Simrad SIMRAD HS50 manual Bracket mounting option

Page 24

Simrad HS50 Heading Sensor

Bracket mounting (option)

An optional bracket, part no. 22084941, may be ordered from

Simrad.

Note!When the Display unit is bracket-mounted, it is not weatherproof from the back due to a breathing hole in the back cabinet. When bracket-mounted, the exposed parts of the plugs should be protected against salt corrosion.

1Locate the cradle on the mounting site and mark the 4 holes for the screws on the mounting surface.

2Drill the 4 holes and screw the cradle to the mounting surface.

3Remove the front panel corners, and use the supplied screws to fasten the Display unit to the left and right brackets.

4Apply the front panel corners.

5Use the two locking knobs to assemble the cradle with the left and right brackets and adjust the Display unit for the best viewing angle.

6Connect the cable from the Processing unit to the Display unit connector.

16

20221081 / F

Image 24
Contents Simrad HS50 Heading Sensor Copyright 20221081 / F Document revisions Contents Operating Instructions Figures and Drawings This page Intentially Left Blank Introduction HS50 System components20221081 / F About this manual Definitions, abbreviations and acronymsDefinitions Abbreviations and acronyms NmeaHealth, environment and safety Restrictions in guaranteeRestrictions in use Physical dimensions Performance dataSensor unit Display unitPower Environmental specificationProcessing unit Cable InterfaceProcessing unit to sensor unit cable General Cable connectionGrounding Sensor unit Location of the unitMechanical installation Bracket mounting option Cable wiring Pedestal mounting optionWaterproofing the connectors Display unitPanel mounting Alternative panel mountingBracket mounting option Display unit cable Processing unit Cable connections Display Unit Sensor Unit Connecting to Simrad equipment RGC Signal Interface unitAP9MK3 Autopilot J50/J300X Junction unit NI300XIS15 Instruments RGC12 Gyro Compass Simrad RA40/RA50 RadarSoftware setup procedure Display Adjustments ExampleDifferential corrections Data output All six serial lines may be used simultaneouslyEthernet GeneralHeight aiding Velocity filteringRadar format DatumExpert setup HDT-QRun mode Heading offsetExample Operating Instructions OverviewTurning the system ON/OFF Performance monitoring348 Navigation/HDT display Navigation/POS displayInfo displays Hdop PdopGps hdt Deviation Accuracy Last heading Common sat Alarms Invalid Position alarm Invalid Heading alarmInvalid Position and Heading alarm Operation Height aided GPS positionThis page Intentially Left Blank Maintenance Periodic maintenanceSoftware upgrades Re-calibration of the Sensor unitTroubleshooting Repairs and modificationsReplacing damaged cables Replacing damaged unitsNo response No valid dataNo Differential corrections Invalid HeadingReduced heading indication Simulated dataFigures and Drawings Dimensions SeatexSensor unit bracket, dimensions Kongsberg SeatexSensor unit Processing unit, dimensions Display unit, dimensions Standard delivery Optional equipmentDocumentation