Hitachi SJ2002 manual Group Main Profile Parameters, Group Standard Functions

Page 20

Parameter tables for user-settable functions follow these conventions:

Some parameters have 2nd motor equivalents, indicated by the x2xx parameter codes in the left-most column.

Some parameters specify an option code. Where applicable, the options codes will be in a bulleted list in the Name/Description column.

The default values apply to all models unless otherwise noted for each parameter... –FE(F) (Europe) / – FU (U.S.)

Some parameters cannot be edited during Run Mode, and certain Software Lock settings (B031) can prohibit all edits. If in doubt, place the inverter in Stop Mode or consult the inverter manual for details.

“F” Group: Main Profile Parameters

Func.

 

Name / Description

Default

Set

Code

 

Value

Value

 

 

 

 

 

 

 

 

 

 

F001

Output frequency setting

0.0

 

 

 

 

 

F002

Acceleration (1) time setting

10.0

 

 

 

 

 

F202

Acceleration (1) time setting, 2nd motor

10.0

 

 

 

 

 

F003

Deceleration (1) time setting

10.0

 

 

 

 

 

F203

Deceleration (1) time setting, 2nd motor

10.0

 

 

 

 

 

F004

Keypad Run key routing

00

 

 

• 00 Forward

• 01 Reverse

 

 

 

 

 

 

 

“A” Group: Standard Functions

Func.

 

Default

Set

Name / Description

Value

Code

Value

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

 

A001/

Frequency source setting

01 / 00

 

A201

• 00 Keypad potentiometer

 

 

 

• 01 Control terminal

 

 

 

• 02 Function F001 setting

 

 

 

• 03 ModBus network input

 

 

 

• 10 Calculate function input

 

 

 

 

 

 

A002/

Run command source setting

01 / 02

 

A202

• 01 Input terminal FW or RV (assignable)

 

 

 

• 02 Run key on keypad, or digital operator

 

 

 

• 03 ModBus network input

 

 

 

 

 

 

18

Image 20
Contents SJ2002 Series Inverter Quick Reference Guide Page Wiring Warnings for Electrical Practices and Wire Sizes UL Cautions, Warnings, and InstructionsTerminal Tightening Torque and Wire Size AWGWire Connectors Fuse and Circuit Breaker SizesMotor Overload Protection Power Circuit Terminals HFU2Control Circuit Terminals Description Ratings and NotesAL2 Basic Wiring Diagram SJ200Inverter Keypad Operation HitachiPage Program Mode Keypad Navigation MapPowerup Test Step Description Via Keypad Via Logic TerminalsError Codes Basic Error CodesError Trip Conditions E60 Restoring Factory Default Settings Parameter Tables Group Monitoring FunctionsMonitor Mode Trip History and Inverter StatusGroup Main Profile Parameters Group Standard FunctionsFunc Default Set Name / Description Value Code Gain setting AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C052 PID FBV function high limit C082 OI input span calibration Group Motor Constants Functions Group Expansion Card FunctionsSymbol Code Input Terminal Name Intelligent Input Terminal ListingAnalog Input Configuration Intelligent Output Terminal ListingAnalog Output Function Listing Option Function Name Description Corresponding Code