Simrad SIMRAD HS50 manual Display Unit Sensor Unit

Page 28

Simrad HS50 Heading Sensor

The pinout for each terminal is as follows:

P200

P201

J60

P80

P202

P203

P204

P205

P206

P207

P208

P300

DISPLAY UNIT

SENSOR UNIT

Ethernet

DATA

OUT 1

DATA

OUT 1

DATA

OUT 2

DIFF

INPUT

DIFF INPUT

RADAR

POWER

ALARM

GREEN

POWC

YELLOW

GND

GREY

PWR

PINK

BUS+

WHITE

BUS-

BROWN

 

GND

SHIELD

 

COMM +

4

 

COMM -

3

 

PWR+

2

 

PWR-

1

 

RJ45

 

 

 

 

 

 

 

 

 

 

NOT USED

 

 

 

 

 

 

 

 

 

 

 

 

232 OUT

 

 

422- OUT

 

 

422+ OUT

 

 

GND_A

 

232 OUT

 

422- OUT

 

422+ OUT

 

GND_B

 

 

232 OUT

 

 

422- OUT

 

 

422+ OUT

 

 

GND_C

 

422+ IN

 

422- IN

 

 

 

 

 

 

 

 

 

 

 

232 IN

 

 

GND_D

 

NOT

 

USED

 

 

AD10_C

 

 

AD10_D

 

 

AD10_GND

 

SHIELD

 

PWR_+

 

PWR_GND

 

20

20221081 / F

Image 28
Contents Simrad HS50 Heading Sensor Copyright 20221081 / F Document revisions Contents Operating Instructions Figures and Drawings This page Intentially Left Blank Introduction HS50 System components20221081 / F Definitions, abbreviations and acronyms About this manualDefinitions Abbreviations and acronyms NmeaRestrictions in guarantee Health, environment and safetyRestrictions in use Physical dimensions Performance dataSensor unit Display unitEnvironmental specification PowerProcessing unit Interface CableProcessing unit to sensor unit cable Cable connection GeneralGrounding Sensor unit Location of the unitMechanical installation Bracket mounting option Cable wiring Pedestal mounting optionWaterproofing the connectors Display unitPanel mounting Alternative panel mountingBracket mounting option Display unit cable Processing unit Cable connections Display Unit Sensor Unit RGC Signal Interface unit Connecting to Simrad equipmentAP9MK3 Autopilot NI300X J50/J300X Junction unitIS15 Instruments RGC12 Gyro Compass Simrad RA40/RA50 RadarSoftware setup procedure Display Adjustments ExampleDifferential corrections Data output All six serial lines may be used simultaneouslyEthernet GeneralHeight aiding Velocity filteringRadar format DatumExpert setup HDT-QRun mode Heading offsetExample Operating Instructions OverviewTurning the system ON/OFF Performance monitoring348 Navigation/HDT display Navigation/POS displayInfo displays Hdop PdopGps hdt Deviation Accuracy Last heading Common sat Alarms Invalid Heading alarm Invalid Position alarmInvalid Position and Heading alarm Operation Height aided GPS positionThis page Intentially Left Blank Maintenance Periodic maintenanceSoftware upgrades Re-calibration of the Sensor unitTroubleshooting Repairs and modificationsReplacing damaged cables Replacing damaged unitsNo response No valid dataNo Differential corrections Invalid HeadingReduced heading indication Simulated dataFigures and Drawings Dimensions SeatexSensor unit bracket, dimensions Kongsberg SeatexSensor unit Processing unit, dimensions Display unit, dimensions Optional equipment Standard deliveryDocumentation