MATE SCREENS
SELL MENU
The SELL section of the STATUS menu has only one screen. This screen gives a number that refers to a reason the FX would stop selling. OutBack Power Systems technicians use this number to quickly understand what the FX thinks is happening. The system user should not be concerned about this number unless they are experiencing many unknown grid disconnects and they need troubleshooting help. This screen is only operational with
| ||
| 6:54:42P |
|
SUM STATUS SETUP ADV | ||
↓ |
| |
choose product: |
| |
FX | MX |
|
↓ |
|
|
choose category: |
| |
MODES METER BATT PG2 | ||
|
| ↓ |
choose category: |
| |
PG1 ERROR WARN | PG3 | |
|
| ↓ |
choose category: |
| |
PG2 DISCON SELL MAIN | ||
| ↓ |
|
stop sell | 14 | |
reason |
|
|
STATUS |
| PORT |
The MAIN screen is where the menu system starts. The four words in the bottom line of the display correspond to the four buttons located below the display. The word in BOLD on the bottom line indicates the selection used to advance the display to the next screen. Pressing the left two buttons simultaneously from anywhere in the menu will return you to this screen.
Allows selection of the product type:
<FX> | FX inverter/charger system |
MX | MX60 PV MPPT charge controller |
MODES | Status and allows adjustment of Inverter, AC input, Charger, Aux, and EQ |
METER | Provides the AC voltages and currents of the FX |
BATT | Provides the battery voltage and charger set points and timers |
<PG2> | Displays additional sections – ERRORS, WARNINGS and PG3 |
PG1 | Returns to page 1 of the STATUS section |
ERROR | Displays the different causes for errors and qualifies each cause with a Yes or No |
WARN | Displays the different causes for warnings and qualifies each with a Yes or No |
<PG3> | Displays additional sections – reason for last DISCONNECT and SELL |
PG2 | Displays additional sections – ERRORS, WARNINGS and PG3 |
DISCON | Displays the reason that the FX last disconnected from the AC source |
<SELL> | Displays the code related to the reason for the last disconnection while selling |
MAIN | Returns the user to the MAIN menu |
The STOP SELL REASON displays a numerical value that indicates a reason that the FX stopped selling to the utility grid. It could indicate that the utility grid’s voltage or frequency is out of the acceptable ranges or that the utility grid failed altogether. This screen is used for troubleshooting by OutBack Power Systems technicians. Selecting STATUS returns the user to the beginning of the STATUS menu. Selecting PORT selects the next FX on the HUB.
Copyright 2003 OutBack Power Systems, Inc. | FX & VFX “E” Series Inverter/Charger System | Installation & Programming Manual |
19009 62nd Ave NE, Arlington WA 98223 USA |
|
|
Tel 360 435 6030 Fax 360 435 6019 | Rev 7.1 06/08/06 |
Page 43