Model KT-190 and KT-200 Pipe Thawing Units

6.When plugging the Pipe Thawing Tool into the elec- trical outlet, making sure to position the power cord along the clear path selected earlier. If the power cord does not reach the outlet, use an extension cord in good condition.

WARNING To avoid electric shock and electrical fires, never use an extension cord that is damaged or does not meet the following requirements:

The cord has a three-prong plug similar to shown in Electrical Safety section.

The cord is rated as “W” or “W-A” if being used out- doors.

The cord has sufficient wire thickness (14 AWG below 25/12 AWG 25- 50). If the wire thickness is too small, the cord may overheat, melting the cord’s insulation or causing nearby objects to ignite.

WARNING To reduce risk of electrical shock, keep all electrical connections dry and off the ground. Do not touch plug with wet hands.

Operating Instructions

WARNING

To reduce risk of electrical shock, keep all electri- cal connections dry and off the ground. Do not touch plug with wet hands.

Be very careful when thawing frozen pipes. Clamp tips and cable connections become hot during use. Avoid contact with skin as burns can result.

Keep clamps away from combustible materials or articles that can be damaged by heat.

Do not leave the unit unattended while thawing.

Thawing Tap Water Lines

NOTE! It is recommended that there be standard water pressure on one side of the frozen section of pipe and an open faucet on the other side of the frozen section (Figure 4). As the pipe warms to above freezing point, the water, with pressure behind it, will seep along the inside walls melting and flushing the remaining ice out of the faucet.

1.Make sure unit is unplugged and turned OFF and cables are completely uncoiled.

2.Place one clamp on each side of the frozen section of pipe. Open the faucet where no water flows.

WARNING Making pipe connections before plug- ging in unit prevents arcing between clamps and pipe.

3.Plug unit into a grounded 15 amp outlet making sure to position the power cord along the clear path se- lected earlier.

4.Move switch to ON (up position on KT-190. Center switch down to low position, left switch to A on KT-200).

5.If current is below 15 amps on KT-200, switch to B. If current is still below 15 amps, switch to high position on center switch and right switch up to C.

6.Continue until 15 amps is reached but not exceeded, D switch setting is used with long runs.

Thawing time may vary from a few seconds to several hours depending on length and diameter of pipe being thawed. If time seems unreasonable, check clamps for proper placement.

Kitchen Sink

Bathroom Sink

Frozen Section

Figure 4 – Thawing Tap Water Lines

6

Ridge Tool Company

Image 8
Contents Pipe Thawing Units Table of Contents KT-190 and KT-200 Pipe Thawing Units General Safety Information Work Area SafetyElectrical Safety Personal SafetySpecific Safety Information Description and SpecificationsProblem Diagnostics Tool Assembly Installing Cables with ClampsTool Inspection Tool Set-UpOperating Instructions Thawing Tap Water LinesTool Removal Thawing Frozen Hydronic Systems Single Zone SystemSpecial Applications Procedure Multi-Zone SystemIsolating Multi-Zone Systems Increasing Thawing Capacity on KT-200 OnlyMaintenance Instructions Tool MaintenanceTool Storage Parallel OperationService and Repair Electrical SchematicsKT-190 Thawer 115V/60Hz KT-200 ThawerDescongeladoras de tuberías KT-190 y KT-200 Índice Información general de seguridad Seguridad en la zona de trabajoSeguridad eléctrica Seguridad personalInformación específica de seguridad Uso y cuidado de la máquinaServicio Seguridad de la Descongeladora de tuberíasDiagnóstico de problemas Descripción y especificacionesInstalación del cable con pinza Ensamblaje de la máquinaEn tuberías domiciliarias de agua potable Inspección de la Descongeladora Preparación de la máquinaInstrucciones de funcionamiento Descongelación de tuberías domiciliarias de agua potableRed de zona única Extracción de la DescongeladoraDescongelación de redes hidrónicas congeladas Red multizonal Cómo aislar una red multizonalFuncionamiento en paralelo Procedimiento para métodos especialesFuncionamiento en serie Instrucciones de mantenimiento Almacenamiento de la máquinaServicio y reparaciones Mantenimiento de la máquinaDescongeladora KT-200 Esquemas eléctricosDescongeladora KT-190 115V/60Hz Descongeladoras de tuberías KT-190 y KT-200 Ridge Tool Company