushing

 

 

 

 

 

 

LC0801

3/16 in. x 30 in.

16C501

94/0144-S/25

94/1000/98

94/0488/98

LC0802

3/16 in. x 120 in.

16C506

94/0144-S/25

94/1000/98

94/0488/98

LC0803

3/16 in. x 180 in.

16C507

94/0144-S/25

94/1000/98

94/0488/98

LC0804

1/4 in. x 30 in.

16C510

94/0148-S/25

J6900040

 

LC0805

1/4 in. x 120 in.

16C515

94/0148-S/25

J6900040

 

LC0806

1/4 in. x 180 in.

16C516

94/0148-S/25

J6900040

 

LC0807

3/8 in. x 30 in.

16C519

94/0149-S/25

94/1007/98

 

LC0808

3/8 in. x 120 in.

16C524

94/0149-S/25

94/1007/98

 

LC0809

3/8 in. x 180 in.

16C525

94/0149-S/25

94/1007/98

 

LC0400*

3/8 in. x 30 in.

16D261

94/0149-S/25

94/1007/98

 

LC0401*

3/8 in. x 120 in.

16D266

94/0149-S/25

94/1007/98

 

LC0402*

3/8 in. x 180 in.

16D267

94/0149-S/25

94/1007/98

 

LC0810

1/2 in. x 30 in.

16C529

94/0150-S/25

94/1009/98

 

LC0811

1/2 in. x 120 in.

16C534

94/0150-S/25

94/1009/98

 

LC0812

1/2 in. x 180 in.

16C535

94/0150-S/25

94/1009/98

 

LC0403*

1/2 in. x 30 in.

16D271

94/0150-S/25

16C399

 

LC0404*

1/2 in. x 120 in.

16D276

94/0150-S/25

16C399

 

LC0405*

1/2 in. x 180 in.

16D277

94/0150-S/25

16C399

 

LC0813

3/4 in. x 120 in.

16C544

94/0153-S/25

94/1083/98

 

LC0814

3/4 in. x 180 in.

16C545

94/0153-S/25

94/1083/98

 

LC0406*

3/4 in. x 120 in.

16D286

94/0153-S/25

94/1083/98

 

LC0407*

3/4 in. x 180 in.

16D287

94/0153-S/25

94/1083/98

 

Quantity

1

1

1

1

 

 

 

 

 

 

*High pressure hoses (3500 psi, 24 MPa, 241 bar)

18

334135B

Image 18
Contents Important Safety Instructions PR70eContents Models Related ManualsElectric Shock Hazard Fire and Explosion Hazard Component Identification MachineIG Machine Key Local Control Module LCM AB System Shut-Down KeyScreen Overview and Appendix C LCM Setup LCM Screen NavigationRun Screen Component Identification 334135B Standard Dispense Valves, 255179 Recommended PartsDispense Valve Gun Mounted MD2 Valves, LC0120 and LC0122Lever Actuated MD2 Valves, LC0121 and LC0123 Part Description QuantityMixers Shroud Reference Number and Description1301 1302 1303 Mixer Package DescriptionApplicator Mounting Part Description Mounting, valve, HMI Mounting, HMIHigh Temperature Grease Footswitch Air Filter and Ball Valve, 24R707Tanks Quantity Part Description 24W415 24W416 24W417 Hose Packages Unheated, Non-Recirculating HoseRecommended Parts 334135B Piston Package Nylon Piston, Stainless Steel Metering Tube AssembliesUhmw Piston, Stainless Steel Metering Tube Assemblies UhmwPump Tube Combination Information Shot Size cc Air Motor In. Air MotorGrounding InstallationMachine Installation General Grounding GuidelinesInstall the Chemical Hoses Install the Dispense Valve and Support Arm, if neededGround System Electrical RequirementsSetup Piston Position CalibrationEngaged Piston Position Perform Pressure Relief Procedure onNavigate to the Shot Mode Screen or Operator Mode Screen Manually Move the Piston Drive BlockPrime the Dispense Head Prime Dispense HeadPrepare the Machine Phasing AdjustmentAdjust Dispense Quantity Navigate to the Phasing Shot Calibration ScreenAdjust Phasing Adjust Dispense Valve Snuff Back Adjust Open Dispense Valve ODV Timing Operator Mode ScreenOperation Pressure Relief ProcedureNavigate to the Maintenance Mode Run Screen StartupRelieve pressure. See Pressure Relief Procedure, ShutdownDisassemble and Clean the Dispense Head MaintenanceClean the Pump Shafts ScheduleInstall Upgrade Token Remove Access PanelTroubleshooting Problem Cause SolutionProblem Cause Solution Code Name Type Causes Fixes Condition LCM Error CodesTrigger Entries in Position CalibraHydraCheck Kit Installation, 24W336 Prepare Machine for Kit InstallationRepair Install Adjustment Screw/Cap Adjust the Adjustment Screw/CapAdjust Shock Resistance Air Cylinder Rebuild Instructions Disassemble the Air CylinderClean and Inspect the Parts Re-Assemble the Air CylinderRear Pump Rebuild Instructions Assemble the Rear Pump Assembly Prepare for OperationPiston/Cylinder Replacement Kit Installation Install CylinderDisassemble Cylinder Check Valve Rebuild Kit Installation Parts Fixed Ratio Base24V935, Pump 24V936, Pump Part Description Assembly Pump Sub-Assembly, 24S053 Check Valve, Assembly LC0093 CollarFixed Ratio Drive Block Assembly, LC0107 206 201 204 205 202 203Air Cylinder, 24V933 24V933, Motor 24V934, Motor Part Description AirFixed Ratio Frame Sub-Assembly, LC0290 Uhmw Piston, Ceramic Metering Tube Assemblies Ring, support Carbide Package Pump Piston Washer Screw BallSchematics Electrical SchematicsElectrical Schematic Pneumatic Schematic DB25 Pin FunctionDB25 Pin Number Pin Function Description Schematics 334135B Appendix a LCM Icon Overview Adjust Phasing Shot AdjustPosition Adjust Amount AdjustShot Mode Screen Splash Screen Operator Mode ScreenDisable Mode Screen Mode Selection Programming ScreenError Code Acknowledgement Screen Maintenance Mode Run ScreenShot Amount or Stroke % Adjust Screen Run Screen while DispensingAppendix C LCM Setup Screen Overview Setup Screen Password Set/Clear ScreenPhasing Shot Calibration Screen LCF Piston Size mm2 Nylon and Uhmw Piston Replacement KitsKits LCE Piston Size mm2Recommended Spare Parts MD2 ValveDimensions Dimensions Technical Data Graco Standard Warranty Graco Information