•Please set these parameters corresponding to the system layout and configuration.
7.4.2Axis, material web
Configuration
•Insert a new axis with the name MaterialAxis
•Parameterize the axis as positioning axis
•Set the axis type as linear
•Parameterize as modulo axis with a modulo length greater than the maximum product length
•All of the additional parameters should be set corresponding to the drive and encoder data.
Mechanical system
•For the parameter “distance for each spindle revolution”, the distance that the material web moves through for one revolution of the drive roll should be entered.
•Appropriately supplement the other parameters as well as geometry and design.
Pre-assignment - limits
•Please enter these parameters corresponding to the system / drive relationships.
Referencing (homing)
•Parameterize “not required”
Monitoring functions –
•Please set these parameters corresponding to the system layout and configuration.
V 1.4 | Release 06/06/08 | 77/107 |