Outback Power Systems VFX3024E, VFX3048E, VFX2612E, FX2024ET, FX2348ET, FX2012ET manual Sell

Page 54

MATE SCREENS

SELL MENU

The SELL section is used to set the functions that control the process of selling power back to the utility grid. This menu is only operational for Grid-Tie FX’s and is not operational with “Export” FX’s at this time. These functions include setting the voltage at which the FX sells back to the utility grid, setting the window in which the Grid-Tie function operates, and to enable or disable the Grid-Tie function. The default values enable the Grid-Tie FX to sell back to the utility grid after the FX has completed a charge cycle. To disable this charge cycle, press the <AC IN> “hot” button four times, press <BULK>, press <STOP> and then press <OK>. The FX waits 5 minutes after it has accepted the utility grid as an AC source and must be above the “sell RE volts” (found in this menu) to start selling.

ADV/FX/PAGE1--------

choose category:

ADV INV CHGR PG2

ADV/FX/PAGE2--------

choose category:

PG1 GRID GEN PG3

ADV/FX/PAGE3--------

choose category:

 

PG2

AUX

STACK

PG4

 

 

 

 

 

ADV/FX/PAGE4--------

 

choose category:

 

 

PG3

SELL

CAL

MAIN

 

 

 

 

 

 

 

 

 

 

 

 

 

ADV/FX/SELL------

P00

 

sell re

12.8vdc

 

volts

 

 

 

DOWN

INC

DEC

PORT

ADV/FX/SELL------P00

grid tie

IEEE

window

 

DOWN

IEEE USER PORT

 

 

ADV/FX/SELL

------P00

grid tie

GridTie

authority

 

DOWN

INC

DEC PORT

ADV/FX/SELL------

selling setup completed

TOP ADV MAIN

Once the password has been correctly entered, the ADV - CHOOSE CATEGORY: screen is displayed. Selecting <PG2> shows a second screen of categories.

Selecting <PG3> shows a third screen of categories.

Selecting <PG4> shows a fourth screen of categories.

Selecting <SELL> allows adjustment of the Grid-tie and selling set points and operation.

The SELL RE VOLTS (RE = Renewable Energy) screen allows the user to set the voltage at which they would like to sell battery power back to the utility grid. If the battery voltage is above the voltage shown on this screen and the FX isn’t charging then the FX will sell power back to the utility grid. This setting has a range between 10.0 vdc and 15.0 vdc in 0.1vdc increments.

The GRID TIE WINDOW screen controls the voltage and frequency windows that the grid-tie function operates in. If the FX repeatedly disconnects from the utility grid this value may need to be changed. This function should not, I repeat, should not be changed without consulting OutBack Power Systems first.

The GRID TIE AUTHORITY screen allows the user to turn on or off the selling function of the FX. When the screen displays “GridTie” (default), the FX will sell power under the correct conditions. Pressing DEC will change “GridTie” to “No Sell” and the selling function will be disabled.

Pressing INC will change the display back from “No Sell” to “GridTie”.

Selecting TOP returns the user to the top of the ADV/FX/SELL menu section. Selecting ADV returns you to the advanced screen to allow selection of another product connected to the MATE. Selecting MAIN returns the display to the MAIN screen.

Installation & Programming Manual

FX & VFX “E” Series Inverter/Charger System

Copyright 2003  OutBack Power Systems, Inc.

 

900-0027-2

19009 62nd Ave NE, Arlington WA 98223 USA

Page 54

Rev 7.1

06/08/06

Tel 360 435 6030 Fax 360 435 6019

Image 54
Contents Installation and Programming Manual Export FX and VFX Inverter/Charger900-0027-2 Table of Contents Wire Sizes Warranty Registration Stacking InstructionsMate Screens EU Declaration of Conformity Declaration of ConformityInstallation Guidelines Important Safety InstructionsGeneral Precautions Personal Precautions While Working with BatteriesAdditional Notices Ratings Maximum AC Output Current Maximum Continuous Output PowerAC Input Frequency Range Maximum Overcurrent Protection AmpacityMounting ACA DCC DCAPsac Psdc PS2AC PS2DC Complete Outback Integrated SystemsAC Wiring Connections Inverter ON/OFF Indicators / Control WiringBattery Temp Remote Temperature Sensor RTS Auxiliary Output AUX + / AUXBattery Terminal Covers Battery FX CablingDC Battery Terminals Equipment Ground TerminalsFX-ACA AC Conduit Adapter FX AccessoriesFXA Accessory KIT FX-DCA DC Conduit AdapterHUB Communication Manager Slave MasterTurbo KIT Information FX System Configuration Single FX System Single FX SystemFX System Configuration Paralleled Dual FX System Paralleled Dual FX SystemFX System Configuration Paralleled Quad FX System Paralleled Quad FX SystemPhase FX System FX System Configuration 3 Phase FX SystemSTART-UP & Operation Battery Charging Instructions Battery Charging Set PointsStack Phase OutBack & 3-phase Stacking MethodsStacking Procedure Stacking InstructionsPower Save Level Master Adjust only Power Save Level Slave Adjust onlyStacked System Using OUTBACK’S Parallel Stacking Phase Stacked System 3 FX’S onlySystem Examples Automatic Generator Start Instructions Mate System Controller and Display OutBack Mate System ControllersOutBack Mate Mate Buttons SETUP/FX/INPUT---P00Menu Structure GENGEN TOP Setup Main‘SOFT’ Keys Down Grid GENInverter Control Inverter ControlOFF Srch on OK AC Input Control Mate Menu MAP Mate Menu MAP Mate Screens SUM Status Setup ADVSummary Screen ExamplesFX MX Status ScreensModes Menu ModesDown UP Meter MenuDown MeterBattery Menu BattError Menu ErrorWarn WarnDisconnect Menu DisconSell Menu PG3Sell Srch Input Setup ScreensSearch Menu SrchSrch Input Main INC DEC Port SETUP/FX/INPUTInput Menu InputPG2 Password Code 1 4Advanced Screens PG4Inverter Menu INVDownmore Charger Menu Down INCGrid Grid MenuPG1 GEN PG3 ADV/FX/GRIDGenerator Menu PG1 GridOFF Port PG2 AUX Stack PG4 Auxiliary MenuADV INV Chgr PG2 Down INC PortDEC Port Stack Stacking MenuPG2 AUX ADV/FX/STACKSell END of Advanced Menu System Calibration MenuCAL Wire Sizes AWGTwo Year Limited Warranty Warranty900-0027-2 Extended Warranty Application Registration