Hitachi SJ2002 manual Inverter Keypad Operation, Hitachi

Page 11

Inverter Keypad Operation

Run Key Enable LED

Parameter Display

Program/Monitor LED

Run/Stop LED

 

HITACHI

POWER

 

ALARM

5

 

Hz

 

 

 

A

 

RUN

STOP PRG

RUN RESET

FUNC. 1 2 STR

Power LED

Alarm LED

Display Units LEDs

Hertz

Amperes

Potentiometer

Enable LED

Potentiometer

Stop/Reset Key

Run Key

Up/Down Keys

Store Key

Function Key

Run/Stop LED – ON when the inverter output is ON and the motor is developing torque, and OFF when the inverter output is OFF (Stop Mode).

Program/Monitor LED – ON when the inverter is ready for parame- ter editing (Program Mode). It is OFF when the parameter display is monitoring data (Monitor Mode).

Run Key Enable LED – ON when the inverter is ready to respond to the Run key, OFF when the Run key is disabled.

Run Key – Press this key to run the motor (the Run Enable LED must be ON first). Parameter F004, Keypad Run Key Routing, determines whether the Run key generates a Run FWD or Run REV command.

Stop/Reset Key – Press this key to stop the motor when it is running (uses the programmed deceleration rate). This key will also reset an alarm which has tripped.

Potentiometer – Allows an operator to directly set the motor speed when the potentiometer is enabled for output frequency control.

Potentiometer Enable LED – ON when the potentiometer is enabled for value entry.

(continued, next page...)

9

Image 11
Contents SJ2002 Series Inverter Quick Reference Guide Page UL Cautions, Warnings, and Instructions Wiring Warnings for Electrical Practices and Wire SizesAWG Terminal Tightening Torque and Wire SizeFuse and Circuit Breaker Sizes Wire ConnectorsMotor Overload Protection HFU2 Power Circuit Terminals Description Ratings and Notes Control Circuit TerminalsAL2 SJ200 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Program ModeStep Description Via Keypad Via Logic Terminals Powerup TestBasic Error Codes Error CodesE60 Error Trip ConditionsRestoring Factory Default Settings Group Monitoring Functions Parameter TablesTrip History and Inverter Status Monitor ModeGroup Standard Functions Group Main Profile ParametersFunc Default Set Name / Description Value Code Gain setting AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C052 PID FBV function high limit C082 OI input span calibration Group Expansion Card Functions Group Motor Constants FunctionsIntelligent Input Terminal Listing Symbol Code Input Terminal NameIntelligent Output Terminal Listing Analog Input ConfigurationOption Function Name Description Corresponding Code Analog Output Function Listing