Bryant 569J Factory-installed options FIOPs, Efficient operation, Indoor-air quality IAQ features

Page 2

FEATURES AND BENEFITS (cont.)

569J

Factory-installed options (FIOPs)

Certified and pre-engineered factory-installed options (FIOPs) allow units to be installed in less time, thereby reducing installed cost. FIOPs include:

S low ambient controls which provide cooling operation down to -20_F (-29_C) ambient temperatures

S non-fused disconnect

S 115-v GFI (ground fault interrupter) convenience outlet, powered and non-powered available

S special coil coating coil protection S louvered hail guard

Efficient operation

These air cooled condensing units will provide EER’s up to 11.5 which meets ASHRAE 90.1 efficiency levels. The 569J dual compressor models provide two (2) stages of cooling for remarkable partial load performance.

This high efficiency will help reduce overall operating cost and energy consumption.

Controls for performance dependability

The 569J condensing units offer operating controls and components designed for performance dependability. The high efficiency hermetic scroll compressor is engineered for long life and durability. The compressors include vibration isolation for quiet operation. The high-pressure switch protects the entire refrigeration system from abnormally high operating pressures. A low-pressure switch protects the system from loss of charge. These units also include anti-short-cycling protection, which helps to protect the units against compressor failure.

All units include a crankcase heater to eliminate liquid slugging at start-up. Each unit comes standard with the Comfort Alertt control system. This provides:

S System Go LED indicator S Fault LED indicator

S Compressor fault LED indicator S Phase loss protection

S Phase reversal protection S Safety pressure indicator

SAnti-short cycle protection

The latest safety standards for 569J* units are assured through UL, Canada approvals.

Innovative Bryant 524J packaged air handlers are custom matched to 569J*condens- ing units

Information on matching 524J DX packaged air handler follows for convenience. See separate product data for more details. The 524J Series has excellent fan performance, efficient direct-expansion (DX) coils, a unique combination of indoor-air quality features, and is easy to install. Its versatility and state-of-the-art features

help to ensure economical performance of the split system both now and in the future.

Indoor-air quality (IAQ) features

The unique combination of IAQ features in the 524J Series air handlers help to ensure that only clean, fresh, conditioned air is delivered to the occupied space.

Direct-expansion (DX) 4 row cooling coils prevent the build-up of humidity in the room, even during part-load conditions.

Standard 2-in. (51mm) disposable filters remove dust and airborne particles from the occupied space for cleaner air.

The pitched, non-corroding drain pan can be adjusted for

aright-hand or left-hand connection to suit many applications and provide positive drainage and prevent standing condensate.

The accessory economizer can provide ventilation air to improve indoor-air quality by using demand control ventilation. When used in conjunction with Bryant Comfort System and CO2 sensors, the economizer admits fresh outdoor air to replace stale, recirculated indoor air.

Economy

The 524J Series packaged air handlers provide reduced installation expense and energy-efficient performance.

Quick installation is ensured by the multipoise design. Units can be installed in either the horizontal or vertical configuration without modifications. Fan motors and contactors are pre-wired and thermostatic expansion valves (TXVs) are factory-installed on all 524J models.

High efficiency, precision-balanced fans minimize air turbulence, surging, and unbalanced operation, cutting operation expenses.

The economizer accessory precisely controls the blend of outdoor air and room air to achieve comfort levels. When the outside air enthalpy is suitable, outside air dampers can fully open to provide “free” cooling without energizing mechanical cooling.

Rugged dependability

The 524J series units are made to last. The die-formed galvanized steel panels ensure structural integrity under all operating conditions. Galvanized steel fan housings are securely mounted to a die-formed galvanized steel fan deck.

Rugged pillow-block bearings (524J14) are securely fastened to the solid steel fan shaft with split collets and clamp locking devices. Smaller unit sizes have spider-type bearings.

