MOUNTING

All OutBack FX’s can be mounted in any position. Better performance will be achieved if it is mounted in a location which allows for air to circulate around the exterior of the casting. Locating the FX in a cool location will improve the operation and ensure the highest efficiency and power capacity.

The following drawing provides the mounting and overall dimensions of the FX with the FXA kit (DCC + ACA + DCA) attached. The first dimension is inches and the second value in parenthesis is the metric value in millimeters.

ACA

DCC

DCA

Depth out from Wall / Height up from Shelf: 11.87 inches (301 mm) / 12.87 INCHES (327mm) with Turbo installed

For installations where the FX may be exposed to water spray, either mount the FX with the base down (shelf mounting) or with the AC wiring compartment at the bottom (wall mounting). This will minimize the entry of water into the AC wiring compartment.

The FX-ACA can be used to add an AC outlet and one or two of OutBack’s AC rated OBDC circuit breakers (up to 70 amps max). When these items are added to the FX, it should only be used in an area that is protected from rain.

AC Wiring Compartment (with Outlet or Circuit Breaker Knock-Outs)

Side view of FX with FXA kit attached. The Turbo Kit adds 1” (25mm) additional height to achieve a total height of 12.87” (327mm)

Installation & Programming Manual

FX & VFX “E” Series Inverter/Charger System

Copyright 2003  OutBack Power Systems, Inc.

 

900-0027-2

19009 62nd Ave NE, Arlington WA 98223 USA

Page 10

Rev 7.1

06/08/06

Tel 360 435 6030 Fax 360 435 6019

Image 10
Contents Installation and Programming Manual Export FX and VFX Inverter/Charger900-0027-2 Table of Contents Stacking Instructions Wire Sizes Warranty RegistrationMate Screens EU Declaration of Conformity Declaration of ConformityInstallation Guidelines Important Safety InstructionsPersonal Precautions While Working with Batteries General PrecautionsAdditional Notices Ratings Maximum AC Output Current Maximum Continuous Output PowerAC Input Frequency Range Maximum Overcurrent Protection AmpacityMounting ACA DCC DCAPsac Psdc PS2AC PS2DC Complete Outback Integrated SystemsAC Wiring Connections Inverter ON/OFF Indicators / Control WiringBattery Temp Remote Temperature Sensor RTS Auxiliary Output AUX + / AUXBattery Terminal Covers Battery FX CablingDC Battery Terminals Equipment Ground TerminalsFX-ACA AC Conduit Adapter FX AccessoriesFXA Accessory KIT FX-DCA DC Conduit AdapterHUB Communication Manager Slave MasterTurbo KIT Information FX System Configuration Single FX System Single FX SystemFX System Configuration Paralleled Dual FX System Paralleled Dual FX SystemFX System Configuration Paralleled Quad FX System Paralleled Quad FX SystemPhase FX System FX System Configuration 3 Phase FX SystemSTART-UP & Operation Battery Charging Instructions Battery Charging Set PointsStack Phase OutBack & 3-phase Stacking MethodsStacking Procedure Stacking InstructionsPower Save Level Master Adjust only Power Save Level Slave Adjust onlyPhase Stacked System 3 FX’S only Stacked System Using OUTBACK’S Parallel StackingSystem Examples Automatic Generator Start Instructions Mate System Controller and Display OutBack Mate System ControllersOutBack Mate Mate Buttons SETUP/FX/INPUT---P00Menu Structure GENGEN TOP Setup Main‘SOFT’ Keys Down Grid GENInverter Control Inverter ControlOFF Srch on OK AC Input Control Mate Menu MAP Mate Menu MAP Mate Screens SUM Status Setup ADVSummary Screen ExamplesFX MX Status ScreensModes Menu ModesDown UP Meter MenuDown MeterBattery Menu BattError Menu ErrorWarn WarnDisconnect Menu DisconPG3 Sell MenuSell Srch Input Setup ScreensSearch Menu SrchSrch Input Main INC DEC Port SETUP/FX/INPUTInput Menu InputPG2 Password Code 1 4Advanced Screens PG4INV Inverter MenuDownmore Charger Menu Down INCGrid Grid MenuPG1 GEN PG3 ADV/FX/GRIDPG1 Grid Generator MenuOFF Port PG2 AUX Stack PG4 Auxiliary MenuADV INV Chgr PG2 Down INC PortDEC Port Stack Stacking MenuPG2 AUX ADV/FX/STACKSell Calibration Menu END of Advanced Menu SystemCAL Wire Sizes AWGTwo Year Limited Warranty Warranty900-0027-2 Extended Warranty Application Registration