Hitachi SJ2002 manual Group Motor Constants Functions, Group Expansion Card Functions

Page 29

“H” Group: Motor Constants Functions

Func.

 

 

Default

Set

Name / Description

Value

Code

Value

 

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

H003/

Motor capacity

 

Factory set

 

H203

 

 

 

 

 

 

 

 

 

H004/

Motor poles setting

 

4

 

H204

• 2 poles

• 4 poles

 

 

 

• 6 poles

• 8 poles

 

 

 

 

 

 

H006/

Motor stabilization constant

100

 

H206

 

 

 

 

 

 

 

 

 

H007/

Motor voltage select

 

Factory set

 

H207

 

 

 

 

 

 

 

 

“P” Group: Expansion Card Functions

 

 

 

 

 

 

 

Func.

 

 

Default

Set

Name / Description

Value

Code

Value

 

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

P044

Network comm watchdog timer

1.00

 

 

 

 

 

P045

Inverter action on network comm error

01

 

 

• Trip (Error E70)

• Decel, stop, and trip

 

 

 

• Hold last speed

• Free run stop

 

 

 

• Decelerate and stop

 

 

 

 

 

 

 

P046

Polled I/O output instance number

21

 

 

• 20

• 21

 

 

 

• 100

 

 

 

 

 

 

 

P047

Polled I/O input instance number

71

 

 

• 70

• 71

 

 

 

• 101

 

 

 

 

 

 

 

P048

Inverter action on network idle mode

01

 

 

• Trip (Error E70)

• Decel, stop, and trip

 

 

 

• Hold last speed

• Free run stop

 

 

 

• Decelerate and stop

 

 

 

 

 

 

 

P049

Network motor poles setting for RMP

0

 

 

 

 

 

 

Note: The “P” Group parameters do not appear in the parameter list shown on the keypad display unless the expansion card is installed on the inverter.

27

Image 29
Contents SJ2002 Series Inverter Quick Reference Guide Page UL Cautions, Warnings, and Instructions Wiring Warnings for Electrical Practices and Wire SizesAWG Terminal Tightening Torque and Wire SizeFuse and Circuit Breaker Sizes Wire ConnectorsMotor Overload Protection HFU2 Power Circuit TerminalsDescription Ratings and Notes Control Circuit TerminalsAL2 SJ200 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Program ModeStep Description Via Keypad Via Logic Terminals Powerup TestBasic Error Codes Error CodesE60 Error Trip ConditionsRestoring Factory Default Settings Group Monitoring Functions Parameter TablesTrip History and Inverter Status Monitor ModeGroup Standard Functions Group Main Profile ParametersFunc Default Set Name / Description Value Code Gain setting AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C052 PID FBV function high limit C082 OI input span calibration Group Expansion Card Functions Group Motor Constants FunctionsIntelligent Input Terminal Listing Symbol Code Input Terminal NameIntelligent Output Terminal Listing Analog Input ConfigurationOption Function Name Description Corresponding Code Analog Output Function Listing