2

Image 2
Contents Features / Benefits Product DataEfficient operation Factory-installed options FIOPsIndoor-air quality IAQ features Controls for performance dependabilityTable of Contents Model Number Nomenclature AHRI* Capacity Ratings Sound Power LEVELS, dBUnit Compressors Capacity Power EER Ieer Circuits Tons MBH Cooling NOM NET Cooling569J*07A Physical Data569J*07A 569J*08A 569J*12A 569J*14A 569J*16A 569J*12A 569J*14A 569J*16A569J*25D Dimensions Dimensions C101214 569J* Options and Accessories Options and Accessories569J* factory-installed options Condenser Coil Options524J field-installed accessories 569J* field-installed accessories524J factory-installed options 524J Options and AccessoriesOptions and Accessories 524J with Economizer UV-C Germicidal Lamps Operating sequences Selection ProcedureControls Typical Wiring Schematic Typical Wiring Schematic 569J*07A AIR Temperature Entering Condenser FPerformance Data 569J*08AAIR Temp ENT Condenser F 569J*12A569J*12D Dual Circuit 100 105 115 120569J*14A 569J*14D Dual Circuit105 115 125 569J*16A569J*16D Dual Circuit 569J*25A 569J*25D Dual Circuit569J*07A 524J*07 Combination Ratings2600 Cfm 569J*07A 524J*082250 Cfm 3375 Cfm 569J*08A 524J*082625 Cfm 3750 Cfm3500 569J*08A 524J*12Cfm 4000 Cfm5000 Cfm 569J*12A 524J*123500 Cfm 5700 Cfm 569J*12 A- 524J*144300 Cfm 569J*12D 524J*12 569J*12D 524J*14 5625 Cfm 569J*14A 524J*144375 Cfm 6250 Cfm6000 Cfm 569J*14A 524J*165300 Cfm EA wb 6800 Cfm569J*14D 524J*14 569J*14D 524J*16 5300 Cfm569J*16A 524J*16 8000 Cfm 569J*16A 524J*257000 Cfm 9000 Cfm569J*16D- 524J*16 569J*16D 524J*25 8000 Cfm EA wb9000 Cfm EA wb 569J*25A 524J*257000 Cfm EA wb 8750 Cfm 569J*25A- 524J*287500 Cfm 569J*25D- 524J*25 569J*25D- 524J*28 8750 Cfm EA wb569J*08A Cooling with Powered Convenience Outlet 569J*07A Cooling Without Powered Convenience Outlet569J*07A Cooling with Powered Convenience Outlet 569J*08A Cooling Without Powered Convenience Outlet569J*12D Cooling Without Powered Convenience Outlet 569J*12A Cooling Without Powered Convenience Outlet569J*12A Cooling with Powered Convenience Outlet 569J*12D Cooling with Powered Convenience Outlet569J*14D Cooling Without Powered Convenience Outlet 569J*14A Cooling Without Powered Convenience Outlet569J*14A Cooling with Powered Convenience Outlet 569J*14D Cooling with Powered Convenience Outlet569J*16A Cooling with Powered Convenience Outlet 569J*16A Cooling Without Powered Convenience Outlet569J*16D Cooling Without Powered Convenience Outlet 569J*16D Cooling with Powered Convenience Outlet569J*25A Cooling with Powered Convenience Outlet 569J*25A Cooling Without Powered Convenience Outlet569J*25D Cooling Without Powered Convenience Outlet 569J*25D Cooling with Powered Convenience OutletOperating limits Minimum OUTDOOR-AIR Operating TemperatureApplication Data Refrigerant piping569J* 07-14 Piping Recommendations SINGLE-CIRCUIT Unit 569J*16 569J 16-25 Piping Recommendations SINGLE-CIRCUIT UnitModel 569J*25569J 12-14 Piping Recommendations TWO-CIRCUIT Unit Model 569J*12569J 16-25 Piping Recommendations TWO-CIRCUIT Unit Typical Piping and Wiring Roof Installation and a Ceiling-Mounted Fan CoilRoof Installation and a Vertical Discharge Fan Coil Ground Level Installation and Vertical Discharge Fan Coil Dual Condensing Units and a Dual Circuit Fan Guide Specifications System Description569J 569J Catalog No. PDS569J---03