Porter-Cable PCL180ID Charging Procedure, Charger Diagnostics, BAD Battery, HOT/COLD Pack Delay

Page 8

90550107 PC1800ID, PC1200ID 4/1/09 9:33 AM Page 8

CHARGING PROCEDURE

PORTER-CABLEchargers are designed to charge PORTER-CABLEbattery packs in 30-60 minutes depending on the pack being charged.

1.Plug the charger into an appropriate outlet before inserting the battery pack.

2.Insert the battery pack into the charger. (Fig. B)

B

3. The LED will flash indicating that the battery is being charged.

4. The completion of charge is indicated by the LED remaining on continuously. The pack is fully charged and may be used at this time or left on the charger.

CHARGER DIAGNOSTICS

This charger is designed to detect certain problems that can arise with the battery packs or the power source. Problems are indicated by one LED flashing in different patterns.

BAD BATTERY

The charger can detect a weak or damaged battery. The LED flashes in the pattern indicated on the label. If you see this bad battery blink pattern, do not continue to charge the battery. Return it to a service center or a collection site for recycling.

HOT/COLD PACK DELAY

When the charger detects a battery that is excessively hot or excessively cold, it automatically starts a Hot/Cold Pack Delay, suspending charging until the battery has normalized. After this happens, the charger automatically switches to the Pack Charging mode. This feature ensures maximum battery life. The light flashes in the pattern indicated on the label.

PROBLEM POWER LINE

When the charger is used with some portable power sources such as generators or sources that convert DC to AC, the charger may temporarily suspend operation. The LED flashes in the pattern indicated on the label. This indicates that the power source is out of limits.

LEAVING THE BATTERY IN THE CHARGER

The charger and battery pack can be left connected with the LED glowing indefinitely. The charger will keep the battery pack fresh and fully charged. This charger features an automatic tune-up mode which equals or balances the individual cells in the battery pack to allow it to function at peak capacity. Battery packs should be tuned up weekly or whenever the battery no longer delivers the same amount of work. To use the automatic tune-up mode, place the battery pack in the charger and leave it for at least 8 hours.

IMPORTANT CHARGING NOTES

1.Longest life and best performance can be obtained if the battery pack is charged when the air temperature is between 65°F and 75°F (18°- 24°C). DO NOT charge the battery pack in an air temperature below +40°F (+4.5°C), or above +105°F (+40.5°C). This is important and will prevent serious damage to the battery pack.

2.The charger and battery pack may become warm to touch while charging. This is a normal condition, and does not indicate a problem. To facilitate the cooling of the battery pack after use, avoid placing the charger or battery pack in a warm environment such as in a metal shed, or an uninsulated trailer.

8

Image 8
Contents Advertencia Léase Este Catalog Numbers PCL180IDGeneral Power Tool Safety Warnings Specific Safety Rules Safety Guidelines Definitions Symbols Important Safety Instructions for Battery Chargers Battery CAP Information Storage RecommendationsCharging Procedure Charger DiagnosticsBAD Battery HOT/COLD Pack DelayInstalling and Removing the Battery Pack from the Tool Variable Speed Trigger Switch FIG. E Operating InstructionsFORWARD/REVERSE Control Button LED Worklight FIG. GTroubleshooting MaintenanceOn Board BIT Storage Specialnotes for USE with Lithium BatteriesAccessories Three Year Limited WarrantyReplacement Parts Service and Repairs Highway North Jackson, TN 888 DE Catalogue PCL180ID 90550107 PC1800ID, PC1200ID 4/1/09 933 AM 90550107 PC1800ID, PC1200ID 4/1/09 933 AM Consignes DE Sécurité Particulières Symboles Lignes Directrices EN Matière DE Sécurité DéfinitionsDescription Fonctionnelle Figure aLire Toutes LES Directives Procédure DE Charge Recommandations EN Matière DE RangementInformation Concernant LE Capuchon DU BLOC-PILE Fonctions DE Diagnostic DU Chargeur Pile EN Mauvais ÉtatFonction DE Suspension DU BLOC-PILES CHAUD/FROID Problème Avec LE SecteurBouton DE Commande Marche AVANT/MARCHE Arrière FIG. F FonctionnementInsertion ET Retrait DU BLOC-PILES DE L’OUTIL Détente À Vitesse Variable FIG. ELE Sceau Srprcmc Lampe DE Travail À DEL FIG. GMandrin À Blocage Rapide FIG. H EntretienAccessoires DépannageRemarques Spéciales SUR L’EMPLOIAVEC DES Pilesau Lithium Entretien ET RéparationRemplacement DES Étiquettes D’AVERTISSEMENT Garantie Limitée DE Trois ANSCatálogo N PCL180ID 90550107 PC1800ID, PC1200ID 4/1/09 933 AM 90550107 PC1800ID, PC1200ID 4/1/09 933 AM Normas Específicas DE Seguridad Pautas DE SEGURIDAD/DEFINICIONES SímbolosDescripción DE LAS Funciones Figura a LEA Todas LAS Instrucciones Procedimiento DE Carga Información Acerca DEL Protector DE LA BateríaRecomendaciones CON Respecto AL Almacenamiento Línea DE Potencia CON Problemas Diagnóstico DEL CargadorBatería EN MAL Estado Retraso POR Paquete CALIENTE/FRÍOInstrucciones DE Operación Interruptor Disparador DE Velocidad Variable Figura EPortabrocas DE Liberación Rápida Figura H Botón DE Control DE AVANCE/REVERSALUZ DE Trabajo DE LED Figura G Detección DE Problemas EL Sello RbrcNotas Especiales Paraeluso CON Baterías DE Litio MantenimientoAccesorios Garantía Limitada DE Tres AñosPiezas DE Repuesto Mantenimiento Y Reparaciones Pcmvc Pclmvc Pcxmvc Reemplazo DE LAS Etiquetas DE Advertencia