Simrad HS50 Heading Sensor
The average value for observations from each of the two different systems should then be used, and the offset between the two systems (reference value minus HS50 reading) input as the Head offset value.
The offset value can be either positive or negative.
Example:
If the heading measured by the reference system is 32.1° and the HS50 heading 28.5° during the calibration period, 3.6 (32.1 - 28.5) should be entered in the General submenu as the Head offset value.