All rights reserved | Saw V1.4.doc |
Copyright ♥ Siemens AG 2008 | Manual SIMOTION Flying |
| Section E: Appendix |
| Error messages |
Flying Saw with SIMOTION | |
ErrorID | Explanation |
error code |
|
C091 | Manual to Disable |
| Error when stopping the FlyingSawAxis ( move mit v=0) |
| Details in FS_Var structure under RetDINT_stop_FSA |
C092 | Manual to Disable |
| Error when stopping the FlyingSawAxis ( move mit v=0) |
| Details in FS_Var structure under FR_stop_FSA |
C0A1 | Manual to Starting position |
| Error when positioning the FlyingSawAxis ( _pos ) |
| Details in FS_Var structure under RetDINT_pos_FSA |
C0A2 | Manual to Starting position |
| Error when positioning the FlyingSawAxis ( _pos ) |
| Details in FS_Var structure under FR_pos_FSA |
C0F1 | Incorrect mode selection from “error” mode |
C0F2 | Incorrect mode selection from “disable” mode |
C0F3 | Incorrect mode selection from “starting position” mode |
C0F4 | Incorrect mode selection from “automatic” mode |
C0F5 | Incorrect mode selection from “manual” mode |
C101 | Parameterizing error at the flying saw axis |
| Axis is not parameterized as synchronous axis. |
C201 | Parameterizing error at the material axis/external encoder |
| The material master (leading) value is neither a positioning axis |
| nor an external encoder |
V 1.4 | Release 06/06/08 | 105/107 |