Hitachi SJ2002 manual AVR voltage select

Page 23

Func.

 

 

Default

Set

Name / Description

Value

Code

Value

 

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

A081

AVR function select

 

00

 

 

• 00 AVR enabled

• 01 AVR disabled

 

 

 

• 02 AVR enabled except during decel

 

 

 

 

 

 

 

A082

AVR voltage select

 

230 / 230

 

 

 

 

400 / 460

 

 

 

 

 

A092/

Acceleration (2) time setting

15.0

 

A292

 

 

 

 

 

 

 

 

A093/

Deceleration (2) time setting

15.0

 

A293

 

 

 

 

 

 

 

 

A094/

Select method to switch to Acc2/Dec2 profile

00

 

A294

• 00 2CH input from terminal

 

 

 

• 01 transition frequency

 

 

 

 

 

 

A095/

Acc1 to Acc2 frequency transition point

0.0

 

A295

 

 

 

 

 

 

 

 

A096/

Dec1 to Dec2 frequency transition point

0.0

 

A296

 

 

 

 

 

 

 

 

A097

Acceleration curve selection

00

 

 

• 00 Linear

• 01 S-curve

 

 

 

 

 

 

A098

Deceleration curve selection

00

 

 

• 00 Linear

• 01 S-curve

 

 

 

 

 

 

A101

[OI]–[L] input active range start frequency

0.0

 

 

 

 

 

A102

[OI]–[L] input active range end frequency

0.0

 

 

 

 

 

A103

[OI]–[L] input active range start current

0.0

 

 

 

 

 

A104

[OI]–[L] input active range end current

100.

 

 

 

 

 

A105

[OI]–[L] input start frequency enable

01

 

 

 

 

 

A141

A input select for calculate function

02

 

 

• 00 Digital operator

 

 

 

 

• 01 Keypad potentiometer

 

 

 

• 02 [O] input

 

 

 

 

• 03 [OI] input

 

 

 

 

• 04 Network variable

 

 

 

 

 

 

A142

B input select for calculate function

03

 

 

• 00 Digital operator

 

 

 

 

• 01 Keypad potentiometer

 

 

 

• 02 [O] input

 

 

 

 

• 03 [OI] input

 

 

 

 

• 04 Network variable

 

 

 

 

 

 

 

A143

Calculation symbol

 

00

 

 

• 00 ADD (A input + B input)

 

 

 

• 01 SUB (A input – B input)

 

 

 

• 02 MUL (A input x B input)

 

 

 

 

 

 

 

A145

ADD frequency

 

0.0

 

 

 

 

 

 

21

Image 23
Contents SJ2002 Series Inverter Quick Reference Guide Page UL Cautions, Warnings, and Instructions Wiring Warnings for Electrical Practices and Wire SizesAWG Terminal Tightening Torque and Wire SizeFuse and Circuit Breaker Sizes Wire ConnectorsMotor Overload Protection HFU2 Power Circuit TerminalsDescription Ratings and Notes Control Circuit TerminalsAL2 SJ200 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Program ModeStep Description Via Keypad Via Logic Terminals Powerup TestBasic Error Codes Error CodesE60 Error Trip ConditionsRestoring Factory Default Settings Group Monitoring Functions Parameter TablesTrip History and Inverter Status Monitor ModeGroup Standard Functions Group Main Profile ParametersFunc Default Set Name / Description Value Code Gain setting AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C052 PID FBV function high limit C082 OI input span calibration Group Expansion Card Functions Group Motor Constants FunctionsIntelligent Input Terminal Listing Symbol Code Input Terminal NameIntelligent Output Terminal Listing Analog Input ConfigurationOption Function Name Description Corresponding Code Analog Output Function Listing