RIDGID kt-190 General Safety Information, Work Area Safety, Electrical Safety, Personal Safety

Page 4

Model KT-190 and KT-200 Pipe Thawing Units

General Safety Information

WARNING! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire, and/or serious personal injury.

SAVE THESE INSTRUCTIONS!

Work Area Safety

Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.

Do not operate these tools in explosive atmo- spheres, such as in the presence of flammable liquids, gases, or dust. Electrical switches may create sparks which may ignite dust or fumes.

Keep bystanders, children, and visitors away while operating a Pipe Thawing Unit. Distractions can cause you to lose control.

Electrical Safety

Grounded tools must be plugged into an outlet, properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the out- let is properly grounded. If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user.

Cover of

grounded outlet box

Grounding prong

 

Grounding prong

Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electrical shock if your body is grounded.

Do not expose power tools to rain or wet condi- tions. Water entering an electrical tool will increase the risk of electrical shock.

Do not abuse cord. Never use the cord to carry the tools or pull the plug from an outlet. Keep cord away from heat, oil, sharp edges, or moving parts. Replace damaged cords immediately. Damaged cords increase the risk of electrical shock.

When operating an electrical tool outside, use an outdoor extension cord marked “W-A” or “W”.

These cords are rated for outdoor use and reduce the risk of electrical shock.

Use only three-wire extension cords which have three-prong grounding plugs, and three-pole re- ceptacles which accept the tools plug. Use of other extension cords will not ground the tool and increases the risk of electrical shock.

Use proper extension cords. (See chart.) Insufficient conductor size will cause excessive voltage drop, loss of power, and overheating.

Minimum Wire Gauge for Cord Set

Total Length (in feet)

0 – 25

14 AWG

26 – 50

12 AWG

Over 50 ft.

NOT RECOMMENDED

Keep all electric connections dry and off the ground. Do not touch plugs or tool with wet hands. Reduces the risk of electrical shock.

Personal Safety

Stay alert, watch what you are doing and use com- mon sense when operating a tool. Do not use tool while tired or under the influence of drugs, alcohol or medications. A moment of inattention while oper- ating tools may result in serious personal injury.

Avoid accidental starting. Be sure switch is OFF before plugging in. Plugging in machines that have the switch ON invites accidents.

Do not over-reach. Keep proper footing and bal- ance at all times. Proper footing and balance enables better control of the tool in unexpected situations.

Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes, hard hat, or hear- ing protection must be used for appropriate conditions.

Tool Use and Care

Do not use tool if switch does not turn it ON or OFF. Any tool that cannot be controlled with the switch is dangerous and must be repaired.

Store idle tools out of the reach of children and other untrained persons. Tools are dangerous in the hands of untrained users.

Maintain tools with care. Properly maintained tools are less likely to cause injury.

Check for breakage of parts, and any other condition that may affect the tool’s operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools.

2

Ridge Tool Company

Image 4
Contents Pipe Thawing Units Table of Contents KT-190 and KT-200 Pipe Thawing Units General Safety Information Work Area SafetyElectrical Safety Personal SafetySpecific Safety Information Description and SpecificationsProblem Diagnostics Tool Assembly Installing Cables with ClampsTool Inspection Tool Set-UpOperating Instructions Thawing Tap Water LinesTool Removal Thawing Frozen Hydronic Systems Single Zone SystemSpecial Applications Procedure Multi-Zone SystemIsolating Multi-Zone Systems Increasing Thawing Capacity on KT-200 OnlyMaintenance Instructions Tool MaintenanceTool Storage Parallel OperationService and Repair Electrical SchematicsKT-190 Thawer 115V/60Hz KT-200 ThawerDescongeladoras de tuberías KT-190 y KT-200 Índice Información general de seguridad Seguridad en la zona de trabajoSeguridad eléctrica Seguridad personalInformación específica de seguridad Uso y cuidado de la máquinaServicio Seguridad de la Descongeladora de tuberíasDiagnóstico de problemas Descripción y especificacionesEn tuberías domiciliarias de agua potable Ensamblaje de la máquinaInstalación del cable con pinza Inspección de la Descongeladora Preparación de la máquinaInstrucciones de funcionamiento Descongelación de tuberías domiciliarias de agua potableDescongelación de redes hidrónicas congeladas Extracción de la DescongeladoraRed de zona única Red multizonal Cómo aislar una red multizonalFuncionamiento en serie Procedimiento para métodos especialesFuncionamiento en paralelo Instrucciones de mantenimiento Almacenamiento de la máquinaServicio y reparaciones Mantenimiento de la máquinaDescongeladora KT-190 115V/60Hz Esquemas eléctricosDescongeladora KT-200 Descongeladoras de tuberías KT-190 y KT-200 Ridge Tool Company