BATTERY CHARGING INSTRUCTIONS

Keeping your battery bank healthy is very important. Although a battery bank may last for over 10 years if properly cared for, it can also be ruined in less than a month if neglected. Since the batteries are the lifeblood of the system and represent a large percentage of the cost to the consumer, keeping them healthy is necessary.

Battery Charging Set Points

In order to make sure the batteries stay healthy, they must never be discharged too much and should be regularly charged back to near-full capacity. (Full capacity is only achieved by equalizing the batteries. Check with the battery manufacturer to see how often your batteries should be equalized.) It is necessary for the system operator to gather some information from the battery manufacturer. This information should include the following…

The ‘Absorb’ Voltage

The ‘Float’ Voltage

The ‘Equalize’ Voltage

The Recommended Depth of Discharge (DOD) of the batteries

These ‘Absorb’, ‘Float’, and ‘Equalize’ voltage set points should be programmed into the FX through the MATE (see page 48).

Programming the ‘Absorb Time Limit’ is tougher and requires some experimenting and calculations. We will be assuming that the generator or the utility grid will be the only device charging the batteries. A general rule for knowing when the batteries are fully charged and the absorption cycle can be stopped is the formula C/40. C is your battery bank capacity which you divide by 40. So, take the total amp-hour capacity of the batteries and divide it by 40. The resulting number is the ‘DC current’ at which the batteries are fully charged. Write this number down. Next, divide the ‘DC Current’ by the number of FX’s that will be charging the batteries. This is your new ‘DC Current’. Next, do a calculation to find the ‘AC Current’ needed to produce this ‘DC Current’ by following this formula…

AC Current =

(DC Current) x (Absorb Voltage)

(Round this number down to the nearest integer)

(AC Input Voltage)

 

 

Next, through the MATE, follow the path MAIN / ADV / (any button) / PASSWORD (141) / FX / CHGR / DOWN / DOWN. The screen should show “Absorb Time Limit’. Set this value arbitrarily high, say 4 hours.

To set the correct time in the ‘Absorb Time Limit’ the user must perform the following experiment on the system. First, the user should discharge the batteries to the recommended depth of discharge and then connect the AC input to all FX’s charging the batteries and let the FX’s charge the batteries. The user must carefully watch for when the FX’s reaches the ‘Absorb Setpoint’ voltage and record the current time. Next, the user should watch the ‘Charger Current’ screen found by following the path MAIN / STATUS / FX / METER and pressing DOWN four times. When the value on the screen matches the ‘AC Current’ value that was calculated, then again record the current time. The appropriate ‘Absorb Time Limit’ for the system is the difference between these two times (round this value up if necessary). Follow the path MAIN / ADV / (any button) / PASSWORD (141) / FX / CHGR / DOWN / DOWN to get to the ‘Absorb Time Limit’ screen and use the INC or DEC buttons to adjust the value. If there is another source (solar, wind, hydro, etc.) charging the batteries, then the ‘Absorb Time Limit’ can be reduced. It is up to the user to decide or the System Design Specialist to set the ‘Absorb Time Limit’ if this is the case.

Battery Charging Operation

The FX’s battery charger includes five stages. The first stage, BULK, raises the battery voltage to the ‘Absorb Setpoint’. The second stage, ABSORB, sustains the battery voltage at the ‘Absorb Setpoint’ for the ‘Absorb Time Limit’. The charger then goes into the third stage, SILENT mode (no charging), until the battery voltage drops to the ‘Float Setpoint’. This fourth stage, FLOAT, sustains this battery voltage for the ‘Float Time Period’. The charger then goes into ‘Silent’ mode again until the battery voltage drops to the ‘Refloat Setpoint’. This fifth stage, REFLOAT, will start another FLOAT charge. There are additional screens for “Equalize Setpoint’ and ‘Equalize Time Period’. An equalize charge must be manually started and should be performed once every three months. The time limits that it spends in the various stages are adjustable to provide control and maximize the performance of the battery charger and battery system.

Copyright 2003  OutBack Power Systems, Inc.

FX & VFX “E” Series Inverter/Charger System

Installation & Programming Manual

19009 62nd Ave NE, Arlington WA 98223 USA

900-0027-2

 

Tel 360 435 6030 Fax 360 435 6019

Rev 7.1 06/08/06

Page 23

Image 23
Contents Export FX and VFX Inverter/Charger Installation and Programming Manual900-0027-2 Table of Contents Mate Screens Wire Sizes Warranty RegistrationStacking Instructions Declaration of Conformity EU Declaration of ConformityImportant Safety Instructions Installation GuidelinesAdditional Notices General PrecautionsPersonal Precautions While Working with Batteries Ratings Maximum Overcurrent Protection Ampacity Maximum Continuous Output PowerAC Input Frequency Range Maximum AC Output CurrentACA DCC DCA MountingComplete Outback Integrated Systems Psac Psdc PS2AC PS2DCAC Wiring Connections Auxiliary Output AUX + / AUX Indicators / Control WiringBattery Temp Remote Temperature Sensor RTS Inverter ON/OFFEquipment Ground Terminals Battery FX CablingDC Battery Terminals Battery Terminal CoversFX-DCA DC Conduit Adapter FX AccessoriesFXA Accessory KIT FX-ACA AC Conduit AdapterSlave Master HUB Communication ManagerTurbo KIT Information Single FX System FX System Configuration Single FX SystemParalleled Dual FX System FX System Configuration Paralleled Dual FX SystemParalleled Quad FX System FX System Configuration Paralleled Quad FX SystemFX System Configuration 3 Phase FX System Phase FX SystemSTART-UP & Operation Battery Charging Set Points Battery Charging InstructionsStacking Instructions OutBack & 3-phase Stacking MethodsStacking Procedure Stack PhasePower Save Level Slave Adjust only Power Save Level Master Adjust onlySystem Examples Stacked System Using OUTBACK’S Parallel StackingPhase Stacked System 3 FX’S only Automatic Generator Start Instructions OutBack Mate System Controllers Mate System Controller and DisplayOutBack Mate GEN SETUP/FX/INPUT---P00Menu Structure Mate ButtonsDown Grid GEN TOP Setup Main‘SOFT’ Keys GENOFF Srch on OK Inverter ControlInverter Control AC Input Control Mate Menu MAP Mate Menu MAP Examples SUM Status Setup ADVSummary Screen Mate ScreensModes Status ScreensModes Menu FX MXMeter Meter MenuDown Down UPBatt Battery MenuError Error MenuWarn WarnDiscon Disconnect MenuSell Sell MenuPG3 Srch Setup ScreensSearch Menu Srch InputInput INC DEC Port SETUP/FX/INPUTInput Menu Srch Input MainPG4 Password Code 1 4Advanced Screens PG2Downmore Inverter MenuINV Down INC Charger MenuGEN PG3 ADV/FX/GRID Grid MenuPG1 GridOFF Port Generator MenuPG1 Grid Down INC Port Auxiliary MenuADV INV Chgr PG2 PG2 AUX Stack PG4DEC Port ADV/FX/STACK Stacking MenuPG2 AUX StackSell CAL END of Advanced Menu SystemCalibration Menu AWG Wire SizesWarranty Two Year Limited Warranty900-0027-2 Registration Extended Warranty Application