Hitachi SJ2002 manual C082 OI input span calibration

Page 28

Func.

 

 

 

 

Default

Set

Name / Description

Value

Code

Value

 

 

 

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C076

Communication error select

 

02

 

 

• 00 Trip (error code E60)

 

 

 

 

• 01 Decelerate to stop and trip (error code E60)

 

 

 

• 02 Disable

 

 

 

 

 

 

• 03 Free run stop (coasting)

 

 

 

• 04 Decelerate to a stop

 

 

 

 

 

 

 

C077

Communication error time-out

0.00

 

 

 

 

 

 

C078

Communication wait time

 

0.

 

 

 

 

 

 

C081

O input span calibration

 

100.0

 

 

 

 

 

 

C082

OI input span calibration

 

100.0

 

 

 

 

 

 

C085

Thermistor input tuning

 

100.0

 

 

 

 

 

 

C086

[AM] terminal offset tuning

 

0.0

 

 

 

 

 

 

 

 

C091

Debug mode enable

 

 

 

00

 

 

• 00 Display

• 01 No display

 

 

 

 

 

 

C101

Up/Down memory mode selection

00

 

 

• 00 Clear last frequency (return to default

 

 

 

frequency F001)

 

 

 

 

 

 

• 01 Keep last frequency adjusted by UP/DWN

 

 

 

 

 

 

 

 

 

C102

Reset selection

 

 

 

00

 

 

• 00 Cancel trip state at input signal ON transi-

 

 

 

tion, stops inverter if in Run Mode

 

 

 

• 01 Cancel trip state at signal OFF transition,

 

 

 

stops inverter if in Run Mode

 

 

 

• 02 Cancel trip state at input signal ON transi-

 

 

 

tion, no effect if in Run Mode

 

 

 

 

 

 

 

C141

Input A select for logic

 

Nine option codes

00

 

 

output

 

 

available

 

 

 

 

 

 

(LOG excluded),

 

 

C142

Input B select for logic

 

01

 

 

see page 29

 

 

output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C143

Logic function select

 

 

 

00

 

 

• 00 [LOG] = A AND B

 

 

 

 

• 01 [LOG] = A OR B

 

 

 

 

• 02 [LOG] = A XOR B

 

 

 

 

 

 

 

 

C144

Terminal [11] ON delay

 

0.0

 

 

 

 

 

 

C145

Terminal [11] OFF delay

 

0.0

 

 

 

 

 

 

C146

Terminal [12] ON delay

 

0.0

 

 

 

 

 

 

C147

Terminal [12] OFF delay

 

0.0

 

 

 

 

 

 

C148

Output relay ON delay

 

0.0

 

 

 

 

 

 

C149

Output relay OFF delay

 

0.0

 

 

 

 

 

 

 

 

26

Image 28
Contents SJ2002 Series Inverter Quick Reference Guide Page Wiring Warnings for Electrical Practices and Wire Sizes UL Cautions, Warnings, and InstructionsTerminal Tightening Torque and Wire Size AWGWire Connectors Fuse and Circuit Breaker SizesMotor Overload Protection Power Circuit Terminals HFU2Control Circuit Terminals Description Ratings and NotesAL2 Basic Wiring Diagram SJ200Inverter Keypad Operation HitachiPage Program Mode Keypad Navigation MapPowerup Test Step Description Via Keypad Via Logic TerminalsError Codes Basic Error CodesError Trip Conditions E60Restoring Factory Default Settings Parameter Tables Group Monitoring FunctionsMonitor Mode Trip History and Inverter StatusGroup Main Profile Parameters Group Standard FunctionsFunc Default Set Name / Description Value Code Gain setting AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C052 PID FBV function high limit C082 OI input span calibration Group Motor Constants Functions Group Expansion Card FunctionsSymbol Code Input Terminal Name Intelligent Input Terminal ListingAnalog Input Configuration Intelligent Output Terminal ListingAnalog Output Function Listing Option Function Name Description Corresponding Code