RIDGID kt-190 manual Specific Safety Information, Description and Specifications

Page 5

Model KT-190 and KT-200 Pipe Thawing Units

Use only accessories that are recommended by the manufacturer for your tool. Accessories that may be suitable for one tool may become hazardous when used on another tool.

Inspect tool and extension cords periodically and replace if damaged. Damaged cords increase the risk of electrical shock.

Keep handles dry and clean; free from oil and grease. Allows for better control of the tool.

Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the unit. These preventative safety measures reduce the risk of accidentally starting the unit.

Service

Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified repair personnel could result in injury.

When servicing a tool, use only identical replace- ment parts. Follow instructions in the Maintenance Section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electrical shock or injury.

Disconnect all power from the unit before servic- ing. Eliminates the risk of electrical shock and accidental starting.

Specific Safety Information

WARNING

Read this operator’s manual carefully before using the Pipe Thawing Tools. Failure to understand and follow the contents of this manual may result in electrical shock, fire and/or serious personal injury.

Call the Ridge Tool Company, Technical Service Depart- ment at (800) 519-3456 if you have any questions.

Tool Safety

Tool is made to thaw frozen iron or copper water pipes. Follow the instructions on proper use. Other uses may increase the risk of injury.

Do not leave the unit unattended while thawing. Such preventive measures reduce the risk of injury or fire.

Do not touch the clamp tips or cable connections. Reduces the risk of burns.

Do not operate unit with housing removed. Exposure to internal parts may result in injury.

Make both pipe connections before plugging in unit. Prevents electrical arcing between the clamps and the pipe.

Use cable and clamps provided with unit. Incorrect cables may result in overheating of the wires.

Keep clamps away from combustible materials or articles that can be damaged by heat. Clamp tips be- come hot during use.

Description and Specifications:

Description

The RIDGID Pipe Thawing Machines are easy-to-use, and versatile for thawing 1/2to 11/2copper or steel/iron pipe up to 150 feet (KT-200). Both the KT-190 and KT-200 use low voltage and high amperage to quickly thaw frozen tap water lines and frozen heating systems.

This method does not require that you know exactly where the frozen section is nor do you have to have direct access to the area. The KT-190 and KT-200 will thaw cop- per or steel pipe that is underground, beneath the floor or behind walls. Multiple voltage settings on the KT-200 allow for maximum amperage to provide the shortest thawing time. Vinyl coated clamps with 25 foot cables, standard with both units, permit thawing of a 50section of pipe. Additional 25cable extensions are available for longer runs.

Specifications

Line Capacity:

Primarily recommended for all indoor copper or steel pipes from 1/2to 11/2. Thawing units will not work with plastic pipe or lines containing plastic or rubber couplings.

Thawing Unit:

 

 

Input

115 Volts,

15 Amps

 

KT-190

KT-200

Output

6.0 Volts

4.5 - 7.6 Volts

Output

300 Amps

300 Amps

Minimum Reach

15

4

Maximum Reach

75

150

Weight

25 lbs

29 lbs

Weight

11.4 kgs

13.2 kgs

Ridge Tool Company

3

Image 5 Contents
Pipe Thawing Units Table of Contents KT-190 and KT-200 Pipe Thawing Units Work Area Safety General Safety InformationElectrical Safety Personal SafetyDescription and Specifications Specific Safety InformationProblem Diagnostics Installing Cables with Clamps Tool AssemblyTool Inspection Tool Set-UpThawing Tap Water Lines Operating InstructionsThawing Frozen Hydronic Systems Single Zone System Tool RemovalMulti-Zone System Special Applications ProcedureIsolating Multi-Zone Systems Increasing Thawing Capacity on KT-200 OnlyTool Maintenance Maintenance InstructionsTool Storage Parallel OperationElectrical Schematics Service and RepairKT-190 Thawer 115V/60Hz KT-200 ThawerDescongeladoras de tuberías KT-190 y KT-200 Índice Seguridad en la zona de trabajo Información general de seguridadSeguridad eléctrica Seguridad personalUso y cuidado de la máquina Información específica de seguridadServicio Seguridad de la Descongeladora de tuberíasDescripción y especificaciones Diagnóstico de problemasInstalación del cable con pinza Ensamblaje de la máquinaEn tuberías domiciliarias de agua potable Preparación de la máquina Inspección de la DescongeladoraDescongelación de tuberías domiciliarias de agua potable Instrucciones de funcionamientoRed de zona única Extracción de la DescongeladoraDescongelación de redes hidrónicas congeladas Cómo aislar una red multizonal Red multizonalFuncionamiento en paralelo Procedimiento para métodos especialesFuncionamiento en serie Almacenamiento de la máquina Instrucciones de mantenimientoServicio y reparaciones Mantenimiento de la máquinaDescongeladora KT-200 Esquemas eléctricosDescongeladora KT-190 115V/60Hz Descongeladoras de tuberías KT-190 y KT-200 Ridge Tool Company
Related manuals
Manual 27 pages 45.21 Kb