Caution: Be sure to read the SJ2002 Inverter Manual and follow its Cautions and Warnings for the initial product installation. This Quick Reference Guide is intended for reference use by experienced users in servicing existing installations.

UL® Cautions, Warnings, and Instructions

Wiring Warnings for Electrical Practices and Wire Sizes

The Cautions, Warnings, and instructions in this section summarize the procedures necessary to ensure an inverter installation complies with Underwriters Laboratories® guidelines.

Warning: “Use 60/75°C Cu wire only” or equivalent.

Warning: “Open Type Equipment.”

Warning: “Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes, 240 V maximum.” For models with suffix N or L.

Warning: “Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes, 480 V maximum.” For models with suffix H.

Warning: “Hot surface—risk of burn.”

Warning: “Install device in pollution degree 2 environment.”

Warning: “Maximum Surrounding Air Temperature 50°C.”

Warning: “Risk of electric shock—capacitor discharge time is at least 5 minutes.”

Warning: “Solid state motor overload protection is provided in each model.”

Warning: “Tightening torque and wire range for field wiring terminals are marked adjacent to the terminal or on the wiring diagram.”

1

Image 3
Contents SJ2002 Series Inverter Quick Reference Guide Page UL Cautions, Warnings, and Instructions Wiring Warnings for Electrical Practices and Wire SizesAWG Terminal Tightening Torque and Wire SizeFuse and Circuit Breaker Sizes Wire ConnectorsMotor Overload Protection HFU2 Power Circuit TerminalsDescription Ratings and Notes Control Circuit TerminalsAL2 SJ200 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Program ModeStep Description Via Keypad Via Logic Terminals Powerup TestBasic Error Codes Error CodesE60 Error Trip ConditionsRestoring Factory Default Settings Group Monitoring Functions Parameter TablesTrip History and Inverter Status Monitor ModeGroup Standard Functions Group Main Profile ParametersFunc Default Set Name / Description Value Code Gain setting AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C052 PID FBV function high limit C082 OI input span calibration Group Expansion Card Functions Group Motor Constants FunctionsIntelligent Input Terminal Listing Symbol Code Input Terminal NameIntelligent Output Terminal Listing Analog Input ConfigurationOption Function Name Description Corresponding Code Analog Output Function Listing