Woodstock W1673 Electrical Requirements, 110V Operation, Extension Cords, Grounding

Page 7

ELECTRICAL REQUIREMENTS

110V Operation

The Shop Fox® W1673 Bandsaw is prewired for 110 volt operation. The motor supplied with your new bandsaw is rated at 112 H.P. and will draw approximately 16 amps. When choosing an outlet for this machine, consider using one with a 20 amp circuit breaker or fuse. Keep in mind that a circuit being used by other machines or tools at the same time will add to the total load being applied to the circuit. Add up the load rat- ings of all machines on the circuit. If this num- ber exceeds the rating of the circuit breaker or fuse, use a different circuit.

This equipment must be grounded. Verify that any existing electrical outlet and circuit you intend to plug into is actually grounded. If it is not, it will be necessary to run a sep- arate 12 A.W.G. copper grounding wire from the outlet to a known ground. Under no cir- cumstances should the grounding pin from any three-pronged plug be removed or seri- ous injury may occur.

Extension Cords

When it is necessary to use an extension cord, use the following guidelines:

•Use cords rated for Hard Service •Never exceed a length of 100 feet •Use cords with 14 ga. wire or bigger •Insure cord has a ground wire and pin •Do not use cords in need of repair

Grounding

This machine must be grounded! See Figure 1B. The electrical cord supplied with the W1673 comes with a grounding pin. Do not remove it. If your outlet does not accommodate a ground pin, have it replaced by a qualified electrician or have an appropriate adapter installed. Please note: When using an adapter, the adapter must be grounded.

1A. Never remove the grounding pin!

Figure 1B. Typical 110V 3-prong plug and outlet.

6

Image 7
Contents Bandsaw Table Of Contents Introduction About Your NEW Bandsaw Woodstock Service and SupportMachine Specifications Warranty and ReturnsDisconnect machine when cleaning, adjusting or servicing Safety FirstKeep proper footing and balance at all times Additional Safety Instructions For BandsawsGrounding Electrical Requirements110V Operation Extension Cords220V Operation Unplug saw before changing blades Avoiding Potential InjuriesUse push blocks when necessary Contents Assembly InstructionsStand HardwareLifting tensioning handle Bandsaw BodyQuick-Connect Cord Mounting MotorMounting Dust Port Mounting TableTo mount the table Fence/Rails Rail placementLocation of Controls AdjustmentsSpeed Changes Diagram of speed optionsTo install the blade Install/Remove BladesTo remove the blade To tighten your blade by deflection To adjust blade tensionBlade Tension To tighten your blade by soundTracking To track the blade using center trackingRead the next section for coplanar tracking To check if your wheels are coplanar Wheel AlignmentLower wheel adjustment control Blade guide assemblies Blade GuidesGuide block position on blade To adjust the guide blocksTo square the table to the blade Table AdjustmentsTo make the miter gauge slot parallel with the blade Table AdjustmentsTo set the fence so it is parallel to the miter slot Fence AdjustmentsBlade Lead To adjust for blade lead with the fence only optionGeneral OperationsTest Run Crosscutting RippingTo perform ripping operations Resawing Cutting CurvesTo make curved cuts Stacked Cuts To resaw, follow this basic procedureTo make stacked cuts Blade Teeth Blade SelectionBlade Type Blade WidthLubrication MaintenanceMaintenance Notes Maintenance SchedulePage Closure Page Page Page XPB03 Adapter Warranty Card BOX BELLINGHAM, WA